background image

6.

Select the [Function No.] with pressing the [Cursor button (Left/Right)], and select the Func-
tion No. to be set with pressing the [Cursor button (Up/Down)].

Cancel:                              OK: 

Function setting                               

Mo 10:00

   R.C.                Function          Setting
  address        No.                No.

 Version                        Error history

00

         

  

00

          00

7.

Select the [Setting No.] with pressing the [Cursor button (Left/Right)], and select the Setting
No. to be set with pressing the [Cursor button (Up/Down)],and press the [Enter button].

Cancel:                              OK: 

Function setting                               

Mo 10:00

   R.C.                Function          Setting
  address        No.                No.

 Version                        Error history

00

     

      00          

00

DESIGN & TECHNICAL MANUAL

- 24 -

ZONE CONTROL

SYSTEM

Содержание FGLair

Страница 1: ...NAL PART Zone control system DESIGN TECHNICAL MANUAL ZONE CONTROL INTERFACE UTY CDPXZC UTY CDPXZD WIRED REMOTE CONTROLLER WIRELESS LAN ADAPTER MOBILE APP UTY RVNYN UTY TFNXZ3 FGLair DR_OP002EF_06 2016 11 28 ...

Страница 2: ...m and logo are trademarks of Fujitsu General Limited in the United States other countries or both FGLair Android and Google Play are trademarks of Google Inc App Store is a service mark of Apple Inc registered in the U S and other countries IOS is a trademark or registered trademark of Cisco in the U S and other countries and is used under license Copyright 2016 Limited All rights reserved ...

Страница 3: ...rol Interface 8 5 Wiring design 10 5 1 System diagram 10 6 Installation 11 6 1 Wired remote controller 11 6 2 Zone control interface 15 7 Function settings 22 7 1 Function settings on wired remote controller 22 7 2 Function settings by using remote controller 23 8 Accessories 29 8 1 Wired remote controller 29 8 2 Zone control interface 29 9 Optional parts 30 9 1 Zone control interface 30 ...

Страница 4: ...2 Zone Control Interface 39 5 Wiring design 41 5 1 System diagram 41 6 Installation 42 6 1 Wireless LAN adapter 42 6 2 Zone control interface 44 7 Initial setup 52 7 1 Mobile app installation and user registration 52 7 2 Air conditioner registration 52 7 3 Zone control 52 8 Accessories 53 8 1 Wireless LAN adapter 53 8 2 Zone control interface 53 9 Optional parts 54 9 1 Zone control interface 54 CO...

Страница 5: ...Part 1 ZONE CONTROL SYSTEM MODEL NAME WIRED REMOTE CONTROLLER UTY RVNYN ZONE CONTROL INTERFACE UTY CDPXZC UTY CDPXZD ...

Страница 6: ...XZD UTY RNNYN UTY RVNYN UTY RNRYZ1 UTY TWRX 1 UTY XWNX 2 UTY RSNYN UTY XWNX Wall Mounted UTY XWZX UTY RSNYN UTY RNNYN UTY RVNYN UTR DPB24T UTR STA UTR DPB24T For Others Demand control option PCB Half Concealed Kit For Cassette type only Wide Panel Cassette Grille Drain Pump Unit Insulation Kit for High Humidity Panel Spacer Air Outlet Shutter Plate UTY XWZX UTY RNNYN UTY RNNYN UTY RSNYN UTY XWZX U...

Страница 7: ...2 Model lineup Wired remote controller Zone control interface UTY RVNYN UTY CDPXZC UTY CDPXZD 3 ZONE CONTROL SYSTEM ...

Страница 8: ...r option Indoor unit Zone Control Interface Wired Remote Controller Damper locally purchased This system controls the individual air flow to each zone by opening and closing the damper in stalled at the blowing side of high static pressure duct High static pressure duct Damper locally purchased Remote Sensor unit option Wired Remote Controller Zone Control Interface 4 ZONE CONTROL SYSTEM ...

Страница 9: ...ler a b c d e f g h i a Display panel with backlight b Screen switch button Left c Menu button d Cancel button e Cursor button f Screen switch button Right g Power indicator h On off button i Enter button 5 ZONE CONTROL SYSTEM ...

Страница 10: ... Error history Key lock Operation mode exemption Management password Zone setting Zone setting on off Room temperature sensor setting Zone group setting day night all Name setting zone sensor group Available Not available 1 Indoor unit on off temperature and open close can be set up to 8 times day by weekly timer Since the weekly timer can set the schedule for 2 weeks different setting can be used...

Страница 11: ...5 3 63 5 83 5 23 9 4 5 33 5 Unit mm Size H W D mm 120 120 21 3 Weight g 220 Wiring specifications Use Size Wire type Remarks Remote controller cable 0 33 mm2 22AWG Polar 3 core Use shielded cable locally purchased in accordance with the regional cable standard 7 ZONE CONTROL SYSTEM ...

Страница 12: ...face Unit mm Model name UTY CDPXZC UTY CDPXZD Power supply 240 V 50 Hz Damper 24 V 50 Hz 240 V 50 Hz Zone 1 to 8 Dimensions H W D Net mm 316 234 126 Gross mm 410 285 205 Weight Net kg 2 1 2 3 Gross 3 0 8 ZONE CONTROL SYSTEM ...

Страница 13: ...t per a damper mA 360 or less 70 or less Maximum electric power per a damper VA 7 or less 12 or less Damper motor cable Wire diameter mm2 0 48 or more 0 75 Type RJ12 6 polar 6 core Type 60227 IEC52 or 53 Transformer locally purchased Transformer Specification UTY CDPXZC 24 V Select an appropriate transformer for the damper specification 9 ZONE CONTROL SYSTEM ...

Страница 14: ...ers 1 remote controller 2 remote controllers Zone control Interface A B and C Remote controller cable Prohibited uses UTY RVNYN AR WAF AR 6TC AR 3TA Accessory UTY RVNYN UTY RSNYN SET TEMP START STOP Zone control interface Zone control interface UTY RVNYN UTY LRHYM Zone control interface Indoor unit Arbitrary character 10 ZONE CONTROL SYSTEM ...

Страница 15: ...ard pats directly with your hands Otherwise in jury or electric shock could result Be careful so that the front case does not fall after the front case are removed Otherwise a damage of the front case could result To avoid incoming water or insects along the cable always establish a trap and seal the wiring hole Overtighten of the screws may cause a distortion or a damage of the rear case Do not m...

Страница 16: ...hite 3 COM black 25 8 8 8 10 c Connect the functional earthing wire of remote controller and the remote controller cable and perform the insulation Cable tie large Remote controller cable Wrap the connector and remote controller cables with vinyl tape or some other type of insulation as shown in the figure Tube Remote controller Functional earthing wire 2 Remove the front case Insert the flat blad...

Страница 17: ...eal the wiring hole of the remote controller cable b Put a remote controller cable through the back hole of the rear case of the main body c Fix the rear case by securing if with attached screws 2 places Screws Wall Trap Trap Putty Rear case Seal the wiring hole of the remote controller cable with putty When routing the cable on the wall a Cut off the cable guide of the front case with using a kni...

Страница 18: ...nsion or pressure to the terminal block fix the remote controller cable with the cable tie properly CAUTION Be carefull to avoid breaking the cable by over tightening the cable tie When connecting the remote controller cables do not over tightening the screws 5 Attach the front case Insert after adjusting upper part of front case When insert the front case do not pinch the cable PROHIBITED GOOD Fr...

Страница 19: ...r unit Control box Service space Zone control interface 35 or more 450 or more Attic Unit mm Indoor unit Service space 35 or more Zone control interface 500 or more Attic Unit mm Zone control interface Indoor unit ART 30 36 ART 72 90 ART 45 54 60 Control box Installation procedure Installation to indoor unit 1 Remove the cover of zone control interface Screws 2 Attach the zone control interface to...

Страница 20: ...e accessory Cable tie small accessory Indoor unit Cable tie small accessory 2 Connecting with remote controller Cable tie accessory Remote cable controller small Red White Black Functional earth ground wire Junction box locally purchased Up to 2 more controllers can be When you install 2 remote controllers use junction box 16 ZONE CONTROL SYSTEM ...

Страница 21: ...e tie Tighten 2 cables accessory Cable tie small Damper cables Transformer Power supply cable for dampers accessory Cable tie small PIN PIN 1 and 2 PIN 3 and 4 PIN 5 and 6 Descriptions OPEN COMMON CLOSE 4 Connecting with power supply earth ground wire Protective cable Power supply Cable clamp 17 ZONE CONTROL SYSTEM ...

Страница 22: ...ng with optional remote sensor Remote sensor cables Indoor unit accessory Cable tie small CN8 black CN7 white sensor Remote accessory Cable tie small accessory Cable tie small sensor Remote 18 ZONE CONTROL SYSTEM ...

Страница 23: ...unit Zone control interface connecting cable CN6 2 Connecting with remote controller Up to 2 more controllers can be installed When you install 2 remote controllers use junction box Junction box locally purchased Cable tie accessory small Remote cable controller Red White Black Functional earth ground wire 19 ZONE CONTROL SYSTEM ...

Страница 24: ... supply for dampers accessory Cable tie small Tighten 2 cables with a Cable tie small Damper cables OPEN COMMON CLOSE 4 Connecting with power supply Power supply cable Cable clamp Protective earth ground wire 20 ZONE CONTROL SYSTEM ...

Страница 25: ...ote sensor accessory Cable tie small accessory Cable tie small accessory Cable tie small Indoor unit Zone control interface connecting cable CN7 white CN8 black Remote sensor Remote sensor Remote sensor cable 21 ZONE CONTROL SYSTEM ...

Страница 26: ...tion settings are located as shown in the following figure DIP switch setting SW1 Memory backup setting Set to ON to use the batteries for memory backup If the batteries are not used all of the settings stored in the memory will be deleted if there is power failure NOTE In case of simple remote controller DO NOT turn it on SW1 Memory backup Factory setting OFF Disable ON Enable SW2 Dual remote con...

Страница 27: ... returns to the Monitor screen Back Setting Date and time Submenu 1 2 Monitor Screen Filter sign R C sensor control Room temp display Off Off Mo 10 00 3 Press the Screen switch button Left and Screen switch button Right simultaneously for 5 seconds to switch to Service screen Back Setting Service Mo 10 00 Function setting Error history I U address verification Version Test run 4 Select Function se...

Страница 28: ...ng Mo 10 00 R C Function Setting address No No Version Error history 00 00 00 7 Select the Setting No with pressing the Cursor button Left Right and select the Setting No to be set with pressing the Cursor button Up Down and press the Enter button Cancel OK Function setting Mo 10 00 R C Function Setting address No No Version Error history 00 00 00 24 ZONE CONTROL SYSTEM ...

Страница 29: ...tting screen Back Setting R C function setting Mo 7 07 PM Set temp range Initial Room temp correction Operation mode exemption Operation mode exemption The specified operation mode can be removed from the operation mode menu of the wired remote controller This does not mean that the operation mode is exempted from the indoor unit Check the operation modes you want to exempt NOTES In the case of du...

Страница 30: ...mary unit and the secondary unit setting same Even if only the primary unit is set it will not be reflected at secondary unit After setting always perform operation Since the indoor unit memorizes the last opera tion overwriting the memory operation mode is unnecessary Room temp correction The value sensed by the temperature sensor listed in the wired remote controller can be cor rected Set the co...

Страница 31: ... number of outlet NOTE Install the outlets so that air velocity of each outlet is same value Damper type setting When spring return damper is used indoor unit starts operating 1 minute after the damper opens Set when you use spring return damper NOTE Do not start the operation by external input of indoor unit 27 ZONE CONTROL SYSTEM ...

Страница 32: ... of op sensor Set when you use optional sensor Temperature sensor setting Set whether to use temperature sensor of the remote controller Zone function setting Adjust temperature of optional sensor 28 ZONE CONTROL SYSTEM ...

Страница 33: ...on manual 1 Cable tie small 1 Connecting cable 1 Tube 1 Tapping screw M4 16 mm 2 Cable clamper 1 Tapping screw M4 14 mm 1 8 2 Zone control interface Part name Exterior Q ty Part name Exterior Q ty Installation manual 1 Tapping screw M4 12 mm 3 Connecting cable 1 Cable tie small 9 One touch bush 3 Cable tie large 1 29 ZONE CONTROL SYSTEM ...

Страница 34: ...parts 9 1 Zone control interface Exterior Part name Model name Summary Remote sensor unit UTY XSZX New amenity space can be offered by installing Remote sensor unit in the remote controller 30 ZONE CONTROL SYSTEM ...

Страница 35: ...Part 2 ZONE CONTROL SYSTEM with WLAN ADAPTER MODEL NAME WIRELESS LAN ADAPTER UTY TFNXZ3 MOBILE APPLICATION FGLair ZONE CONTROL INTERFACE UTY CDPXZC UTY CDPXZD ...

Страница 36: ...RNNYN UTY RVNYN UTY RNRYZ1 UTY TWRX 1 UTY XWNX 2 UTY RSNYN UTY XWNX Wall Mounted UTY XWZX UTY RSNYN UTY RNNYN UTY RVNYN UTR DPB24T UTR STA UTR DPB24T For Others Demand control option PCB Half Concealed Kit For Cassette type only Wide Panel Cassette Grille Drain Pump Unit Insulation Kit for High Humidity Panel Spacer Air Outlet Shutter Plate UTY XWZX UTY RNNYN UTY RNNYN UTY RSNYN UTY XWZX UTY XWZX ...

Страница 37: ...2 Model lineup Wireless LAN adapter Mobile application Zone control interface UTY TFNXZ3 FGLair UTY CDPXZC UTY CDPXZD 33 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 38: ...tion Indoor unit Zone Control Interface Wired Remote Controller Damper locally purchased This system controls the individual air flow to each zone by opening and closing the damper in stalled at the blowing side of high static pressure duct High static pressure duct Damper field supply Remote Sensor unit option Zone Control Interface Wireless LAN adapter 34 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 39: ...dard Set the connection to the wireless router with WPS to perform communications by wireless LAN Refer to the operation manual of the wireless router you wish to use if it supports IEEE802 11b g n or WPS Smartphone or Tablet PC App compliant operating system iOS 8 0 or later Android 4 1 or later FGLair mobile application FGLair is available on Google Play store or on App Store After installation ...

Страница 40: ...tion setting Louver position adjustment vertical horizontal 1 Swing vertical horizontal 1 Timer setting Off timer On timer Sleep timer On off program timer Additional function ECONOMY operation setting App function Air conditioner error e mail notification Zone setting Zone setting on off Room temperature sensor setting 2 Weekly timer with zone Name setting zone sensor Available Not available 1 Di...

Страница 41: ...ess LAN status indicator c Setting button Used for connecting to wireless router Schematic diagram Indoor unit WLAN adapter Wireless LAN router Smart device Smart device Internet A Locally purchased Zone control interface A Attached cable with this product 37 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 42: ...et mm 96 38 15 Gross mm 207 138 5 50 Weight Net g 35 Gross 380 Operating temperature range C 0 to 46 Wireless specifications Communication method between indoor unit and WLAN adapter is as follows Wireless LAN standard IEEE802 11b g n Frequency bands 2 4 GHz 1ch 13ch Maximum radio frequency power 32 mW 38 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 43: ...t mm Model name UTY CDPXZC UTY CDPXZD Power supply 240 V 50 Hz Damper 24 V 50 Hz 240 V 50 Hz Zone 1 to 8 Dimensions H W D Net mm 316 234 126 Gross mm 410 285 205 Weight Net kg 2 1 2 3 Gross 3 0 39 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 44: ...damper mA 360 or less 70 or less Maximum electric power per a damper VA 7 or less 12 or less Damper motor cable Wire diameter mm2 0 48 or more 0 75 Type RJ12 6 polar 6 core Type 60227 IEC52 or 53 Transformer locally purchased Transformer Specification UTY CDPXZC 24 V Select an appropriate transformer for the damper specification 40 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 45: ...ace Outdoor unit WLAN adapter A Prohibited uses 1 Combined use with wired remote controller Zone control interface All wired remote controller 2 Extended wiring Extending the cable is prohibited Junction box Zone control interface 41 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 46: ...t install this product in following places Otherwise radio communication may be inter fered Places exposed to direct sunlight Places subject to extremely high and low temperatures such as near the outlet port of the air conditioner main body Near the air conditioner air inlet or outlet Places with high humidity Places near moving parts of the air conditioner main body Places near bottom of the air...

Страница 47: ...injure yourself Also connect the connectors securely Loose connectors will cause trouble heating fire or elec tric shock Perform wiring so that water does not inter this unit along the external wiring Always install a trap to the wiring or take other countermeasures Otherwise it will cause trouble or electric shock or fire Do not touch the circuit board and circuit board parts directly with your h...

Страница 48: ...Control box Service space Zone control interface 35 or more 450 or more Attic Unit mm Indoor unit Service space 35 or more Zone control interface 500 or more Attic Unit mm Zone control interface Indoor unit ART 30 36 ART 72 90 ART 45 54 60 Control box Installation procedure Installation to indoor unit 1 Remove the cover of zone control interface Screws 2 Attach the zone control interface to the in...

Страница 49: ...a lead wire always use a special tool such as a wire stripper If there is no special tool carefully strip off the insulation by using a knife or other utensil 1 Use ring terminals with insulating sleeves as shown in the figure to connect to the terminal block 2 Securely clamp the ring terminals to the wires by using an appropriate tool so that the wires do not come loose Strip 10 mm Ring terminal ...

Страница 50: ...ntrol interface connecting cable accessory Cable tie small accessory Indoor unit Cable tie small accessory 2 Connecting with wireless LAN adapter Cable tie accessory Wireless cable LAN adapter small Red White Black Functional earth ground wire 46 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 51: ...ghten 2 cables accessory Cable tie small Damper cables Transformer Power supply cable for dampers accessory Cable tie small PIN PIN 1 and 2 PIN 3 and 4 PIN 5 and 6 Descriptions OPEN COMMON CLOSE 4 Connecting with power supply earth ground wire Protective cable Power supply Cable clamp 47 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 52: ...optional remote sensor Remote sensor cables Indoor unit accessory Cable tie small CN8 black CN7 white sensor Remote accessory Cable tie small accessory Cable tie small sensor Remote 48 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 53: ...ory Cable tie small accessory Cable tie small Indoor unit Zone control interface connecting cable CN6 2 Connecting with wireless LAN adapter Cable tie accessory Wireless cable LAN adapter small Red White Black Functional earth ground wire 49 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 54: ... for dampers accessory Cable tie small Tighten 2 cables with a Cable tie small Damper cables OPEN COMMON CLOSE 4 Connecting with power supply Power supply cable Cable clamp Protective earth ground wire 50 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 55: ...sor accessory Cable tie small accessory Cable tie small accessory Cable tie small Indoor unit Zone control interface connecting cable CN7 white CN8 black Remote sensor Remote sensor Remote sensor cable 51 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 56: ...nnected to the same wireless router that the WLAN adapter is connected 1 Launch FGLair on your smart device 2 Follow the instructions written in the setting manual attached with this product 7 3 Zone control Prerequisites Make sure that the smart device is connected to the same wireless router that the WLAN adapter is connected Before setting the zone control make sure to complete the air conditio...

Страница 57: ...s LAN label Attached to the indoor unit beside the wireless LAN indicator 1 Tapping screw large M4 25 mm 2 8 2 Zone control interface Part name Exterior Q ty Part name Exterior Q ty Installation manual 1 Tapping screw M4 12 mm 3 Connecting cable 1 Cable tie small 9 One touch bush 3 Cable tie large 1 53 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Страница 58: ... 1 Zone control interface Exterior Part name Model name Summary Remote sensor unit UTY XSZX New amenity space can be offered by installing Remote sensor unit in the remote controller 54 ZONE CTRL SYSTEM with WLAN ADAPTER ...

Отзывы: