1. ETERNUS AX/HX Installation
Installation Specifications
Site Planning Guide
16
ETERNUS HX6100
Each installation specification is shown below.
•
Installation specifications:
•
Sound level of the drive shelf:
•
Efficiency and the power factor of the power supply unit:
Table 10 Installation Specifications (ETERNUS HX6100)
Item
ETERNUS HX6100
Dimensions
(W
×
D
×
H)
Controller shelf
483
×
828
×
175 mm (4U)
DS212C 3.5" type drive shelf
480
×
505
×
87 mm (2U)
DS224C 2.5" type drive shelf
480
×
484
×
85 mm (2U)
DS460C 60-drive type drive shelf
486
×
922
×
176 mm (4U)
Power distribution unit (2U) (*1)
(485
×
123
×
44 mm)
×
2
Maximum weight (*2)
(*3)
3.5" type controller shelf
49.2 kg (53.2 kg)
DS212C 3.5" type drive shelf
28.7 kg (32.7 kg)
DS224C 2.5" type drive shelf
24.4 kg (28.4 kg)
DS226C 2.5" type drive shelf
22.2 kg (26.2 kg)
DS460C 60-drive type drive shelf
112 kg (116 kg)
Power distribution unit (2U) (*1)
(3.0 kg)
×
2
Power
Voltage
AC 100 – 120V, AC 200 – 240V
Phase
Single
Frequency
50 Hz / 60 Hz
Maximum power
consumption (*2)
Controller shelf
AC100 – 120V
1,512 W (1,543 VA)
AC200 – 240V
1,470 W (1,500 VA)
Drive shelf
DS212C
3.5" type
AC100 – 120V
338 W (345 VA)
AC200 – 240V
332 W (340 VA)
DS224C
2.5" type
AC100 – 120V
396 W (405 VA)
AC200 – 240V
389 W (398 VA)
DS460C 60-
drive type
AC100 – 120V
-
AC200 – 240V
1,541 W (1,558 VA)
Maximum configuration
(*4)
AC100 – 120V
25,272 W (22,243 VA)
AC200 – 240V
24,810 W (21,900 VA)
Maximum heat
generation (*2)
Controller shelf
AC100 – 120V
5,443 kJ/h
AC200 – 240V
5,292 kJ/h
Drive shelf
DS212C
3.5" type
AC100 – 120V
1,217 kJ/h
AC200 – 240V
1,195 kJ/h
DS224C
2.5" type
AC100 – 120V
1,426 kJ/h
AC200 – 240V
1,400 kJ/h
DS460C 60-
drive type
AC100 – 120V
-
AC200 – 240V
5,548 kJ/h
Maximum configuration
(*4)
AC100 – 120V
90,979 kJ/h
AC200 – 240V
89,316 kJ/h
Maximum amount of
exhaust air
Controller shelf
-
Drive shelf
2.5" type / 3.5" type
-
60-drive type
-
Содержание ETERNUS AX Series