Event Notification
When an error occurs in the ETERNUS DX, the event notification function notifies the event information to the
administrator. The administrator can be informed that an error occurred without monitoring the screen all the
time.
The methods to notify an event are e-mail, SNMP Trap, syslog, remote support, and host sense.
Figure 46 Event Notification
SNMP
manager
Mail
server
Syslog server
Remote
support
center
REMCS/AIS Connect
Host sense
Server (host)
Syslog
SNMP Trap
ETERNUS DX
The notification methods and levels can be set as required.
The following events are notified.
Table 28 Levels and Contents of Events That Are Notified
Level
Level of importance
Event contents
Error
Maintenance is necessary
Component failure, temperature error, end of
battery life, rebuild/copyback, etc.
Warning
Preventive maintenance is neces-
sary
Module warning, battery life warning, etc.
Notification (information)
Device information
Component restoration notification, user log-
in/logout, RAID creation/deletion, storage
system power on/off, firmware update, etc.
●
When an event occurs, an e-mail is sent to the specified e-mail address.
The ETERNUS DX supports "SMTP AUTH" and "SMTP over SSL" as user authentication. A method can be selected
from CRAM-MD5, PLAIN, LOGIN, or AUTO which automatically selects one of these methods.
2. Basic Functions
Operation Management/Device Monitoring
84
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
P3AM-7722-25ENZ0
Содержание ETERNUS DX500 S3/DX600 S3
Страница 218: ......