32
Technical Manual
D2799 (TX200 S6)
Connectors and indicators
The LEDs have the following meaning:
LED Indicator
Meaning
A - GEL
(Global Error
LED)
Off
No error (non CSS component)
Orange on
Indicates a prefailure (non CSS
component)
Orange
flashing
Indicates a failure. Reasons for a failure
may be:
–
a sensor detects an error
–
sensor defect
–
fan defect
–
CPU error
–
Software detected an error
B - CSS
(Customer Self
Service)
Off
No error (CSS component)
Yellow on
Indicates a prefailure (CSS component)
Yellow flashing
Indicates a failure (CSS component)
C - Identification Blue on
Server is identified via the ServerView
Operations Manager
Blue flashing
Local monitor off via AVR
D1 - board
Yellow on
AUX voltage available
D2 - board
Green on
System running
D3 - board
Red on
Configuration error.
The system board will be held in reset.
Possible configuration errors are e.g.: old
CPU populated, CPUs with different FSB
requirements populated, CPU1 not
populated.
D4 - board
Green flashing
iRMC S2 ok
On / off
iRMC S2 inactive
E1 - overall
memory
Off
All memory modules running
Orange on
At least one memory module defective
E2 - memory
Off
Memory module running
Orange on
Memory module failure
F - system
fans
Off
Fan running
Orange on
Fan failure
Содержание D2799
Страница 1: ...Technical Manual English System Board D2799 for PRIMERGY TX200 S6 Technical Manual Edition July 2010 ...
Страница 6: ...Technical Manual D2799 TX200 S6 ...
Страница 8: ...Technical Manual D2799 TX200 S6 Contents ...
Страница 10: ...10 Technical Manual D2799 TX200 S6 Notational conventions ...
Страница 36: ...36 Technical Manual D2799 TX200 S6 Settings ...
Страница 38: ...38 Technical Manual D2799 TX200 S6 Replacing the lithium battery ...