Timer Operation (continued)

 WEEKLY timer

ON and OFF timer can be combined, and up to 4 reservations (program 

 ) per day and 28 reservations per week.

Before setting the program, please set the week and time of the air 
conditioner 

fi

 rst.

If the week and time are not set, the weekly timer will not operate 
correctly at the set time.
Please refer to "remote controller preparation"  (page 2).

Example of WEEKLY timer 1

No timer settings

Program 

9:00  

OFF

Program 

11:00  

OFF

Program 

17:00  

OFF

Program 

23:00  

OFF

Monday to 

Friday

Saturday

Sunday

Program 

7:00 

ON 

24.0°C

Program 

9:00 

OFF

Wake up

Leave for work

Program 

17:00 

ON 

26.0°C

Program 

23:00 

OFF

Come back home

Go to sleep

ON

ON

ON

ON

Example of WEEKLY timer 2

You can specify a given temperature in the ON setting in WEEKLY 
timer.

Program 
7:00 

ON 

22.0°C

Program 
9:00 

ON 

24.0°C

Program 
17:00 

ON 

26.0°C

Program 
23:00 

ON 

22.0°C

* You can set the temperature for AUTO, COOL, and DRY modes 
within the range of 18.0-30.0°C, for HEAT mode the range is 10.0 or 
16.0-30.0°C.
Even if you set to 10.0, 16.0, or HEAT mode 17.0°C, if you run the 
product on AUTO, COOL, or DRY, it will run at 18.0°C.

NOTES:

 Operations modes other than the temperature setting will be the 

same at the last time operation was stopped, so Cooling 

 Heating 

 Cooling 

 Heating type of operations cannot be automatically 

set.

 If you set the ON timer and OFF timer on the same time, the air 

conditioner will run the ON timer. If two ON timer are set at the 
same time, the air conditioner will run in the order of the program 
number.

 If there is a power interruption, such as due to a power outage 

during the WEEKLY timer setting or a circuit breaker cutting out, 
the internal timer of the air-conditioning will be incorrect. (See page 
9 "Auto-restart function".) In such a case, the main timer lamp will 
notify you of this by 

fl

 ashing, so carry out matching of the time and 

date. (See page 2 "remote controller preparation".)

 You cannot use the WEEKLY timer together with the other timers.

If you want to run the product on WEEKLY timer after using the 
ON/OFF timer, Program timer, or SLEEP timer while the WEEKLY 
timer is running, you need to activate the WEEKLY timer again.

To set the WEEKLY timer, 

fi

 rst follow steps 

~

 on page 6 for 

the ON/OFF timer.

4

  Select the program number and the day using the SELECT 

button.

Program  1Week Program  Monday Program  Tuesday

Program  Sunday

Program  1Week Program  Monday

Program  Saturday Program  Sunday

 

Press the NEXT button, when the program number and day you 
want to set are 

fl

 ashing.

5

  Using the SELECT button select the operation mode (ON timer, 

OFF timer, or without a timer).

To operate without a timer

1.   Press the NEXT button to go back to step 4

 

and con

fi

 gure the 

next setting.

2.  Press the SEND button to 

fi

 nish

 

Press the NEXT button.

6

  Press the SELECT button  to set the desired ON time or OFF 

time.

If you selected OFF in step 5

1.   Press the NEXT button to go back to step 4 and con

fi

 gure the 

next setting.

2.  Press the SEND button.

 

Press the NEXT button.

7

  Press the SELECT button to set the temperature.

If you want to move on to the next setting, press the NEXT button, 
return to step 4 and con

fi

 gure the next setting.

8

  To complete the setting, press the SEND button.

If you want to cancel the setting midway, please press the 
TIMER SETTING button instead of pressing the SEND button.

NOTES:

  When canceling the WEEKLY timer, select without a timer in Step 5 

in the WEEKLY timer setting.

  If you want to go back to the previous step when con

fi

 guring 

settings, press the BACK button to return to the previous step.

  Press the SEND button, when you are close to the main unit. If you 

do so when far from the main unit, the signal may not get properly 
sent, and the settings may not get properly con

fi

 gured.

  To check the schedule, repeat steps 1 to 3 to enter the WEEKLY 

timer mode, then use the SELECT button to browse through the 
WEEKLY timer settings in the order shown in step 4.

  To cancel the WEEKLY timer, press the WEEKLY button while the 

WEEKLY indicator is on. (Erases the indicator)

9320455040-02_OM_EN.indd   7

9320455040-02_OM_EN.indd   7

12/1/2017   11:01:10 AM

12/1/2017   11:01:10 AM

Содержание ASTG18KMCB

Страница 1: ...ep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and refrain from touching the product or the power source to prevent any electrical hazards The appliance shall be stored in a room without continuously operating ignition sources for example open...

Страница 2: ...se items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or cov...

Страница 3: ... may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 8 8 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow directi...

Страница 4: ...is not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up the...

Страница 5: ...s shown in this figure RESET 18 TEST RUN button Only used for the initial test in the unit installation Do not press this button under normal use because it will cause incorrect operation During the test run the OPERATION indicator and the TIMER indicator blink simultaneously To quit the test run that is started unintentionally you need to turn off the air conditioner by pressing the START STOP bu...

Страница 6: ... C 4 C 2 C 1 C In COOL or DRY mode continued Remote controller custom code setting When two or more air conditioners are installed in a room and the remote controller is operating an air conditioner other than the one you wish to set change the custom code of the remote controller to operate only the air conditioner you wish to set 4 selections possible When two or more air conditioners are instal...

Страница 7: ...se the WEEKLY timer together with the other timers If you want to run the product on WEEKLY timer after using the ON OFF timer Program timer or SLEEP timer while the WEEKLY timer is running you need to activate the WEEKLY timer again To set the WEEKLY timer first follow steps on page 6 for the ON OFF timer 4 Select the program number and the day using the SELECT button Program 1Week Program Monday...

Страница 8: ...ch as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to the ...

Страница 9: ...s Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat from ...

Страница 10: ...it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the ...

Страница 11: ...ng absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as follows 1 Remove the filter 2 Flush the filter with high pressure hot water until the surface of the filter is covered with water 3 Wash the filter gently with diluent neutral detergent Do not wash it by wringing ...

Страница 12: ... adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Outdoor unit emits water During heating operation the outdoor unit...

Отзывы: