10.9 System
The
DNS Suffix Search List
and
DNS IP Addresses
cannot be modified if the
ETERNUS CS800 is currently joined to a Windows domain. To disjoin a Windows
domain, see
"Disjoining a Workgroup or Domain" on page 210
.
Configuring Bonding Details
Under
IP Address Configuration > Bonding Details
, configure bonded devices (see
"Network Page: Bonding Details" on page 324
):
Figure 208: Network Page: Bonding Details
1. If necessary, click the
Show
link to show the bonding details table.
2. For each available bonded device (
bond0
,
bond1
, and so on), select two or more
Ethernet ports with the same link speed to assign to the bond. Or select
Not Bonded
to
leave a port unassigned to any bond.
If no ports are assigned to a bond, the bond cannot be configured. That is, settings
cannot be entered for the bond in the
Interface Details
or
IP Address
tables because no
Ethernet ports are assigned to the device.
All ports assigned to the same device are bonded together into a single logical port. For
example, if you select
bond0
for port
eth0
and port
eth1
, both ports are bonded together
in the
bond0
device. A bonded device can contain two or more ports.
All ports associated with a bond must have the same link speed (1GbE or 10GbE).
3. For each bonded device, specify the bonding mode:
To maintain network connectivity, the switch connected to the ETERNUS
CS800 must be configured to use the same bonding mode. The best time to
change the bonding mode on the switch is during the next reboot of your
system, after saving the new network settings. Changing the bonding mode
on the switch before saving these settings and rebooting may result in the
loss of network connectivity to the system.
324
ETERNUS CS800
Содержание ETERNUS CS800
Страница 1: ...ETERNUS CS800 V3 2 User Guide English ...
Страница 2: ......
Страница 3: ...English ETERNUS CS800 User Guide V3 2 Edition October 2015 ...
Страница 26: ...26 ...
Страница 42: ...42 ...
Страница 78: ...78 ...
Страница 114: ...6 3 Running the Getting Started Wizard 6 3 3 Network Configuration Figure 80 Network Configuration 114 ETERNUS CS800 ...
Страница 132: ...6 3 Running the Getting Started Wizard Figure 91 Confirm Page 132 ETERNUS CS800 ...
Страница 143: ...Figure 97 Remote Management Pages Map ETERNUS CS800 143 7 Remote Management ...
Страница 144: ...144 ...
Страница 184: ...8 7 AIS Connect Figure 128 AISConnect Wizard Confirm 184 ETERNUS CS800 ...
Страница 198: ...198 ...
Страница 321: ...Figure 206 Network Configuration ETERNUS CS800 321 10 Configuration ...
Страница 335: ...Figure 215 Date Time Page To set the system date and time ETERNUS CS800 335 10 Configuration ...
Страница 339: ...Figure 216 Access Control Settings Page ETERNUS CS800 339 10 Configuration ...
Страница 362: ...362 ...
Страница 432: ...432 ...
Страница 476: ...476 ...
Страница 494: ...494 ...
Страница 600: ...600 ...