30
Technical Manual
D2786
(RX200
S5)
Connectors and indicators
Features
Clear CMOS - jumper JP2
Proceed as follows to delete the CMOS settings:
Ê
Create a backup of all the data.
Ê
Shut down the server.
Ê
Remove all power and connection cables.
Ê
Remove the housing cover.
Ê
If necessary, remove the expansion card which hinders access to jumper
JP2 (Clear CMOS).
Ê
Remove jumper JP2 from position 1-2 and insert it in position 2-3 for 20 to
30 seconds.
Ê
Insert jumper JP2 in position 1-2 again.
Ê
Reinsert the expansion card.
Ê
Close the server’s housing cover.
Ê
Connect all the power and connection cables again.
Ê
Switch the server on again.
Ê
During the POST process press
[F2]
in order to enter the Setup Utility.
Ê
Press
[F9]
to set the system defaults.
Ê
Press
[F10]
to save your changes and to exit the Setup Utility.
Jumper
Pos. Description
1-2
Normal, not clear CMOS settings (default setting).
2-3
Clear CMOS settings and restore default values
(hardware).