6. Capacity compensation rate for pipe length and height
difference
Height difference H
Indoor unit is higher than outdoor unit
*
1
Indoor unit is lower than outdoor unit
*
2
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
6-1. Model: AOHG30KMTA
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
20
30
40
50
Height difference H (m)
Indoor unit is higher
than outdoor unit *1
30
—
—
—
—
0.926
0.916
0.906
20
—
—
—
0.953
0.942
0.931
0.920
10
—
—
0.979
0.968
0.958
0.946
0.936
7.5
—
0.988
0.983
0.972
0.961
0.951
0.939
5
0.992
0.992
0.987
0.976
0.965
0.954
0.943
0
1.000
1.000
0.995
0.984
0.973
0.962
0.951
Indoor unit is lower than
outdoor unit *2
-5
1.000
1.000
0.995
0.984
0.973
0.962
0.951
-7.5
—
1.000
0.995
0.984
0.973
0.962
0.951
-10
—
—
0.995
0.984
0.973
0.962
0.951
-20
—
—
—
0.984
0.973
0.962
0.951
-30
—
—
—
—
0.973
0.962
0.951
HEATING
Pipe length (m)
5
7.5
10
20
30
40
50
Height difference H (m)
Indoor unit is higher
than outdoor unit *1
30
—
—
—
—
0.931
0.914
0.899
20
—
—
—
0.954
0.931
0.914
0.899
10
—
—
0.990
0.954
0.931
0.914
0.899
7.5
—
1.000
0.990
0.954
0.931
0.914
0.899
5
1.000
1.000
0.990
0.954
0.931
0.914
0.899
0
1.000
1.000
0.990
0.954
0.931
0.914
0.899
Indoor unit is lower than
outdoor unit *2
-5
0.995
0.995
0.986
0.949
0.926
0.909
0.895
-7.5
—
0.993
0.983
0.946
0.924
0.907
0.892
-10
—
—
0.981
0.944
0.921
0.904
0.890
-20
—
—
—
0.935
0.912
0.895
0.881
-30
—
—
—
—
0.903
0.886
0.872
- 43 -
6-1. Model: AOHG30KMTA
6. Capacity compensation rate for pipe length and height difference
OUTDOOR UNIT
AOHG30-36KMTA
OUTDOOR UNIT
AOHG30-36KMTA