background image

Interfaces and connectors

8 - English

A26361-D1483-Z120-1-7619

UBS Port A/B - Dual Channel

(internal or external via special wire)

1

2

Pin

Signal

Pin

Signal

1

VCC Dual (max. 250 mA)

2

VCC Dual (max. 250 mA)

3

Reserved

4

Key

5

Power supply on

(max. 1 second low pulse)

6

GND

7

Data positive

8

Data negative

9

GND

10

Over current (low asserted)

Power Connector

2

1

Pin

Signal

1

GND

2

GND

3

+12 V

4

+12 V

Power Supply ATX Connector
(Internal)

1

11

Pin

Signal

Pin

Signal

1

+3.3 V

11

+3.3 V

2

+3.3 V

12

-12 V

3

GND

13

GND

4

+5 V

14

PS on (low asserted)

5

GND

15

GND

6

+5  V

16

GND

7

GND

17

GND

8

Powergood (high asserted)

18

-5 V

9

+5 V Auxiliary

19

+5 V

10

+12 V

20

+5 V

Содержание D1483

Страница 1: ...Technical Manual Mainboard D1483 English answers2 ...

Страница 2: ...ed Please contact your sales partner your sales outlet You will find further information in the manuals Safety and Ergonomics The latest information and updates e g BIOS update on our mainboards can be found on the Internet under http www fujitsu siemens com mainboards ...

Страница 3: ......

Страница 4: ...manual ha sido impreso sobre papel reciclado Questo manuale è stato stampato su carta da riciclaggio Denna handbok är tryckt på recyclingpapper Dit handboek werd op recycling papier gedrukt Published by Fujitsu Siemens Computers GmbH Order No A26361 D1483 Z120 1 7619 Printed in the Federal Republic of Germany AG 1102 11 02 A26361 D1483 Z120 1 7619 ...

Страница 5: ...Mainboard D1483 Technical Manual English November 2002 edition ...

Страница 6: ...marks of their respective owners whose protected rights are acknowledged All rights including rights of translation reproduction by printing copying or similar methods even of parts are reserved Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Delivery subject to availability Right of technical modifi...

Страница 7: ... RSB Power Connector CN5 7 IPMI Connector CN6 7 UBS Port A B Dual Channel 8 Power Connector 8 Power Supply ATX Connector Internal 8 Floppy Connector 9 Intelligent Drive Electronics IDE Interface Internal 10 Temperature System Monitoring 11 LAN Connector A 10 100 Mbit 11 LAN Connector B 1 GbE 12 PCI Bus Resources 13 PCI Slots 13 PCI IRQ Line X Assignment of the PCI Interrupts 13 Screen Resolution 1...

Страница 8: ......

Страница 9: ...more details please read the according readme txt files Notational Conventions The meanings of the symbols and fonts used in this manual are as follows Pay particular attention to text marked with this symbol Failure to observe this warning endangers your life destroys the device or may lead to loss of data i Supplementary information remarks and tips follow this symbol Ê Text which follows this s...

Страница 10: ...ent of expansions Information on which expansions you can use is available from your sales outlet or the customer service centre Information about Boards To prevent damage to the mainboard the components and conductors on it please take great care when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on th...

Страница 11: ...NS87414 floppy disk drive controller possible formats 720 Kbyte 1 44 Mbyte and 2 88 Mbyte Northbridge Server Works GC SL Southbridge Server Works CSB6 VRM 9 1 ATI Rage XL 4 Mbyte EEPROM SST 4 Mbyte IPMI server management onboard System Monitoring Security Functions Simple error detection and correction in the main memory with an ECC only for memory modules with ECC System setup and keyboard passwo...

Страница 12: ...4 15 2 1 4 5 6 7 8 9 3 1 RSB power connector 2 IPMI connector 3 Sys fan connector 1 4 Sys fan connector 2 5 FDD connector 6 CN9 internal USB port 7 CN8 connector for LED board USB 8 ATX power supply 9 RAID secondary connector 10 Power supply 12 V 11 CPU fan connector 2 12 RAID primary connector 13 CPU fan connector 1 14 IDE connector for CD ROM DVD drives 15 4 pin power connector JP4 ...

Страница 13: ...D1483 Z120 1 7619 English 5 External Connectors 1 3 4 5 6 7 2 1 USB port black 2 PS 2 mouse port green 3 PS 2 keyboard port purple 4 VGA port blue 5 LAN connector A 10 100 Mbit 6 LAN connector B 1 GbE 7 Serial interface COM1 turquoise ...

Страница 14: ...llowing connectors are optional LAN Connector A 10 100 82550 Ethernet Port External 1 Pin Signal 1 TX 2 TX 3 RX 4 TERMPLANE 5 TERMPLANE 6 RX 7 TERMPLANE 8 TERMPLANE LAN Connector B 1 GbE 82540 Ethernet Port External 1 Pin Signal 1 TX 2 TX 3 RX 4 TERMPLANE 5 TERMPLANE 6 RX 7 TERMPLANE 8 TERMPLANE ...

Страница 15: ...ervised 1 Pin Signal 1 GND 2 Controlled fan voltage 0 V 6 V 12 V or Fix fan voltage 12 V 3 Sense PSU Fan Connector CN15 1 Pin Signal 1 GND 2 Controlled fan voltage 0 V 6 V 12 V or Fix fan voltage 12 V RSB Power Connector CN5 1 Pin Signal 1 GND 2 VCC5SBY IPMI Connector CN6 1 Pin Signal 1 IPMBDAT 2 GRD 3 IPMBCLK 4 Not connected ...

Страница 16: ...Power supply on max 1 second low pulse 6 GND 7 Data positive 8 Data negative 9 GND 10 Over current low asserted Power Connector 2 1 Pin Signal 1 GND 2 GND 3 12 V 4 12 V Power Supply ATX Connector Internal 1 11 Pin Signal Pin Signal 1 3 3 V 11 3 3 V 2 3 3 V 12 12 V 3 GND 13 GND 4 5 V 14 PS on low asserted 5 GND 15 GND 6 5 V 16 GND 7 GND 17 GND 8 Powergood high asserted 18 5 V 9 5 V Auxiliary 19 5 V...

Страница 17: ...or 1 Pin Signal Pin Signal 1 VCC5 FDD 14 STEP 2 INDEX 15 GND 3 VCC5 FDD 16 WDATA 4 DRV0 17 GND 5 VCC5 FDD 18 WGATE 6 DSKCHG 19 GND 7 Not Connected 20 TRKO 8 Not Connected 21 GND 9 Not Connected 22 WRTPRT 10 MTRO 23 GND 11 Not Connected 24 RDATA 12 DIR 25 GND 13 DENSEL 26 HDSEL ...

Страница 18: ... High Asserted 12 Data 12 High Asserted 13 Data 2 High Asserted 14 Data 13 High Asserted 15 Data 1 High Asserted 16 Data 14 High Asserted 17 Data 0 High Asserted 18 Data 15 High Asserted 19 GND 20 Key 21 DRQ High Asserted 22 GND 23 I O write Low Asserted 24 GND 25 I O read Low Asserted 26 GND 27 I O ready High Asserted 28 Cable select 29 DAK Low Asserted 30 GND 31 IRQ High Asserted 32 Not connecte...

Страница 19: ...system is switched on again the BIOS processes the application Fan Control The four fans are regulated according to temperature Sensor Monitoring The removal of or a faulty error within the system detection is done by a temperature sensor Should this happen all fans are monitored by this sensor and run at maximum speed to achieve the greatest possible protection of the hardware When the system is ...

Страница 20: ... The LAN controller is equipped with a 3 Kbyte transmission and receiving buffer FIFO and supports WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN Here Bootix LAN BootP and Intel PXE are supported The LAN RJ45 connector is equipped with a green and a bi color yellow green LED light emitting diode 1 2 3 Green indicator 4 Bi color yellow ...

Страница 21: ...I interrupts INTA INTB INTC and INTD are available for every PCI slot The same interrupt can be assigned simultaneously to several PCI boards You should avoid this condition due to reduced performance If you use a setting other than Auto the Plug Play functionality of the system BIOS for the corresponding PCI boards is deactivated Auto The PCI interrupts are assigned automatically in accordance wi...

Страница 22: ...ng an external screen controller you will find details of supported screen resolutions in the Operating Manual or Technical Manual supplied with the controller Screen resolution Refresh rate Hz Max number of colours 640x480 200 16 7 mio 800x600 200 16 7 mio 1024x768 150 16 7 mio 1057x864 120 16 7 mio 1280x1024 100 16 7 mio Horizontal values tolerance 0 3 kHz Shaded screen resolutions are not suppo...

Страница 23: ... block Clear CMOS Jumper JP1 1 2 Normal CMOS setting Default CMOS will not be cleared default entry 2 3 CMOS settings are not cleared Power On Circuit Jumper JP2 The system is powered on by one of the following mechanisms IPMI or South Bridge 1 2 Power on by IPMI Default 2 3 Power on by South Bridge Boot Block Jumper JP3 1 2 Normal Default 2 3 Boot Block ...

Страница 24: ...ps described in this chapter pull the power plug out of the mains outlet DIMM 2 DIMM 3 DIMM 1 2 1 3 4 5 1 Lithium battery 2 PCI slot 2 low profile 3 PCI slot 1 riser card for RSB 4 Memory sockets Slot Sequence No sequence concern for PCI slots Both PCI slots support 3 3 V operating voltage ...

Страница 25: ...You may only use unstacked modules LP DDR memory modules must be designed for a clock frequency of 133 MHz meets PC2100 specification Installing a Memory Module 2 2 Ê Push the holders on each side of the memory compartment outwards Ê Insert the memory module in the slot while folding the side holders up until the memory module engages 2 Removing a Memory Module 1 1 Ê Push the clips on the right an...

Страница 26: ...y be replaced only with an identical battery or with a type recommended by the manufacturer Do not throw lithium batteries into the household waste They must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top The lithium battery holder exists in different designs that function in th...

Страница 27: ...ea Network RAMDAC Random Access Memory Digital Analogue Converter CPU Central Processing Unit RDRAM Rambus Dynamic Random Access Memory CNR Communication Network Riser RIMM Rambus Inline Memory Module C RIMM Continuity Rambus Inline Memory Module RTC Real Time Clock DIMM Dual Inline Memory Module SB Soundblaster ECC Error Correcting Code SDRAM Synchronous Dynamic Random Access Memory EEPROM Electr...

Страница 28: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Отзывы: