OPERATING TIPS

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

*Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low
outdoor temperature and high humidity, frost may form
on the outdoor unit, resulting in reduced operating per-
formance.

In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Auto-
matic Defrosting function. If frost forms, the air condi-
tioner will temporarily stop, and the defrosting circuit will
operate briefly (for about 4 to 15 minutes).

During Automatic Defrosting operation, the OPERATION
indicator lamp will flash.

*Low Ambient Cooling

When the outdoor temperature drops, the outdoor unit’s
fans may switch to Low Speed.

*Hot start (for heating)

The indoor unit prevents cold drafts when heating opera-
tion begins.
The indoor unit fan will not operate or it will operate at a
very low speed until the heat exchanger reaches the set
temperature.

*Heating Performance

This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.

Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.

*When Indoor and Outdoor Temperature are High

When both indoor and outdoor temperatures are high
during use of the heating mode, the outdoor unit’s fan
may stop at times.

*Fan speed: AUTO

Heating: The fan will operate at very low speed when the

temperature of the air issued from the indoor unit
is low.

Cooling: As the room temperature approaches that of the

set temperature, the fan speed becomes slower.

Fan:

The fan runs at the low fan speed.

HEAT & COOL MODEL (Reverse Cycle)

Auto changeover function

When AUTO CHANGEOVER is selected, the air conditioner
selects the appropriate operation mode (Cooling or Heat-
ing) according to your room’s present temperature.

When AUTO CHANGEOVER is first selected, the fan will
operate at a very low speed for about 1 minute while the
unit determines the current conditions of the room and
selects the proper operation mode.

If the difference between thermostat setting and actual
room temperature is more than +2 °C

Cooling or dry operation
(Monitor operation may be selected if the outdoor tem-
perature is low.)

If the difference between thermostat setting and actual
room temperature is within ±2 °C

Monitor operation

If the difference between thermostat setting and actual
room temperature is more than –2 °C

Heating operation
(Monitor operation may be selected if the outdoor tem-
perature is high.)

Mode operation: AUTO

COOLING MODEL

When the room temperature is 2 °C higher than the set
temperature, the mode will switch between Cooling and
Drying.

During the Drying mode operation, the FAN setting should
be switched to LOW for a gently cooling effect during
which the fan may temporarily stop rotating.

When the room temperature is near the thermostat set-
ting, the air conditioner will begin monitor operation. In
the monitor operation mode, the fan will operate at a very
low speed. If the room temperature subsequently
changes, the air conditioner will once again select the
appropriate operation (Heating or Cooling) to adjust the
temperature to the value set in the thermostat. (The moni-
tor operation range is ±2 °C relative to the thermostat
setting.)

Содержание AUT Series

Страница 1: ...OPERATING MANUAL P N9374379309 KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED AIR CONDITIONER CASSETTE TYPE AUT Series ...

Страница 2: ...not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at least one metre away from either the in door or ou...

Страница 3: ...ion When the set time is reached the unit automatically turns off HEAT COOL MODEL REVERSE CYCLE When the SLEEP timer button is pressed during Heating mode the air conditioner s thermostat setting is gradu ally lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatical...

Страница 4: ...ll cause the air condition er s thermostat function to operate incorrectly If this button is pressed during normal opera tion the unit will switch to test operation mode and the Indoor Unit s OPERATION In dicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation mode press the START STOP button to stop the air condi tioner F Signal Transmitter G Temperatur...

Страница 5: ...it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time button Press to advance the time butt...

Страница 6: ...utton Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches...

Страница 7: ...r conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter...

Страница 8: ...time or ON time Set the time while the time display is flashing the flashing will continue for about five seconds button Press to advance the time button Press to reverse the time About five seconds later the entire display will reappear To Use the Program timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION Indicator Lamp will light 2 ...

Страница 9: ...mostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered 1 C every thirty minutes When th...

Страница 10: ...stop op eration and restart The louvers should begin to operate properly again When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Horizontal Air Direction Adjustment SWING OPERATION Left right and up down left right swing operation cannot be performed on models that are not equipped with hori...

Страница 11: ...e cooling mode dehumidification is improved This function is especially convenient when you want to remove the humidity in the room without significantly lowering the room temperature During ECONOMY operation the thermostat setting automatically changes according to the temperature to avoid Unneces sary cooling and heating for the most economical operation If the room is not cooled or heated well ...

Страница 12: ... a period of one month or more be sure to allow the inner parts of the unit to dry thoroughly in advance by operating the unit in fan mode for half a day Intake Grille Air Filter Filter Hook 3 Clean the air filters Remove the dust from the air filters by vacuuming or washing them After washing allow the air filters to dry thoroughly in an area protected from sunlight 4 Re attach the air filters to...

Страница 13: ...ct the power supply plug ro turn off your circuit breaker to ensure that power is completely off Before requesting service perform the following checks Symptom Doesn t operate immedi ately Noise is heard Problem If the unit is stopped and then immediately started again the com pressor will not operate for about 3 minutes in order to prevent fuse blowouts Whenever the power supply plug is disconnec...

Страница 14: ... the Automatic Defrosting mode operates During the Automatic Defrosting operation the OPERA TION indicator lamp will flash The fan may operate at very low speed during Dry operation or when the unit is monitoring the room s temperature During QUIET operation the fan will operate at very low speed In the monitor AUTO operation the fan will operate at very low speed During Heating operation water ma...

Страница 15: ...or unit s fan may stop at times Fan speed AUTO Heating The fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the set temperature the fan speed becomes slower Fan The fan runs at the low fan speed HEAT COOL MODEL Reverse Cycle Auto changeover function When AUTO CHANGEOVER is selected the air condi...

Страница 16: ...her electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily disconnect the power supply plug reconnect it and then use the remote control unit to resume operation AUTO Restart In Event of Power Interruption Multi type Air conditioner This indoor unit can be connected to a multi type outdoor unit ...

Страница 17: ...oor unit A would temporarily start opera tion in fan mode but when indoor unit B started oper ating in heating mode the OPERATION indicator lamp for indoor unit A would begin to flash 1 second on 1 second off and it would go into standby mode Indoor unit B would continue to operate in heating mode OPERATING TIPS TEMPERATURE AND HUMIDITY RANGE Cooling Dry Operation Heating Operation Outdoor tempera...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: