Fujitsu ASY14FSBCW Скачать руководство пользователя страница 1

KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE

English

Deutsch

Français

Español

Italiano

EλληvIkά

OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D’EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI

ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

MANUAL DE INSTRUÇÕES

P/N9313732011-0

2

ROOM AIR CONDITIONER

WALL MOUNTED TYPE

COOLING MODEL

Por

tuguês

Содержание ASY14FSBCW

Страница 1: ...tsch Français Español Italiano EλληvIkά OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES P N9313732011 02 ROOM AIR CONDITIONER WALL MOUNTED TYPE COOLING MODEL Português ...

Страница 2: ...ppliance is damaged it should only be replaced by the authorized service personal since special purpose tools and specified cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air con...

Страница 3: ...itioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER QUIET O...

Страница 4: ...ET TEMP SET TIME buttons N Signal Transmitter O TIME ADJUST button P SET TIMER button Q FAN CONTROL button R START STOP button S SET button T SWING button U ACL button located inside battery compartment Rear Side Fig 7 V TEST RUN button Touch the two metal contacts with a me tallic object to send the signal to perform a test run Perform a test run only when installing the air conditioner If the si...

Страница 5: ...s and slide the battery compartment lid on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the TIME ADJUST button Fig 6 O Use the tip of a ball point pen or other small object to press the button 2 Use the SET TEMP SET TIME b...

Страница 6: ...setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermos...

Страница 7: ...g mode has been set the mode will not change even if the room temperature changes If the START STOP button is pressed to recommence operation within two hours after stopping automatic operation the unit will begin op erating from the same mode as before About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during Dry mo...

Страница 8: ... PROGRAM OFF ON OFF ON The indoor unit sTIMER Indicator Lamp green Fig 3 6 will light 3 Use the SET TEMP SET TIME button Fig 6 M to ad just the desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about five seconds button Press to advance the time button Press to reverse the time About five seconds later the entire display will reappear To Use...

Страница 9: ...ut five seconds later the entire display will reappear To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Stop the Air Conditioner During Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accord ance w...

Страница 10: ...y modes if the louvers are operated outside the range 1 3 for more than 30 minutes they will be automatically returned to the 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Fig 6 S Each time the button is pressed the air direc...

Страница 11: ...e event the Remote Controller is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop operation press the MANUAL AUTO button once again Controls are located inside the Intake Grille When the air conditioner is operated with the controls on the Main Unit it will operate under the same mode as the AUTO mode select...

Страница 12: ...holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is allowed to accumu...

Страница 13: ...Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in con densation and misting The fan may operate at very...

Страница 14: ...Remote Controller s batteries loaded properly OPERATING TIPS The air conditioner power has been interrupted by a power failure The air conditioner will then restart automatically in its previous mode when the power is restored Operated by setting before the power failure If the problem persists after performing these checks or if you notice burning smells or the TIMER indicator Lamp Fig 3 6 flashe...

Страница 15: ...ditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor o...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Отзывы: