10-3. Function settings on wired remote controller
By using some components on the wired remote controller, you can change the function settings re-
lated on the remote controller.
¢
Component location
Components on the wired remote controller used for the function settings are located as shown
in the following figure.
NOTE:
Do not use DIP switch 2.
ON
ON
OFF
1
2
3
4
5
6
Front case (back side)
DIP switch 2
(All switches are fixed at OFF.)
DIP switch 1
¢
DIP switch setting
By switching each slide switch on the DIP switch 1, you can change the function settings for the
remote controller.
DIP switch 1
SW1
Setting change prohibited*
SW2
Dual remote controller setting
SW3
Setting change prohibited*
SW4
°F / °C switch
SW5
Setting change prohibited*
SW6
Memory backup setting
*: Switches are fixed at OFF initially.
•
SW2: Dual remote controller setting
Number of remote controller can be changed.
Number of remote
controller
Primary unit
Secondary unit
Factory setting
SW2
SW2
1 (Normal)
OFF
―
♦
2 (Dual)
OFF
ON
1 2 3
1 2 3
1 2 3
Indoor unit
Primary unit
Secondary
unit
Remote controllers
Remote controller cable