background image

15

OPERATING TIPS

Temperature and Humidity Range

COOLING/DRY MODE

COOLING MODELS

HEAT & COOL

MODELS

(Reverse Cycle)

If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in
ordinary dwellings.

Humidity

About 80 % or less

If the unit is used for long pe-
riods under high-humidity
conditions, condensation
may form on the surface of
the indoor unit, and drip onto
the floor or other objects un-
derneath.

Should the power supply to the air conditioner be inter-
rupted by a power failure, the air conditioner will restart
automatically in the previously selected mode once the
power is restored.

Should a power failure occur during TIMER operation,
the timer will be reset and the unit will begin (or stop)
operating under the new timer setting. In this event, the
TIMER indicator lamp (yellow) will flash (see page 4).

Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
disconnect the power supply, reconnect it, and then use
the remote control unit to resume operation.

AUTO Restart

In Event of Power Interruption

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Temperature

About 18 to 32 

°

C

Outdoor

Temperature

About 21 to 43 

°

C

About 0 to 43 

°

C

About 21 to 43 

°

C

About 0 to 43 

°

C

Outdoor

Unit

AOT18A
AOT24A

AOT30A

AOT14R

AOT18R
AOT24R
AOT30R

Indoor

HEAT & COOL

MODELS

(Reverse Cycle)

Outdoor

Temperature

About 0 to 24 

°

C

About – 5 to 24 

°

C

Outdoor

Unit

AOT14R
AOT18R
AOT24R

AOT30R

Indoor

Temperature

About 30 

°

C or less

*HEATING MODE

Содержание AWT14RB

Страница 1: ...YPE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL Indoor Unit AWT14RB AWT18AB AWT18RB AWT24AB AWT24RB AWT30AB AWT30RB Outdoor Unit AOT14R AOT18A AOT18R AOT24A AOT24R AOT30A AOT30R P N9369307010 ...

Страница 2: ...llation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port...

Страница 3: ...owered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air dire...

Страница 4: ...3 F D E Fig 2 Fig 3 Fig 4 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 6 Fig 1 Fig 8 Fig 7 0 1 4 9 A B 3 7 6 5 8 2 C F D E F D E ...

Страница 5: ...n M START STOP button N AIR FLOW DIRECTION VERTICAL SET button O AIR FLOW DIRECTION VERTICAL SWING button P AIR FLOW DIRECTION HORIZONTAL SET button Q AIR FLOW DIRECTION HORIZONTAL SWING button Rear side Fig 7 R TIME ADJUST button S ACL button located inside battery compartment T TEST RUN button This button is used when installing the air conditioner and should not be used under normal conditions ...

Страница 6: ...t Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Fig 7 R Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons Fig 6 I to adjust the clock to the current time button Press to advance ...

Страница 7: ...ds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 L Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heating Fan...

Страница 8: ... very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to ...

Страница 9: ...on while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The air condition...

Страница 10: ...imer setting During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the thermo stat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 min...

Страница 11: ...th infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Example When set to vertical air direc tion Example When set to horizontal air di rection Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION VERTICAL SET button Fig 6 N Each time the button is pressed the air direction range will change as follows 1 2 ...

Страница 12: ...in the range 4 to 5 for long periods of time since water vapor may condense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button Fig 6 Q The SWING indicator lamp HORIZONTAL SWING Fig 3 8 will light In this mode the RIGHT LEFT air direction louvers will swing automatically to direc...

Страница 13: ... accumulate on the intake filters air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use the intake filters should be cleaned every five weeks 3 Install the intake filters Hang the edge of the intake filter on the body Using this as a support point push forward to secure as shown in the illustration When using the optional Air Cleaning Filter Insta...

Страница 14: ...result of minute expansion and contraction of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry oper...

Страница 15: ... air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat ...

Страница 16: ...ure the air conditioner will restart automatically in the previously selected mode once the power is restored Should a power failure occur during TIMER operation the timer will be reset and the unit will begin or stop operating under the new timer setting In this event the TIMER indicator lamp yellow will flash see page 4 Use of other electrical appliances electric shaver etc or nearby use of a wi...