D3031 (RX200 S6)
Technical Manual
31
Features
Connectors and indicators
LEDs A, B and C are visible from outside on the rear of the server. All the other
LEDs are only visible, if the cover of the server has been opened.
If the server has been powered off (power-plugs must be disconnected) it is
possible to indicate the faulty component by pressing the CSS indicate button.
The LEDs have the following meaning:
No.
Description
1
CSS indicate button
LED Indicator
Meaning
A - GEL
(Global Error
LED)
orange on
indicates a prefailure
orange flashing indicates a failure. Reasons for a failure
may be:
– a sensor detects an error
– sensor defect
– fan defect
– CPU e
rror
– Software detected an error
B - CSS
(Customer Self
Service)
yellow on
indicates a prefailure
yellow flashing indicates a failure
C - Identification blue on
server is identified via the ServerView
Operations Manager
D - Controller
orange on
controller failure
E - CPU
orange on
CPU failure
F - system fans green on
fan okay
orange on
fan failure
G - memory
orange on
memory module failure
H - iRMC S2
green flashing iRMC S2 okay