INDOOR UNIT H x W x D
H x W x D
OUTDOOR UNIT
DIMENSIONS
INDOOR UNIT
OUTDOOR UNIT
WEIGHT
POWER SOURCE
Cooling
RUNNING
CURRENT
Heating
INPUT WATTS
Cooling
Heating
E.E.R.
Cooling
Heating
Cooling
Heating
MOISTURE REMOVAL
AIRCIRCULATION
Outdoor
FAN MOTOR
INDOOR UNIT, Discrimination
High
INDOOR UNIT
Medium
Low
Cooling
Heating
Cooling
Heating
OUTDOOR UNIT, Discrimination
OUTDOOR
UNIT, Upper fan
OUTDOOR
UNIT, Lower fan
TYPE
Cooling & Heating
INDOOR UNIT
AUYA45LCLU
OUTDOOR UNIT
AOYA45LCTL
COOLING CAPACITY
HEATING CAPACITY
288 x 840 x 840 mm
DECORATION PANEL H x W x D
50 x 950 x 950 mm
1,290 x 900 x 330 mm
33 kg / 27 kg
DECORATION PANEL
8.5 kg / 5.5 kg
16.9 A
16.5 A
3.88 kW
3.77 kW
3.22 kW/kW
3.71 kW/kW
4.5 L/hr
6,750 m3/hr
MAXIMUM CURRENT, Cooling
20.5 A
MAXIMUM CURRENT, Heating
20.5 A
AIRCIRCULATION, Indoor
1,900 m3/hr
230 V 50 Hz
MFF-54TVM
690 r.p.m.
610 r.p.m.
550 r.p.m.
Quiet
470 r.p.m.
MFE-45VVT
800 r.p.m.
850 r.p.m.
12.5 kW
14.0 kW
AUYA54LCLU
AOYA54LCTL
19.3 A
20.5 A
4.42 kW
4.69 kW
3.01 kW/kW
3.41 kW/kW
5.0 L/hr
6,750 m3/hr
6,200 m3/hr
6,850 m3/hr
21.5 A
21.5 A
2,000 m3/hr
720 r.p.m.
630 r.p.m.
570 r.p.m.
480 r.p.m.
800 r.p.m.
850 r.p.m.
750 r.p.m.
780 r.p.m.
830 r.p.m.
850 r.p.m.
13.3 kW
16.0 kW
ELECTRICAL DATA
TYPE
DISCRIMINATION
WEIGHT (with oil)
REFRIGERANT TYPE
R410A
PRECHARGED REFRIGERANT
3,350 g
COMPRESSOR AND REFRIGERANT
2011.04.06
1
SPECIFICATIONS
MAX PIPE LENGTH
50 m
MAX PIPE HEIGHT
30 m
Pipe length 20 m
3,350 g
FULL CHARGE
30 m
40 m
50 m
ADDITIONAL CHARGE
NOISE LEVEL
High
INDOOR UNIT
Medium
Low
Cooling
Heating
46 dB
42 dB
40 dB
Quiet
36 dB
OUTDOOR UNIT
55 dB
55 dB
47 dB
43 dB
41 dB
37 dB
55 dB
57 dB
Shipping / Net
Shipping / Net
Shipping / Net
94 kg / 86 kg
Hermetic type, Inverter,
6 poles, 3 phase,
DC motor, Twin Rotary
N-TF30HD1A
15.4 kg
3,750 g
4,150 g
4,550 g
40 g/m