1. Specifications
Type
Wall mounted
Inverter heat pump
Model name
ASHG09KMCDN
ASHG12KMCDN
ASHG14KMCDN
Power supply
230 V ~ 50 Hz
Available voltage range
198—264 V
Capacity
Cooling
Rated
kW
2.50
3.40
4.20
Btu/h
8,500
11,600
14,300
Min.—Max.
kW
1.0—3.8
1.0—4.2
1.2—4.65
Btu/h
3,400—13,000
3,400—14,300
4,100—15,900
Heating
Rated
kW
3.20
4.00
5.40
Btu/h
10,900
13,600
18,400
Min.—Max.
kW
0.9—5.7
0.9—5.9
0.9—6.4
Btu/h
3,100—19,400
3,100—20,100
3,100—20,400
Input power
Cooling
Rated
kW
0.540
0.800
1.100
Min.—Max.
0.21—1.08
0.21—1.25
0.26—1.25
Heating
Rated
0.720
0.960
1.400
Min.—Max.
0.18—2.35
0.18—1.8
0.185—1.9
Current
Cooling
Rated
A
2.5
3.6
4.9
Heating
3.3
4.3
6.2
EER
Cooling
kW/kW
4.63
4.25
3.82
COP
Heating
4.44
4.17
3.86
Sensible capacity
Cooling
kW
2.37
2.74
3.26
Power factor
Cooling
%
94
96
97
Heating
95
97
98
Moisture removal
L/h (pints/h)
1.3 (2.3)
1.8 (3.2)
2.1 (3.7)
Maximum operating current *1
Cooling
A
6.0
7.0
8.5
Heating
9.5
11.5
16.0
Fan
Airflow rate
Cooling
HIGH
m
3
/h
670
690
770
MED
530
560
600
LOW
410
450
450
QUIET
280
280
280
Heating
HIGH
750
780
820
MED
620
630
650
LOW
510
520
520
QUIET
290
290
340
Type × Q'ty
Crossflow fan × 1
Motor output
W
27
Sound pressure level *2
Cooling
HIGH
dB (A)
40
42
43
MED
36
37
40
LOW
30
32
33
QUIET
20
20
20
Heating
HIGH
42
43
44
MED
38
39
40
LOW
33
35
35
QUIET
22
22
24
Heat exchanger type
Dimensions (H × W × D)
mm
Main1: 210 × 670 × 26.6
Main2: 112 × 670 × 20
Sub1: 84 × 670 × 13.3
Fin pitch
Man1: 1.2, Main2: 1.1, Sub1:1.4
Rows × Stages
Main1: 2 × 10, Main2: 2 × 7, Sub:1 × 4
Pipe type
Copper tube
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White + Pearl white (painted)
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net
mm
270 × 834 × 215
Gross
277 × 914 × 332
Weight
Net
kg
10.0
Gross
13.0
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas
Ø 9.52 (Ø 3/8)
Method
Flare
Drain hose
Material
PP+HDPE
Tip diameter
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller type
Wireless (Wired, Mobile app*3 [FGLair
™
] [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play
™
store or on App Store
®
. WLAN adapter is also required. For details, refer to the setting manual.
- 2 -
1. Specifications
WALL MOUNTED
ASHG09-14KMCDN
WALL MOUNTED
ASHG09-14KMCDN