Fujitsu D2239 Скачать руководство пользователя страница 5

D2239 (TX150 S4)

Technical Manual

5

1

Introduction

This technical manual describes the system board D2239, which can be 
equipped with one Intel

®

 processor.

You will find further information in the manual “BIOS Setup”.

Further information about drivers is provided in the readme files on the hard 
disk, on the supplied “ServerSupport” or “ServerStart” CDs.

Notational conventions

The meanings of the symbols and fonts used in this manual are as follows:

italics

indicates commands, menu items, file and path 
names or software programs

fixed font

indicate system output on the monitor

semi-bold fixed font

indicates values to be entered through the 
keyboard

[Key symbol]

indicates keys according to their representation on 
the keyboard

If capital letters are to be entered explicitly, then the 
Shift key is shown, e.g. 

[SHIFT]

 - 

[A]

 for A.

If two keys need to be pressed at the same time, 
then this is shown by placing a hyphen between the 
two key symbols.

“quotation marks”

indicates names and terms that are being empha-
sized.

Ê

indicates an operation that to be performed

V

CAUTION!

indicates warnings, which, if ignored, will endanger 
your health, destroy the system or lead to the loss 
of data.

I

indicates additional information, notes and tips

Table 1: Notational conventions

Содержание D2239

Страница 1: ...for TX150 S4 Technical Manual Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e mail email manuals fujitsu siemens com Tel 089 61001 155 Fax 49 700 372 00000 D2239 TX150 S4 Sprachen En Edition February 2006 ...

Страница 2: ...according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers Gmb...

Страница 3: ...ificate 10 2 3 Environmental Protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 16 3 3 PCI bus 17 3 4 Screen resolution 20 3 5 Temperature system monitoring 20 3 6 Interfaces and connectors 22 3 6 1 Settings with jumpers 24 3 6 2 External connectors 24 4 Replacing the lithium battery 27 Abbreviations 29 ...

Страница 4: ......

Страница 5: ...ixed font indicate system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key sy...

Страница 6: ......

Страница 7: ...f Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packagin...

Страница 8: ...s minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosion ...

Страница 9: ...ouching a grounded object before working The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you inst...

Страница 10: ...at care when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use...

Страница 11: ...and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the househol...

Страница 12: ... 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable throughou...

Страница 13: ...133 200 MHz front side bus Main Memory 4 slots for main memory DDR2 533 667 MHz unbuffered SDRAM memory modules with 512 MB up to 8 Gbyte maximum 8 Gbyte of memory minimum 512 MB ECC multiple bit error detection and single bit error correction Chips on the system board Intel iE7230 chipset ATI VGA controller RAGE XL Intel i82801 ICH7R chipset Intel PXH V PCI X bridge Super I O controller SMSC DME1...

Страница 14: ...tion RSB power IPMB HDD LED front panel battery holder dual USB 2 0 USB3 4 buzzer SMB1 external connectors 2 serial ports COM1 COM2 1 parallel port 2 PS 2 interfaces for keyboard and mouse 2 USB 2 0 ports with 480 Mbits s rear 1 USB 2 0 port with 480 Mbits s front panel 1 VGA port 1 RJ45 LAN port PCI slots 2 x PCI X 64 Bit 66 MHz slot 2 prepared for ZCR ZCR only possible in SCSI version 3 x PCI 32...

Страница 15: ...1 0 support LSI IME SCSI BIOS USB keyboard mouse boot possible from 120 MB floppy disk drive CD ROM USB drives LAN console redirection support OEM logo optional Memory disable no Alert on LAN Environmental protection Battery in holder Form factor slot compatibility list ATX L ACPI 1 0b OnNow PCI 2 3 PCI X1 0b PCI X2 0 PCI Express 1 0a WfM 2 0 SHDG 3 0 MPS 1 4 IPMI 1 5 PCI SHPC 1 0 USB2 0 ...

Страница 16: ... pair must consist of identical memory modules 2 way interleaved mode The module capacity between pairs can differ pair 2A 2B can be populated with two 512 Mbyte memory modules and pair 1A 1B with two 1 Gbyte memory modules Following table shows the mandatory population order DIMM_1A DIMM_2A DIMM_1B DIMM_2B single channel populated empty empty empty empty populated empty empty empty empty populate...

Страница 17: ...for Zero Channel RAID ZCR ZCR means that the oboard SCSI controller can be upgraded to a SCSI RAID controller through the inserted ZCR PCI card PCI slot 64Bit 32Bit Frequency MHz Description 1 32 Bit 33 32 bit PCI bus slot 2 64 Bit 66 64 bit PCI X bus slot prepared for ZCR 3 64 Bit 66 64 bit PCI X bus slot 4 32 Bit 33 32 bit PCI bus slot 5 32 Bit 33 32 bit PCI bus slot 6 PCIe x4 bus slot 7 PCIe x1...

Страница 18: ...lot The PCI interrupts INTA INTB INTC and INTD are available for each PCI slot The same interrupt can be assigned simultaneously to several PCI boards You should avoid this condition due to reduced performance If you use a setting other than Auto the Plug Play functionality of the system BIOS for the corresponding PCI boards is deactivated Auto The PCI interrupts are assigned automatically in acco...

Страница 19: ... Slot USB 1 1 U S B 2 0 S M B u s S C S I P X H V L A N P CI e I C H 1 2 3 4 5 6 7 1st 2nd 3rd 4th PCI PCI X PCI X PCI PCI PCIe x4 PCIe x1 ICH PXH V ZCR PXH V ICH ICH ICH ICH 1 A x B D B D 2 B x C A C A 3 C D D B C A D B 4 D x C A C D B A 5 E x 6 F x B A C 7 G x A B D 8 H x x P X H V 0 B D 1 C A 2 D B 3 A C IDSel 21 19 25 23 25 ...

Страница 20: ...emperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by an onboard controller The following functions are supported Temperature monitoring Measurement of ...

Страница 21: ...ection of the hardware Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated Cover monitoring Unauthorized opening of the cover is detected even when the system is switched off However this will only be indicated when the system is switched on again System Event Log SEL All monitored events of the system board are recorded in the Sys...

Страница 22: ...e system board D2239 SCSI version 1 CPU fan 11 Intrusion detection 2 Floppy disk drive 12 SMB1 I C temperature sensor 3 Front panel 13 RSB LP power 4 PC98 14 IPMB 5 IDE 15 HDD activity 6 Power supply 16 Buzzer 7 PSU 12V connector CPU 17 System fan 1 8 USB 3 4 18 external ports 9 System fan 2 19 PWD SKIP RCVR jumper 10 SCSI U320 ...

Страница 23: ...SATA version 1 CPU fan 10b SATA LED 2 Floppy disk drive 11 Intrusion detection 3 Front panel 12 SMB1 I C temperature sensor 4 PC98 13 RSB LP power 5 IDE 14 IPMB 6 Power supply 15 HDD activity 7 PSU 12V connector CPU 16 Buzzer 8 USB 3 4 17 System fan 1 9 System fan 2 18 external ports 10a SATA 1 4 19 PWD SKIP RCVR jumper ...

Страница 24: ...xternal connectors Figure 7 External ports of the system board D2239 default System BIOS recovery disabled Password skip disabled PWD SKIP Skip password enabled RCVR Recover system BIOS enabled 1 PS 2 mouse port 6 Serial port COM2 2 Parallel port 7 Serial port COM1 3 LAN port 8 PS 2 keyboard port 4 VGA port 9 ID LED 5 USB port 1 2 10 Global Error LED 1 3 4 5 2 6 7 8 9 10 ...

Страница 25: ...ce without its own boot hard disk via LAN Here Intel PXE is supported The LAN port serves as management interface and is prepared for RemoteView The LAN controller connectors are equipped with two LEDs light emitting diode indicating the transfer rate and the activity LED Indicator Meaning 9 Identify blue Server is identified via ServerView 10 Global Error orange Indicates a prefailure orange flas...

Страница 26: ...res Figure 8 LAN connectors 1 LAN link activity green ON LAN connection OFF no LAN connection flashing LAN transfer 2 LAN transfer rate green yellow OFF transfer rate 10 Mbit s or no connection green ON transfer rate 100 Mbit s yellow ON transfer rate 1000 Mbit s 1 2 ...

Страница 27: ...replaced with an identical battery or a battery type recommended by the manufacturer CR2032 Do not throw lithium batteries into the trashcan It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 9 Replacing the lithium battery Ê Press the locking spring into direction of...

Страница 28: ......

Страница 29: ... listed here are valid for the described system board ACPI Advanced Configuration and Power management Interface ASRR Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CPU Central Processing Unit DDR Double Data Rate D...

Страница 30: ...ion Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD HPC Hot plug Controller ICE In Circuit Emulation IDE Integrated intelligent Drive Electronics IME Integrated Mirror Enhanced IOOP Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus ...

Страница 31: ...iode MPS Multi Processor Specification NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device PS U Power Supply Unit PWM Puls Wide Modulation ...

Страница 32: ...ST ReSeT RTC Real Time Clock SATA Serial Advanced Technology Attachment SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SMB System Management Bus SMM Server Management Mode SMP Symmetrically Multi Processing UHCI Unified Host Controller Interface ...

Страница 33: ...D2239 TX150 S4 Technical Manual 33 Abbreviations USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN ...

Страница 34: ......

Страница 35: ...for TX150 S4 D2239 TX150 S4 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 München Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Страница 36: ......

Страница 37: ...for TX150 S4 D2239 TX150 S4 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 München Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Страница 38: ......

Страница 39: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Отзывы: