Troubleshooting and tips

No mouse pointer displayed on the screen

Cause

Remedy

The mouse is not correctly connected.

Shut down the operating system properly.

Switch the device off.

Check that the mouse cable is properly
connected to the system unit. If you use an
adapter or extension lead with the mouse
cable, check the connections.

Switch the device on.

The mouse controller is not enabled.

Check in the

BIOS-Setup

whether the mouse

controller is

enabled

.

Check that the mouse driver is properly
installed and is present when the application
programme is started. Detailed information
can be found in the user guide for the mouse
and application programme.

Time and/or date is not correct

Cause

Remedy

Time and date are incorrect.

Set the correct time and date within the
operating system you are using.

or

Set the correct time and/or date in the

BIOS Setup

.

The lithium battery is discharged.

If the time and date are repeatedly wrong
when you switch on your device, replace the
lithium battery (see

"Replacing the lithium

battery", Page 70

).

Error messages on the screen

Error messages and their explanations are provided:

in the technical manual for the mainboard

in the documentation for the programs used

Installing new software

When installing programs or drivers, important

fi

les may be overwritten and modi

fi

ed. To

be able to access the original data in the event of any problems following installation,
you should backup your hard disk prior to installation.

32

Fujitsu

Содержание CELSIUS M720

Страница 1: ...System Operating Manual CELSIUS M720 CELSIUS M730 ...

Страница 2: ...tp www fujitsu com fts You can find driver updates at http support ts fujitsu com download Should you have any technical questions please contact our Hotline Service Desk see Service Desk list or from the Internet at http support ts fujitsu com contact servicedesk Your sales partner Your sales office We hope you enjoy using your new Fujitsu system ...

Страница 3: ......

Страница 4: ...jitsu Technology Solutions GmbH Mies van der Rohe Straße 8 80807 Munich Germany http www fujitsu com fts Copyright Fujitsu Technology Solutions GmbH 2013 All rights reserved Publication Date 07 2013 Order No A26361 K1399 Z320 1 7619 edition 3 ...

Страница 5: ... M720 CELSIUS M730 Operating Manual Your CELSIUS 5 Ports and operating elements 7 Important notes 10 Getting started 14 Operation 22 Troubleshooting and tips 30 System expansions 34 Technical data 71 Index 72 ...

Страница 6: ... America and other countries PS 2 is a registered trademark of International Business Machines Inc Pentium is a registered trademark of Intel Corporation USA Kensington and MicroSaver are registered trademarks of ACCO Brands Microsoft and Windows are trademarks or registered trademarks of the Microsoft Corporation in the United States and or other countries All other trademarks specified here are ...

Страница 7: ... to the mains 15 Connecting external devices 16 Cable connecting 16 Disconnecting cables 16 Ports on the device 17 Connecting a monitor 18 Connecting the mouse 19 Connecting the keyboard 19 Connecting external devices to the USB ports 20 Switching on for the first time installing the software 20 Switching on monitor and device 21 Installing the software 21 Operation 22 Switch the device on 22 Swit...

Страница 8: ...ng a 3 reader in a 3 bay optional SmartCard or MultiCard 41 Removing the module holder 42 Screwing the reader onto the module holder 42 Installing a module holder with reader 43 Removing a module holder with reader 44 Removing the reader from the module holder 44 Installing and removing a WLAN module optional 45 Removing the front panel 45 Removing the front fan 45 Installing the WLAN module 47 Re...

Страница 9: ...he operating system is preinstalled on your hard disk e g Windows 7 Further information on this device is also provided in the Quick Start Guide poster in the Safety regulations manual in the Warranty manual in the operating manual for the monitor in the manual for the mainboard in the documentation for your operating system in the information files e g PDF HTML DOC CHM TXT HLP Some of the manuals...

Страница 10: ... or a command used to start a program start exe This font indicates information that is displayed on the screen by a program e g Installation is complete This font indicates terms and texts used in a software interface e g Click on Save names of programs or files e g Windows or setup exe This font indicates cross references to another section e g Safety information cross references to an external ...

Страница 11: ...components before starting to work with your device After this section only the CELSIUS M730 is illustrated as the procedure for both models is identical with the exception of the removal of the hard disk front panel CELSIUS M720 Front 1 2 3 4 5 6 7 8 1 Module bays for 51 4 drives 2 Module bays for 31 2 drives 3 ON OFF switch 4 Headphone port 5 Microphone jack 6 USB ports 2 x USB 3 0 2 x USB 2 0 7...

Страница 12: ...rnal devices device dependent 3 Slot covers CELSIUS M730 Front 1 2 3 4 5 6 7 8 1 Module bays for 51 4 drives 2 Module bays for 31 2 drives 3 ON OFF switch 4 Headphone port 5 Microphone jack 6 USB ports 2 x USB 3 0 2 x USB 2 0 7 Hard disk front panel removable 8 Casing lock optional 8 Fujitsu ...

Страница 13: ...Ports and operating elements Rear 1 2 3 1 Alternating voltage socket AC IN 2 Ports for external devices device dependent 3 Slot covers Fujitsu 9 ...

Страница 14: ...e power socket so that the mains voltage is completely disconnected Operate the device only with the casing closed Replace the lithium battery on the mainboard in accordance with the instructions in Replacing the lithium battery Page 70 Caution components in the system can get very hot The activities described in these instructions must always be performed with the greatest care Repairs to the dev...

Страница 15: ... Water entering into the device could present a serious risk to users e g electric shock Ensure that no liquid enters the system The surface can be cleaned with a dry cloth If particularly dirty use a cloth that has been moistened in mild domestic detergent and then carefully wrung out Use disinfectant wipes to clean the keyboard and the mouse Energy saving disposal and recycling Disposal Energysa...

Страница 16: ...s a device with radio components You can find more information and declarations of conformity on the Internet at http globalsp ts fujitsu com sites certificates This equipment can be used in the following countries Belgium Bulgaria Denmark Germany Estonia Finland France Greece UK Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Netherlands Norway Austria Poland Portuga...

Страница 17: ...nt and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those ...

Страница 18: ...rstuse overview Preparingforuse Only a few steps are necessary to put your new device into operation for the first time Select a location for device and set up device Connect external devices such as mouse keyboard and monitor Check the voltage at the mains outlet and connect the device to an electrical outlet Switch the device on You will learn more about the individual steps in the following sec...

Страница 19: ... other devices on casing sides without ventilation surfaces In order to avoid overheating do not cover the ventilation areas of the monitor or the device A minimum distance of 200 mm 7 87 from the device must be observed for ventilation areas Do not stack several devices on top of each other Do not expose the device to extreme ambient conditions see Technical data Page 71 section Ambient condition...

Страница 20: ...vice and peripherals Please make sure that you always observe the safety notes provided in Important notes Page 10 Plug all data communication cables into the sockets provided for the data telecommunication networks Plug all power cables into the grounded mains outlets USB devices are hot pluggable This means you can connect and disconnect USB cables while your device is switched on Additional inf...

Страница 21: ...one port pink back of device or black front of device Microphonejack VGA monitor connection blue Monitorport Audio input Line in light blue Audioinput Linein Headphones light green back of device or black front of device Headphones PS 2 mouse port green Mouseport PS 2mouseport Audio output Line out light green Audiooutput Lineout LAN LAN port LANport USB Universal Serial Bus black UniversalSerialB...

Страница 22: ...apter the integrated display adapter is first deactivated when the optional display adapter is attached You need to activate this function first in the BIOS Setup 1 1 Monitor ports of the display adapter Only attach the monitor to your device when it is switched off Follow the instructions contained in the monitor manual to prepare the monitor for operation e g connecting cables Plug the data cabl...

Страница 23: ...connect a USB keyboard or a PS 2 keyboard to your device Keyboard Connecting Connecting a USB keyboard Use the supplied keyboard cable only USBport Connecting Plug the rectangular connector of the keyboard cable into the rectangular socket on the underside or on the rear of the keyboard Insert the flat rectangular USB plug of the keyboard cable into one of the device s USB ports USBport Connecting...

Страница 24: ...ce to the USB port of your device must not be longer than 3 m The USB port for USB 3 0 is located on the front of your device Switching on for the first time installing the software Installing Software Installing Once the installation has been started the device must not be switched off unless the installation has been completed During installation the device may only be rebooted when you are requ...

Страница 25: ... power indicator lights up and the device starts Installing the software During installation follow the on screen instructions Software Installing If anything is unclear regarding the data you are asked to input read the online Help in your operating system You will find more information on the system as well as drivers utilities and updates on the Drivers Utilities DVD and on the Internet at http...

Страница 26: ...tion Device Monitor or Briefly press the ON OFF switch If the operating system does not automatically switch the device into energy saving mode or switch it off press the ON OFF switch until the device switches off Warning this could lead to a loss of data If the device is switched off the device consumes a minimum of energy The ON OFF switch does not disconnect the device from the mains voltage T...

Страница 27: ...icators on the device The indicators are on the front of the casing Which indicators are available on your device depends on the configuration level you have selected CELSIUS M720 1 2 3 CELSIUS M730 1 2 3 Fujitsu 23 ...

Страница 28: ...d The device is switched on The indicator is flashing The device is in energy saving mode After being switched on with the ON OFF switch the device powers up or returns to the state it was in before it entered energy saving mode The indicator is not illuminated the device is switched off power switch at 0 or disconnected from the mains or is ready If the device is ready it can be switched on with ...

Страница 29: ...tails of other keys and keyboard shortcuts can be found in the documentation for the relevant application program Key key combination Description ON OFFswitch Button On off switch optional Depending on the setting in the BIOS Setup the device can be switched on or off with this switch Some operating systems allow you to configure additional functions of the ON OFF switch in the Control Panel With ...

Страница 30: ...s of the calculator keypad When the Num Lock indicator is lit the numeric keypad and arithmetic keys are active When the Num Lock indicator is not lit the cursor control functions on the Numeric keypad are active Ctrl Keys Keys Keys Keys Ctrl key performs a special operation when pressed in conjunction with another key The Ctrl key is also called the Control or Control key Alt Ctrl Del Ctrl Alt De...

Страница 31: ...ti theftprotection SecurityLock Chain 1 2 1 Holes for padlock 2 Device for Security Lock Anti theft protection You can protect your device from theft with the Security Lock device 1 and with a Kensington MicroSaver Consult the manual for your Security Lock with the holes 2 and a padlock and chain which you have connected to a fixed object beforehand Lead sealing To prevent unauthorised persons fro...

Страница 32: ...n the direction of the arrow 2 BIOS setup security functions Securityfunctions BIOSSetup The Security menu in BIOS Setup offers you various options for protecting your personal data against unauthorized access e g Prevent unauthorized access to BIOS Setup Prevent unauthorised system access Prevent unauthorised access to the settings of boards with their own BIOS Activate virus warnings Protect BIO...

Страница 33: ...d to those users who have a corresponding SmartCard Operating the SmartCard reader optional Operation of this module is not permitted in Taiwan Connect the external SmartCard reader to your system as described in the instructions for the SmartCard reader SmartCardreader After the device is switched on you will be prompted to insert your SmartCard Fujitsu 29 ...

Страница 34: ...e or the top of the casing For further clarification of the problem contact the Service Desk for your country see the Service Desk list or visit the Internet at http support ts fujitsu com contact servicedesk When you do this please have ready the identity number and serial number of your system Troubleshooting Power indicator remains off after you have switched on your device Cause Remedy The mai...

Страница 35: ...ust the brightness control For detailed information please refer to the operating manual supplied with your monitor Power cable not connected Switch off the monitor and the device Check that the monitor power cable is properly connected to the monitor and to a grounded mains outlet or to the monitor socket of the device Check that the device power cable is properly plugged into the device and a gr...

Страница 36: ... application programme Time and or date is not correct Cause Remedy Time and date are incorrect Set the correct time and date within the operating system you are using or Set the correct time and or date in the BIOS Setup The lithium battery is discharged If the time and date are repeatedly wrong when you switch on your device replace the lithium battery see Replacing the lithium battery Page 70 E...

Страница 37: ...ns for restoring the contents of the hard disk in the Recovery Guide manual Tips Topic Tip Lack of system resources Close unnecessary applications or Run the applications in a different order Other manuals Further manuals are provided as PDF files on the Drivers Utilities DVD Fujitsu 33 ...

Страница 38: ...nding on its configuration level If further documentation was delivered with your device please also read this through carefully In addition before removing or installing system components please pay attention to the following The device must be switched off when installing removing the system expansions and may not be in energy saving mode Remove the power plug before opening the device Be carefu...

Страница 39: ...ve boards Make sure expansion boards are inserted straightly Never use sharp objects screwdrivers for leverage Boards with electrostatic sensitive devices ESD are identifiable by the label shown When handling boards fitted with ESDs you must always observe the following points You must always discharge static build up e g by touching a grounded object before working The equipment and tools you use...

Страница 40: ...ant notes Page 10 Disconnect the mains plug from the mains outlet Only insert the power plug after you have closed the casing Remove any connected wires which are in the way On devices with a casing lock Unlock the casing Lay the device on its side in the manner shown 2 1 Pull the locking device 1 and swivel the side part in the direction of the arrow 2 36 Fujitsu ...

Страница 41: ...The casing can accommodate multiple accessible and non accessible drives two drive bays for accessible 51 4 drives two drive bays for accessible 31 2 drives Drive bays for multiple non accessible 21 2 and 31 2 drives hard disks four 21 2 inch drives Standard or four 31 2 inch drives Standard or two 31 2 drives and two 21 2 drives optional or eight 21 2 inch drives optional Accessible drives are e ...

Страница 42: ...36 To use the latch function of the accessible 51 4 inch drive you must fit the corresponding drive cover before installing the drive in the casing Proceed as follows 2 3 1 Unlock the drive cover 1 Push the drive metal plate upwards 2 so it is released from the catches with which it is secured Lift the drive cover away from the casing 3 1 Connect the drive cover to the drive 1 38 Fujitsu ...

Страница 43: ...ve cover for the 5 1 4 inch drive Page 38 Do not throw away the cover For cooling and protection against fire you must refit the cover if you remove the drive again later see Removing an accessible drive Page 40 1 Slide the accessible drive together with the attached drive metal plate into the casing until it engages 1 Connect the cables to the drive Make sure the polarity is correct Close the cas...

Страница 44: ...he casing is open see Opening the casing Page 36 2 1 Disconnect the cables connected to the drive Slide the clip in the direction of the arrow 1 Pull the drive out of the casing in the direction of the arrow 2 1 Remove the drive cover from the drive 1 40 Fujitsu ...

Страница 45: ...essary to modify the entry for the drive in the BIOS Setup Installing removing a 3 reader in a 3 bay optional SmartCard or MultiCard Operation of the module is not permitted in Taiwan You can for instance install a SmartCard or MultiCard reader in the 3 drive bay The reader is mounted onto a module holder when installed in the casing SmartCard or MultiCard readers can be mounted on a module holder...

Страница 46: ... holder 1 1 Remove the screws 1 on the module holder Slide the module holder out of the casing in the direction of the arrow 2 Screwing the reader onto the module holder 2 2 a a 1 With the component side facing downwards slide the reader in the direction of arrow 1 into the guide on the module holder a Fasten the reader with the screws 2 42 Fujitsu ...

Страница 47: ...2 1 Push the module holder into the casing in the direction of the arrow 1 Fasten the module holder with the screws 2 Connect the cables to the boards and the mainboard Make sure the polarity is correct Close the casing see Closing the casing Page 37 Fujitsu 43 ...

Страница 48: ...older see Removing the reader from the module holder Page 44 and reinstall the module holder corresponds to Installing a module holder with reader Page 43 or Remove the reader from the module holder see Removing the reader from the module holder Page 44 and install the metal and plastic cover in the drive bay Close the casing see Closing the casing Page 37 Removing the reader from the module holde...

Страница 49: ...WLAN module bay you first need to remove the front panel 1 1 1 2 Lift the locking lugs on the front panel 1 Fold the front panel in the direction of the arrow 2 and remove it from the casing Removing the front fan Requirement open the casing see Opening the casing Page 36 Requirement remove the front panel see Removing the front panel Page 45 To access the WLAN module bay you need to remove the fr...

Страница 50: ...w 1 Lift the card holder off the fan 2 If boards are fitted at the fan remove these 3 see Removing a board Page 63 1 1 5 2 4 6 3 Lift the lower locking lugs of the fan slightly 1 At the same time slide the fan in direction of the arrow 2 To release the left hand locking lug push it in the direction of the arrow 3 46 Fujitsu ...

Страница 51: ...d To prevent the fan from engaging again tilt it slightly in the direction of the arrow 5 Remove the fan from the casing 6 Installing the WLAN module Remove the metal panel The slot for the WLAN module is protected by a metal cover on delivery 1 Break out the pre stamped metal cover 1 with a screwdriver Fujitsu 47 ...

Страница 52: ... module into the slot in the direction of the arrow 1 Ensure that the screw holes on the casing and those on the WLAN module are precisely aligned over one another Secure the WLAN module with the screws 2 Attach the cables to the WLAN module and mainboard 48 Fujitsu ...

Страница 53: ...System expansions Removing the WLAN module Detach the cables from the WLAN module and mainboard 1 1 2 Undo the screws 1 Pull the WLAN module out of the bay the direction of the arrow 2 Fujitsu 49 ...

Страница 54: ...atches of the fan into the grooves a 1 Push the fan in the direction of the arrow 2 until the lower catches engage Make sure that the two upper catches also engage If necessary reinstall the boards previously removed from the fan see Installing a board Page 61 50 Fujitsu ...

Страница 55: ...nsert the upper part of the card holder in the guide 2 and push it to the edge of the guide The upper part of the card holder engages Connect the fan cable to the mainboard Reattach the front panel see Securing the front panel Page 52 Fujitsu 51 ...

Страница 56: ...front panel 1 1 1 a a a Put the front cover onto the guide openings on the right of the casing Fold the front panel in the direction of the arrow 1 until the catches a engage Close the casing see Closing the casing Page 37 52 Fujitsu ...

Страница 57: ...th the optional add on installation kit you receive the necessary EasyChange rails At most you can install the following hard disks four 21 2 inch drives or two 21 2 inch drives and two 31 2 inch drives or four 31 2 inch drives Standard installation kit Alternatively you can purchase an optional installation kit in which you can install up to eight 21 2 inch drives Optional installation kit Fujits...

Страница 58: ...ng a hard disk Page 58 If necessary disconnect the drive cables from the installation kit Press the locking lug to unlock the cable bracket and push the cable bracket to the rear and out of the opening Undo the screws on the old installation kit Remove the installation kit from the casing Position the new installation kit at the bay Fasten the new installation kit with the screws Secure the drive ...

Страница 59: ...k in the casing may vary install either horizontally or vertically depending on the hard disk type The following images illustrate the installation of a 31 2 drive Removing the hard disk front panel CELSIUS M720 1 1 2 CELSIUS M730 1 1 2 Press the unlocking keys on the sides of the hard disk front panel 1 Fold the hard disk front panel in the direction of the arrow 2 and remove it from the casing F...

Страница 60: ...open and the side cover removed see Opening the casing Page 36 If you use a casing with a casing lock the safety guard in front of the drives is also secured against unauthorised opening Requirement remove the protective grille see Removing the protective grille Page 56 EasyChange rails for a second hard disk drive are mounted on the drive cage 56 Fujitsu ...

Страница 61: ...r 21 2 inch drives is installed If you wish to install other or different drives use the supplied cables 1 Slide the hard disk drive with the EasyChange rails into the drive cage in the direction of the arrow 1 Ensure that the label on the 3 hard disk drive is facing the side cover to be opened If you are installing a 2 hard disk drive ensure that the label is on the top Connect the cables to the ...

Страница 62: ... depending on the hard disk type The following images illustrate the installation of a 31 2 drive Removing the hard disk drive Open the casing see Opening the casing Page 36 Remove the hard disk front panel see Removing the hard disk front panel Page 55 Remove the protective grille see Removing the protective grille Page 56 1 1 2 Press the levers of the EasyChange rails which are secured to the ha...

Страница 63: ...drive cage It may be necessary to modify the entry for the drive in the BIOS Setup Securing the protective grille 1 Put the protective grille into the sheet metal lugs on the casing and fold it in the direction of the arrow 1 The protective grille is secured Reattach the front panel to the casing see Securing the hard disk front panel Page 60 Fujitsu 59 ...

Страница 64: ...ring the hard disk front panel CELSIUS M720 1 CELSIUS M730 1 Place the hard disk front panel in the guide openings as illustrated Fold the hard disk front panel in the direction of arrow 1 until you feel it engage 60 Fujitsu ...

Страница 65: ...all display adapters with an additional power connection in the second slot on the right see following illustration Open the casing see Opening the casing Page 36 Board For long PCI boards Remove the upper part of the card holder at the front fan in order to be able to click the board into place at the front fan see Removing the front fan Page 45 1 2 Push the retaining clip 1 towards the slot cove...

Страница 66: ...t the cables to the board For display adapters with additional power supply Attach the display adapter power cable to the power supply For long PCI boards Fit the upper part of the card holder at the front fan again see Installing the front fan Page 50 Close the casing see Closing the casing Page 37 If you have installed or removed a board please check the relevant slot settings in the BIOS Setup ...

Страница 67: ...er part of the card holder at the front fan in order to be able to click the board into place at the front fan see Removing the front fan Page 45 1 2 Push the retaining clip 1 towards the slot cover to unlock it then move it towards back panel of the device Pull the board out of the slot in the direction of the arrow 2 Place the board in suitable packaging Fujitsu 63 ...

Страница 68: ...r information is provided in the PCI board documentation Upgrading main memory Open the casing see Opening the casing Page 36 Mainmemory If the bays are located below the hard disk fan Remove the hard disk fan see Remove the hard disk fan Page 68 If the bays are located below the fan at the power supply Remove the fan at the power supply see Removing the rear fan Page 66 Upgrade the main memory ac...

Страница 69: ...casing see Opening the casing Page 36 Remove the hood of the hard disk fan and the hard disk fan itself see Remove the hard disk fan Page 68 Undo the screws on the heat sink Lift the heat sink out of the casing You can now replace the processor Installing the heat sink Open the casing see Opening the casing Page 36 Reinstall the heat sink so that the air flow is fed towards the back of the casing ...

Страница 70: ...ust remove the rear fan Removing the rear fan Requirement open the casing see Opening the casing Page 36 Disconnect the fan cable from the mainboard 1 2 Press the catch of the fan in the direction of the arrow 1 so that the fan releases from the location Remove the fan from the casing 2 66 Fujitsu ...

Страница 71: ...fan in the casing 1 and ensure that the catch 2 engages in the openings on the back of the device Connect the fan cable to the mainboard Removing and installing the hard disk fan To access the front main memory slots you must remove the hard disk fan Fujitsu 67 ...

Страница 72: ... the mainboard a 1 Swivel the hood in the direction of the arrow 1 until the guide on the fan a fits through the grooves of the hood Unhook the hood Remove the hood from the casing 1 1 2 Move the catches of the fan in the direction of the arrow 1 so that the fan releases from the location Remove the fan from the casing 2 68 Fujitsu ...

Страница 73: ... the hood into the guides on the fan a Carefully fold the hood down 1 until you feel it latch into place Installing a 4 port SAS upgrade ROM Proceed as follows to install the 4 port SAS upgrade ROM mass storage controller Open the casing see Opening the casing Page 36 Plug the upgrade ROM connector into the mainboard refer to the mainboard manual for details Close the casing see Closing the casing...

Страница 74: ...mended by the manufacturer Do not dispose of lithium batteries with household waste They must be disposed of in accordance with local regulations concerning special waste Make sure that you observe the correct polarity when replacing the lithium battery The plus pole must be on the top Lithiumbattery Replacing Replacing Replacing lithiumbattery Battery The lithium battery holder exists in differen...

Страница 75: ... 92 inches Weight in basic configuration approx 11 kg 24 25 lbs Ambient conditions Environment class 3K2 Environment class 2K2 DIN IEC 721 part 3 3 DIN IEC 721 part 3 2 Temperature Operation 3K2 10 C 35 C 50 F 95 F Transportation 2K2 25 C 60 C 13 F 140 F The formation of condensation is not permitted while the device is in operation Clearance required to ensure adequate ventilation without air ven...

Страница 76: ...ng 34 Connecting a PS 2 keyboard 19 Connecting keyboard 19 mouse 19 PS 2 keyboard 19 PS 2 mouse 19 USB keyboard 19 Contents of delivery 14 Cord see Cable 16 Ctrl Alt Del 26 Cursor keys 25 D Data protection 27 Device Connections 17 setting up 15 Device Anti theft protection 27 closing 37 Lead sealing 27 opening 36 switching off 22 switching on 21 22 transporting 10 11 upgrades 34 Devices connecting...

Страница 77: ...ng 15 Microphone jack 17 Monitor port 17 Monitor switching off 22 switching on 21 22 Mouse port 17 Mouse connecting 19 N Note safety 10 Notes CE marking 12 important 10 Numeric keypad 25 O ON OFF switch 25 Overview Device 5 P Packaging 14 Packaging unpacking 14 Ports 7 17 Preparing for first use overview 14 Preparing for use overview 14 Property protection 27 PS 2 mouse port 17 PS 2 mouse connecti...

Страница 78: ...tem unit see Device 11 T Transportation 10 11 U Universal Serial Bus 17 Upgrades device 34 USB devices connecting 20 USB port 19 USB port connecting devices 20 connecting keyboard 19 connecting the mouse 19 User Documentation DVD 11 W Workstation 15 74 Fujitsu ...

Отзывы: