background image

A26361-D1031-Z120-10-7419

English - 1

Introduction

i

This system board is available in different configuration levels. Depending on the
hardware configuration of your device, it may be that you cannot find several options in
your version of the system board, even though they are described.

You may find further information in the description "BIOS Setup".

Further information to drivers is provided in the readme files on hard disk or on the supplied drivers
diskettes or on the "Drivers & Utilities" or "ServerStart" CD.

Notational conventions

The meanings of the symbols and fonts used in this manual are as follows:

!

Pay particular attention to texts marked with this symbol. Failure to observe this
warning endangers your life, destroys the system, or may lead to loss of data.

i

Supplementary information, remarks and tips follow this symbol.

Ê 

Texts which follow this symbol describe activities that must be performed in the order shown.

Ë

This symbol means that you must enter a blank space at this point.

Ú

Ú

Ú

Ú

This symbol means that you must press the Enter key.

Texts in this typeface

are screen outputs.

Texts in this bold typeface

are the entries you make via the keyboard.

Texts in italics

indicate commands or menu items.

"Quotation marks" indicate names of chapters and terms that are being emphasized.

Important notes

Store this manual close to the device. If you pass on the device to third parties, you should also
pass on this manual.

!

Be sure to read this page carefully and note the information before you open the device.

You cannot access the components of the system board without first opening the device.
How to dismantle and reassemble the device is described in the Operating Manual
accompanying the device.

Please note the information provided in the chapter "Safety" in the Operating Manual of
the device.

Incorrect replacement of the lithium battery may lead to a risk of explosion. It is therefore
essential to observe the instructions in the chapter „

Add-on modules

“ - „

Replacing the

lithium battery

“.

Содержание D1031

Страница 1: ... S Y S T E M B A U G R U P P E D 1 0 3 1 S Y S T E M B O A R D D 1 0 3 1 S Y S T E M B O A R D D 1 0 3 1 S Y S T E M B O A R D D 1 0 3 1 S Y S T E M B O A R D D 1 0 3 1 TECHNISCHES HANDBUCH TECHNISCHES HANDBUCH TECHNISCHES HANDBUCH TECHNISCHES HANDBUCH TECHNICAL MANUAL TECHNICAL MANUAL TECHNICAL MANUAL TECHNICAL MANUAL ...

Страница 2: ... unseren Produkten Tipps Updates usw finden Sie im Internet http www fujitsu siemens com Is there any technical problem or other question you need clarified Please contact one of our service partners your sales partner your sales outlet The addresses of your service partners are contained in the guarantee booklet or in the service address booklet The latest information on our products tips updates...

Страница 3: ......

Страница 4: ...manuale è stato stampato su carta da riciclaggio Denna handbok är tryckt på recyclingpapper Dit handboek werd op recycling papier gedrukt Herausgegeben von Published by Fujitsu Siemens Computers GmbH Bestell Nr Order No A26361 D1031 Z120 1 7419 A26361 D1031 Z120 1 7419 A26361 D1031 Z120 1 7419 A26361 D1031 Z120 1 7419 Printed in the Federal Republic of Germany AG 0100 01 00 A26361 D1031 Z120 1 741...

Страница 5: ...Systembaugruppe D1031 System board D1031 Technisches Handbuch Technical Manual Deutsch English Ausgabe Januar 2000 January 2000 edition ...

Страница 6: ... vorbehalten insbesondere für den Fall der Patenterteilung oder GM Eintragung Liefermöglichkeiten und technische Änderungen vorbehalten Intel and Pentium are registered trademarks and MMX and OverDrive are trademarks of Intel Corporation USA Microsoft MS MS DOS and Windows are registered trademarks of Microsoft Corporation PS 2 and OS 2 Warp are registered trademarks of International Business Mach...

Страница 7: ...screen resolution 5 Interrupt table 5 SCSI bus termination 6 Settings on the system board 7 Recovering System BIOS switch 1 8 Write protection for System BIOS switch 3 8 Write protection for floppy disk drive switch 4 8 Clock speed switch 5 6 7 and 8 9 Add on modules 10 Upgrading main memory 11 Replacing the processor 11 Replacing the lithium battery 13 Glossary 14 ...

Страница 8: ......

Страница 9: ...erformed in the order shown Ë This symbol means that you must enter a blank space at this point Ú Ú Ú Ú This symbol means that you must press the Enter key Texts in this typeface are screen outputs Texts in this bold typeface are the entries you make via the keyboard Texts in italics indicate commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized Impo...

Страница 10: ...s To prevent damage to the system board or the components and conductors on it please take great care when you insert or remove boards Take care above all to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be especially careful with the locking mechanisms catches centering pin...

Страница 11: ... PCI bus graphics processor Cirrus Logic CL GD5446 2 Mbyte DRAM video memory Ultra 2 SCSI controller SYM 53C895 with SCSI bus extension SYM 53C141 IDE hard disk controller connected to PCI bus for two IDE drives System boot from SCSI CD ROM is possible Real time clock calendar with integrated battery backup Floppy disk controller up to 2 88 Mbytes format Connectors for two fans temperature sensor ...

Страница 12: ... 2 5 Temperature sensor for processor 1 6 Temperature sensor for processor 2 7 Control panel 8 Cover monitoring 9 Power supply voltage 10 Fan 1 11 Loudspeakers 12 Fan 2 13 USB port internal 14 SCSI indicator 15 Ultra SCSI SE 16 IDE drives 17 Ultra 2 SCSI LVD SE 18 Floppy disk drives 19 Wake On LAN WOL 20 Remote on 21 CAN bus connection internal 22 CAN bus connection external 23 Keyboard and mouse ...

Страница 13: ...4 38 16 800x600 60 38 65536 800x600 72 48 65536 800x600 75 47 65536 800x600 85 53 7 65536 800x600 100 63 65536 1024x768 60 48 4 256 1024x768 75 60 256 1024x768 85 68 7 256 1024x768 87 interlaced 36 256 1024x768 100 81 256 1280x1024 87 interlaced 49 16 no 16 color mode The horizontal rate values may have a tolerance range of 0 3 kHz Interrupt table assigned IRQ assigned IRQ System clock IRQ0 free I...

Страница 14: ...termination of the SCSI devices Ultra 2 SCSI connection low voltage differential max 80 Mbyte s Here you can connect SCSI hard disks e g via an SCSI platter in the system unit The termination of the Ultra 2 SCSI connection can be activated and deactivated via the BIOS setup menu item SCSI Termination LVD The default setting is Enabled The termination affects the entire bus width low byte and high ...

Страница 15: ... 1 2 3 4 OPEN OFF ON 1 2 3 4 5 6 7 8 Switch 1 System BIOS recovery Switch 2 must be set to off Switch 3 write protection for system BIOS Switch 4 write protection for floppy disk drive Switch 5 6 7 8 clock frequency i The switch settings apply both to the dual processor system and to the monoprocessor system ...

Страница 16: ...BIOS switch 3 Switch 3 enables and disables system Flash BIOS updating Before an update of the system BIOS can be carried out switch 1 must be set to OFF and write protection for the system BIOS must also be disabled in the BIOS Setup in the Security menu the Flash Write field must be set to Enabled If you wish to update your system BIOS please consult our customer service center OFF System BIOS c...

Страница 17: ...ow for the particular processors used Processor with 100 MHz system bus clock frequency processor switch 5 switch 6 switch 7 switch 8 350 MHz on off off on 400 MHz on on on off 450 MHz on off on off 500 MHz on on off off 550 MHz on off off off 600 MHz off on on on 650 MHz off off on on 700 MHz off on off on 750 MHz off off off on 800 MHz off on on off ...

Страница 18: ... Second processor optional 6 Voltage converter for processor 2 7 Temperature sensor for processor 1 8 Temperature sensor for processor 2 9 First processor 10 Lithium battery 11 Flash BIOS 12 ISA slot 13 PCI slots from below 1 2 3 4 5 6 14 AGP slot i PCI slots 1 2 and 3 are connected to the PCI bus 0 PCI slots 4 5 and 6 are connected to the PCI bus 2 The AGP slot is connected to PCI bus 1 The PCI s...

Страница 19: ...he memory module into the location Ê At the same time flip the lateral holders upwards until the memory module snaps in place Removing a memory module Ê Flip the holders to the right and left of the location outwards Ê Pull the memory module out of its location Replacing the processor You can replace the processor in the slot of the first processor The system board can be upgraded by a second proc...

Страница 20: ...sp the processor housing by the processor and the heat sink 2 2 1 1 1 2 2 1 The illustration shows two bracket and processor models Ê Remove the terminating board if necessary Ê Slide the processor into the bracket 1 Ê Push the processor down in the bracket and press it into the slot until the clamps 2 to the left and right snap into place Ê Set the clock frequency of the new processor using switc...

Страница 21: ...tajan suosittelemaan tyyppiin Hävitä käytetty paristo valmistajan ohjeiden mukaisesti VARNING Explosionsfara vid felaktigt batteribyte Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera använt batteri enligt fabrikantens instruktion ADVARSEL Lithiumbatteri Explosionsfare ved fejlagtig håndtering Udskiftning må kun ske med batteri af samme fabrikat og t...

Страница 22: ...Memory FDC Floppy Disk Controller FIFO First In First Out FSB Front Side Bus FWH Firmware Hub GMCH Graphics and Memory Controller Hub I2 C Inter Integrated Circuit IAPC Instantly Available Power Managed Desktop PC Design ICH I O Controller Hub IDE Intelligent Drive Electronics IPSEC Internet Protocol Security ISA Industrial Standard Architecture LAN Local Area Network LSA LAN Desk Service Agent MC...

Страница 23: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Отзывы: