System Board D2786
for RX200 S5 

Technical Manual

Edition April 2009

Содержание D2786

Страница 1: ...System Board D2786 for RX200 S5 Technical Manual Edition April 2009 ...

Страница 2: ...consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2009 FujitsuTechnologySolutionsGmbH All rights reserved Delivery subject to avai...

Страница 3: ...mity 10 2 3 Environmental protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 17 3 3 PCI slots 20 3 4 Screen resolution 21 3 5 Temperature system monitoring 22 3 6 Connectors and indicators 23 3 6 1 System board 23 3 6 2 Connector panel 27 3 6 3 Jumpers and switches 29 4 Replacing the lithium battery 33 Abbreviations 35 ...

Страница 4: ......

Страница 5: ...icates system output on the monitor Text in semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbol...

Страница 6: ......

Страница 7: ...re to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging or in pac...

Страница 8: ...minimum requirement the use of a protected LAN line of category 5 for 10 100 Mbit s Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm risk of lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of ex...

Страница 9: ...ching the components The equipment and tools you use must be free of static charges Shut down the system and remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you...

Страница 10: ...on boards are slotted in straight without damaging components or conductors on the board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screw drivers for leverage 2 2 CE certificate of conformity The board c...

Страница 11: ...n of work Packaging information Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumables Please dispose of batteries in accordance with local regulations In accordance with EU directives batteries must not be disposed of with unsorted domestic waste They can b...

Страница 12: ...itsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 333 18010 The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EG on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used equipment and is valid across the EU When returning...

Страница 13: ...stered DIMM memory modules capacity UDIMMs 1 GB or 2 GB capacity RDIMMs 2 GB 4 GB or 8 GB minimum memory configuration one DIMM with independent channel mode maximum 96 GB with RDIMMs or 24 GB with UDIMMs of memory ECC multiple bit error detection and single bit error correction memory scrubbing function Single Device Data Correction SDDC function Chipkill only with RDIMMs memory mirroring functio...

Страница 14: ...disk drives 1x SATA connector optical disk drive 1x connector for UFM 1x main power connector 1x power supply monitoring and controlling connector 6x system fan monitoring and controlling connectors 1x connector for the front side video port 1x front panel connector 1x connector for TPM External connectors Rear side 1x serial interface COM 3x USB connectors 1x VGA connector 2x RJ45 LAN connectors ...

Страница 15: ...rnal serial port LAN PCI Express controller and iRMC S2 power on by power button external serial port LAN PCI Express controller and iRMC S2 BIOS features Phoenix SecureCoreTM Server BIOS version 6 0 SMBIOS 2 50 DMI MultiProcessor Specification 1 4 Server Hardware Design Guide 3 0 WfM 2 0 IPMI V2 0 ACPI 2 0 support USB keyboard mouse boot possible from CD ROM USB drive LAN PXE and iSCSI console re...

Страница 16: ...y an add on kit This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the BIOS manual V CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a backup of the TPM content ...

Страница 17: ...r installing UDIMM memory modules 24 GB for installing RDIMM memory modules 96 GB Mixing both types of memory modules is forbidden ECC with memory scrubbing and with the Single Device Data Correction SDDC function only with RDIMMs is supported I You will find the descriptions how to install memory modules in the Options Guide of your server Figure 2 Slots of the main memory CPU 2 CPU 1 DIMM 1C DIM...

Страница 18: ...Mode Allows population of all channels in any order Related to the channels A F DIMM1 must be populated first Works with DIMMs of different clock rates and applies the lowest clock rate Works with UDIMMs as well as RDIMMs CPU 1 CPU 2 CPU 2 CPU 2 CPU 2 CPU 1 CPU 1 CPU 1 DIMM 1C DIMM 1B DIMM 1A DIMM 2B DIMM 2A DIMM 2C DIMM 2D DIMM 2E DIMM 2F DIMM 1E DIMM 1F DIMM 1D Independent Channel Mode DIMM 1C D...

Страница 19: ...for the applications Channel C CPU 1 respectively channel F CPU 2 are not available in this mode RDIMMs are supported Performance Channel Mode Requires identical modules on all channels of each bank per CPU RDIMMs are supported Spare Channel Mode Requires identical modules on all channels of each bank per CPU One third of the capacity is used as spare range this means the main memory for the appli...

Страница 20: ...lot Description 1 PCI Express x8 standard profile half length 2 PCI Express x8 low profile half length 3 PCI Express x4 mechanically x8 low profile half length S1 Front VGA Slot 2 Slot 1 UFM SATA1 Slot 3 PWR CTRL CPU 1 JP5 Battery DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A JP2 iRMC 2 3 1 ...

Страница 21: ...ne low profile half length PCI Express expansion x4 slot mechanically x8 reserved for modular RAID option 3 4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the screen controller on the system board If you are using an external screen controller you will find details of supported screen resolutions in the operating manual or technica...

Страница 22: ...y module temperature by a temperature sensor on the depending memory module Fan monitoring Fans that are no longer available blocked or sticky fans are detected Fan control The fans are controlled according to the temperature Sensor monitoring The removal of or a fault in a temperature sensor is detected Should this happen all fans monitored by this sensor run at maximum speed to achieve the great...

Страница 23: ...ernal connectors of the system board D2786 S1 TPM Front VGA Slot 2 Slot 1 UFM SATA1 Slot3 PWR CTRL PWR Front Panel Indicate CSS button CPU 2 CPU 1 SATA ODD JP5 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 1 2 Fan 3 4 Fan 5 6 Fan 7 8 Fan 9 10 Fan 11 12 JP2 iRMC 1 2 3 4 5 6 7 8 9 ...

Страница 24: ... Connector for the front side video port 2 CN10 Connector for USB Flash Module 3 CN1 PSU I2C connector 4 CN11 SATA1 HDD connector 4 ports 5 CN13 PSU main connector 6 SATA2 SATA ODD connector 7 CN2 Connector for front panel 8 JP4 JP6 JP7 JP10 JP11 JP12 System fan connectors 9 CN30 Connector for TPM ...

Страница 25: ... board and indicate CSS button S1 TPM Front VGA Slot 2 Slot 1 UFM SATA1 Slot3 PWR CTRL PWR Front Panel Indicate CSS button CPU 2 CPU 1 SATA ODD JP5 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 1 2 Fan 3 4 Fan 5 6 Fan 7 8 Fan 9 10 Fan 11 12 JP2 iRMC 1 ...

Страница 26: ...onger than 24 hours No Description 1 Indicate CSS button LED Indicator Meaning A GEL Global Error LED orange indicates a prefailure orange flashing indicates a failure Reasons for a failure may be a sensor detects an error sensor defect fan defect CPU error Software detected an error B CSS Customer Self Service yellow indicates a prefailure yellow flashing indicates a failure C Identification blue...

Страница 27: ...hard disk drive PXE is supported here The separate service LAN connector is used as a management interface iRMC S2 and is prepared for operation with the Remote Management Optionally LAN connector 1 can also be used for iRMC S2 server management Each LAN connector has two LEDs which display the speed of the connection and its status No Description 1 USB connectors 2 Global error indicator orange C...

Страница 28: ...dy green signal in the event of a LAN transfer rate of100 Mbps Remains dark in the event of a LAN transfer rate of 10 Mbps 3 LAN activity standard LAN Steady green signal when a LAN connection exists Remains dark when no LAN connection exists Flashes green when LAN transfer takes place 4 LAN transfer rate standard LAN Flashes yellow in the event of a LAN transfer rate of 1 Gbps Steady green signal...

Страница 29: ...s and indicators 3 6 3 Jumpers and switches Figure 9 Jumpers and switches I The default setting for all jumpers is position 1 2 S1 Front VGA Slot 2 Slot 1 UFM SATA1 Slot 3 PWR CTRL CPU 1 JP5 Battery DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A JP2 iRMC ...

Страница 30: ... JP2 from position 1 2 and insert it in position 2 3 for 20 to 30 seconds Ê Insert jumper JP2 in position 1 2 again Ê Reinsert the expansion card Ê Close the server s housing cover Ê Connect all the power and connection cables again Ê Switch the server on again Ê During the POST process press F2 in order to enter the Setup Utility Ê Press F9 to set the system defaults Ê Press F10 to save your chan...

Страница 31: ...l operation default setting 2 3 Clear ME_RTC REG Switches Function Status Description S1 1 BIOS recovery On Boot block enabled Off Normal boot S1 2 Skip BIOS password query On Password disabled Off Password enabled S1 3 BIOS write protect On BIOS can only be read Off BIOS can both be read and written to S1 4 CMOS clear software On Clear CMOS settings and restore system defaults Off Normal CMOS set...

Страница 32: ......

Страница 33: ...placed with an identical battery or a battery type recommended by the manufacturer CR2032 Do not throw lithium batteries into the trash can It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 10 Replacing the lithium battery Ê Press the locking spring into direction of...

Страница 34: ......

Страница 35: ...ons listed here are valid for the described system board ACPI Advanced Configuration and Power Interface ASR R Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CRU Customer Replaceable Unit CSS Customer Self Service C...

Страница 36: ...anagement Interface DMA Direct Memory Access DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic ESD Electrostatic Discharge EVRD Enterprise Voltage Regulator Down FBD Fully Buffered DIMM HDD Hard Disk Drive ...

Страница 37: ...ated Mirror Enhanced IOOP Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller LAN Local Area Network LED Light Emitting Diode MCH Memory Controller Hub MPS Multi Processor Specification NMI Non Maskable Interrupt NOS Network Operating System ...

Страница 38: ... Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device POST Power On Self Test PS U Power Supply Unit PWM Pulse Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks ...

Страница 39: ... Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SHPC Standard Hot Plug Controller SMB System Management Bus SMM Server Management Mode SMP Symmetrically Multi Processing ...

Страница 40: ...tions TPM Trusted Platform Module UFM USB Flash Module UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN ...