13
2006.01.20
When the fault is cleared, the LED lamp goes off.
When a malfunction occurs in the outdoor unit, the LEDs on the circuit
board light to indicate the error. Refer to the following table for the descrip-
tion of each error according to the LEDs.
Quick flash continued
Quick flash continued
Model abnormal or EEPROM
abnormal
0.1 sec.
OFF
ON
0.1 sec.
OFF
ON
2 quick flash repeated
Dislighting continued
UNIT A
Discharge temperature sensor error
3 quick flash repeated
Dislighting continued
UNIT A
Outdoor heat exchanger temperature
sensor error
0.5 sec.
2 sec.
OFF
ON
0.5 sec.
2 sec.
OFF
ON
4 quick flash repeated
Dislighting continued
Outdoor temperature sensor error
5 quick flash repeated
Dislighting continued
UNIT A
Communication signal error
6 quick flash repeated
Dislighting continued
UNIT A
Indoor unit error
7 quick flash repeated
Dislighting continued
UNIT A
Discharge temperature abnormal
UNIT B
Discharge temperature sensor error
UNIT B
Outdoor heat exchanger tempera-
ture sensor error
Dislighting continued
5 quick flash repeated
UNIT B
Communication signal error
Dislighting continued
6 quick flash repeated
UNIT B
Indoor unit error
2 quick flash repeated
3 quick flash repeated
0.5 sec.
2 sec.
OFF
ON
0.5 sec.
2 sec.
OFF
ON
Dislighting continued
Dislighting continued
Dislighting continued
7 quick flash repeated
UNIT B
Discharge temperature abnormal
OUTDOOR UNIT
Error display
Error contents
LED 1
LED 2
Содержание AUH12UMAB
Страница 6: ...OUTDOOR UNIT Model AOH20USBV2 Unit mm Air Flow 40 900 700 21 9 400 330 31 12 370 650 5 2006 03 01 ...
Страница 19: ...Model AUH12UMAB 18 2006 03 01 ...
Страница 21: ...Model AOH20USBV2 20 2006 03 01 1 10 4 2 3 5 6 9 ...
Страница 22: ...21 2006 03 01 18 15 25 23 24 11 12 19 13 14 Model AOH20USBV2 ...
Страница 23: ...22 2006 03 01 40 36 39 42 41 37 38 35 Model AOH20USBV2 29 33 34 28 1 28 2 31 32 30 27 ...
Страница 24: ...Model AOH20USBV2 23 2006 03 01 56 52 53 54 48 2 48 1 49 47 50 46 55 51 57 ...
Страница 30: ...0602G3028 ...