background image

En-6

OPERATING MANUAL

 Remote controller custom code setting

When two or more air conditioners are installed in a room and the 
remote controller is operating an air conditioner other than the one you 
wish to set, change the custom code of the remote controller to operate 
only the air conditioner you wish to set (4 selections possible).
When two or more air conditioners are installed in a room, please 
contact your retailer to set the individual air conditioner custom codes.
Use the following steps to select the custom 
code of the remote controller.
(Note that the air conditioner cannot receive 
a signal if the air conditioner has not been set 
for the matching custom code.)

the clock is displayed on the remote 
controller display.

seconds to display the current custom code (initially set to A).

3.   Press the SET TEMP. (  /  ) button to change the custom code 

 Match the code on the display to the air conditioner custom code.

4.   Press the MODE button again to return to the clock display. The 

custom code will be changed.

•  If no buttons are pressed within 30 seconds after the custom code 

is displayed, the system returns to the original clock display. In this 

•  The air conditioner custom code is set to A prior to shipment.
   Contact our authorized service personnel to change the custom code.
•  Depending on the remote controller, the custom code may return to 

custom code A when the batteries are replaced. In this case, if you 
use a code other than A, reset the code after replacing the batter
ies. If you do not know the air conditioner custom code setting, try 

air conditioner.

 Wired Remote Controller (Option)

The optional wired remote controller can be used.

compared with using wireless remote controller.

[The additional functions for wired remote controller]
  • Temperature set back timer

And, you can use wired and wireless remote controller together.
However, you must change some restricted functions of wireless remote 
controller to invalid.
If restricted function is valid, remote controller cannot use correctly.
(beeping sound will be heard, OPERATION, TIMER and the ECONOMY 

[The restricted functions for wireless remote controller]

• Outdoor unit low noise
• Energy saving

• Powerful
• Timer operation

Timer Operation

ON timer or OFF timer

You can set the ON timer or OFF timer with the following steps.

1

  Press the "TIMER SETTING" button to start the setting. 

2

  Press the "SELECT" button to choose the desired mode. The 

WEEKLY

ON/OFF 

(ON)

ON/OFF 

(OFF)

ON/OFF 

(ON

OFF)

SLEEP 

(OFF)

3

* To cancel timer setting during the setting process, press the 

"TIMER SETTING" button again.

4

  Adjust the time by pressing the "SELECT" button while the clock 

indicator is blinking. Each time you press the button, the time will 

5

  Press the "SEND" button.

To cancel the ON/OFF timer, press the "ON/OFF" button while the ON/
OFF indicator is on. (Erases the indicator)

Program timer (combined use of the ON timer and the OFF timer)

Timer

Indicator on remote controller display

To set the program timer, conduct the same steps  ~  for the ON/
OFF timer. (Select ON OFF in Step 2)

Notes:

• If you change the setting value for the timer after the program timer 

is set, the counting down of the timer will be reset at that moment.

• Time setting for each combination should be within a span of 24 hours.

SLEEP timer

~  for the ON/OFF timer.

4

  Adjust the time by pressing the "SELECT" button while the clock 

indicator is blinking. 

hours

(30 min.)

5

  Press the "SEND" button.

To cancel the SLEEP timer, press the "SLEEP" button while the 
SLEEP indicator is on. (Erases the indicator)

To help you to fall asleep comfortably and prevent excessive warming 
or cooling in sleep, the SLEEP timer controls the temperature setting 
automatically in accordance with the set time shown as follows. The 

In HEAT mode

Set 
temperature

Set time

Set time

30 min.

In COOL or DRY mode

(continued)

Note for timer settings:

of a circuit breaker, makes the set internal clock go wrong.
In such a case, the TIMER indicator on the indoor unit blinks, and 
you need to readjust the setting.

Содержание ASTG30KMTB

Страница 1: ...tion or handling will cause leakage electric In the event of a malfunction such as burning smell immediately stop operation of the air conditioner and breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the in order to avoid a hazard In the event of refrigerant leakage ...

Страница 2: ... damage or malfunction of your property Do not expose this product directly to water Do not use this product for preservation of food plants animals precision equipment art work or other objects This may cause quality deterioration of those items Do not drink the drainage from the air conditioner Do not pull the power supply cable product to avoid personal injury when you install or maintain the u...

Страница 3: ...5 4 Do not adjust by hand At the beginning of AUTO or HEAT mode they may stay on position or DRY mode the louver will automatically return to position 3 condensation to form and the drops may damage your property 7 Each time you press the Horizontal SET button on the remote 1 2 3 4 5 5 4 1 3 2 8 Drain hose 9 CAUTION For appropriate signal transmission between remote controller and indoor unit keep...

Страница 4: ...re needs to be set higher than the current room temperature Otherwise corresponding operation mode may not start Temperature setting range AUTO COOL DRY HEAT Notes Temperature control is not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows th...

Страница 5: ...r the initial test in the unit installation Do not press this button under normal use because it will cause incorrect operation During the test run the OPERATION indicator and the TIMER indicator blink simultaneously To quit the test run that is started unintentionally you need to turn See page 2 19 CLOCK ADJUST button Used for adjusting the clock 20 SEND button Used for sending the timer clock se...

Страница 6: ... functions of wireless remote controller to invalid If restricted function is valid remote controller cannot use correctly beeping sound will be heard OPERATION TIMER and the ECONOMY The restricted functions for wireless remote controller Outdoor unit low noise Energy saving Powerful Timer operation Timer Operation ON timer or OFF timer You can set the ON timer or OFF timer with the following step...

Страница 7: ...r setting or a circuit breaker cutting out See page 2 remote controller preparation You cannot use the WEEKLY timer together with the other timers If you want to run the product on WEEKLY timer after using the ON OFF Timer Program Timer or SLEEP Timer while the WEEKLY timer is running you need to activate the WEEKLY timer again To set the WEEKLY timer first follow steps for the ON OFF timer 4 Sele...

Страница 8: ...e there When there is a dog or a cat moving around in the room When the wind is making curtains or plants move ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your e...

Страница 9: ... the remote controller Heating performance absorbing heat from air outdoors and transferring that heat to the indoor unit As a result the operating performance is reduced as outdoor air temperature drops If you feel that the this air conditioner in conjunction with other kinds of heating appliance Wired remote controller option The optional wired remote controller can be used as compared with usin...

Страница 10: ...he arrow c 2 Wash the intake grille gently with water or wipe it gently with a soft cloth moisten with warm water Then wipe it with a dry and soft cloth 3 While holding the grille horizontal set the left and right mounting shafts into the pillow blocks at the top of the panel d To latch each shaft properly insert the shaft until it snaps Then close the intake grille e 4 Press 4 places on the intak...

Страница 11: ... 3 months 1 2 Clean with water and dry in the air neutral detergent Never wash by reaming or rubbing otherwise it will damage 3 Dry in shade 3 After extended non use of the unit FAN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance...

Страница 12: ...emitted automatic defrosting operation may be seen Immediately after the heating operation is started the fan speed stays very low temporarily to warm up the internal parts of the unit In HEAT mode the outdoor unit stops and the indoor unit operates at very low fan speed if the room temperature rises above the set temperature In DRY mode the indoor unit operates at low fan speed to adjust the room...

Отзывы: