background image

En-4

OPERATING MANUAL

 

CAUTION

• To prevent malfunction or damage of the remote controller:

 

- Place remote controller at where will not be exposed to 

direct sunlight or excessive heat.

 

- Remove batteries if the product is not going to be used for 

an extended period.

 

- Exhausted batteries must be removed immediately, and 

be disposed according to the local laws and regulations of 
your region.

• If leaking battery 

À

 uid comes in contact with your skin, eyes, 

or mouth, immediately rinse with plenty of clean water, and 
consult your physician.

• Obstacles such as a curtain or wall between the remote 

controller and the indoor unit may affect the appropriate 
signal transmission.

• Do not apply strong shocks to the remote controller.

• Do not pour water on the remote controller.

Remote Controller Overview and Operations

3

1

5

6

7

4

23

20

21

19

18

2

22

24

11

16

15

8

9

10

13

12

14

17

You can quickly start operation with the following 3 steps:

1 Start/Stop 

button

2 MODE 

button

Switches operation mode in following order.

AUTO  

COOL  

DRY  

FAN

3  

TEMP. (temperature) buttons

Sets the desired temperature. 
In COOL or DRY mode, the temperature needs to be set lower than 
the current room temperature.
Otherwise, corresponding operation mode may not start.

Temperature setting range

AUTO/COOL/DRY

18.0–30.0 °C

Notes: 

Temperature control is not available in FAN mode.

 

Remote controller display

In this section, all the possible indicators are displayed for description. 
In actual operation, the display is linked with the button operation, and 
only shows the necessary indicators for each setting.

5 POWERFUL 

button

Activates the POWERFUL operation. 
The unit will operate at maximum power and strong air

À

 ow to quickly 

cool down the room.
When activated, the indoor unit will emit 3 short beeps.
To turn off, press the POWERFUL button again. The indoor unit will 
then emit 2 short beeps.

POWERFUL operation is automatically turned off in the following 
situations:
• Adjusted room temperature reaches the set temperature in COOL, 

DRY mode.

• 20 minutes have passed after the POWERFUL operation mode has 

been set.

Even in situations above, the POWERFUL operation will not 
automatically turn off unless it has run for a certain amount of time.

Notes:

• The air

À

 ow direction and the fan speed are controlled automatically.

• This operation cannot be performed simultaneously with ECONOMY 

operation.

• POWERFUL operation will override the OUTDOOR UNIT LOW 

NOISE, ENERGY SAVING functions. Both functions, if set, will start 
after the POWERFUL operation is turned off.

6 ECONOMY 

button

• Starts or stops ECONOMY operation that saves more electricity 

than other operation modes by changing the set temperature to a 
moderate setting.

• By pressing the ECONOMY button, the ECONOMY indicator on the 

indoor unit turns on.

• In COOL or DRY mode, the room temperature will be adjusted a few 

degrees higher than the set temperature. 

Notes:

• In COOL or DRY mode, the maximum output of this operation is 

approximately 70 % of usual air conditioning operation.

• This operation cannot be performed during temperature monitoring 

by AUTO mode.

(continued)

9320455088_OM_EN.indd   4

3/23/2017   1:55:03 PM

Содержание ASTG18CMCB

Страница 1: ...y authorized service personnel In the event of refrigerant leakage be sure to keep away from re or any Àammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and refrain from touching the product or the power source to prevent any electrical hazards The appliance shall be stor...

Страница 2: ...is may cause quality deterioration of those items Do not expose animals or plants to the direct airÀow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum ns of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airÀow at replaces or he...

Страница 3: ...t to position 5 8 for more than 30 minutes in COOL or DRY mode the louver will automatically return to position 4 Keeping the position 5 8 during COOL or DRY mode may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airÀow direction louver the angle of the power diffuser moves as follows Vertical airÀow direction louver...

Страница 4: ...ption In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airÀow to quickly cool down the room When activated the indoor unit will emit 3 short beeps To turn off press the POWERFUL button again The indoor unit will then emit 2...

Страница 5: ...o fall asleep comfortably with gradual temperature control See page 6 14 ON OFF timer button Activates the ON OFF timer 15 NEXT button Used for adjusting the timer setting 16 BACK button Used for adjusting the timer setting 17 RESET button When you press the RESET button press it gently by using the tip of a ballpoint pen or other small object in correct direction as shown in this gure RESET 18 TE...

Страница 6: ...e set time has elapsed Set temperature Set time 1 hour 2 C 1 C In COOL or DRY mode continued Remote controller custom code setting When two or more air conditioners are installed in a room and the remote controller is operating an air conditioner other than the one you wish to set change the custom code of the remote controller to operate only the air conditioner you wish to set 4 selections possi...

Страница 7: ... timers If you want to run the product on WEEKLY timer after using the ON OFF timer Program timer or SLEEP timer while the WEEKLY timer is running you need to activate the WEEKLY timer again To set the WEEKLY timer rst follow steps on page 6 for the ON OFF timer 4 Select the program number and the day using the SELECT button Program 1Week Program Monday Program Tuesday Program Sunday Program 1Week...

Страница 8: ...s or electric appli ances such as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air condi...

Страница 9: ... of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Temperature and Humidity Range Permissible ranges of temperature and humidity are as follows COOL DRY Indoor temperature About 18 C to 32 C Indoor humidity Below approximatel...

Страница 10: ...top of the panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performance and may c...

Страница 11: ...is left with the package opened Replace the lter once every 3 months under normal use By setting the fan speed high the air cleaning effect increases Ion deodorization lter UTR FA16 2 Light blue 1 sheet The lter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra ne particle ceramic To maintain the deodorizing effect clean the...

Страница 12: ...ode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Before you call for or request servicing troubleshoot a problem by performing following checks Symptom Diagnostic See page Does not operate at all Has the circuit breaker been turned off Has there been a power outage Has a fuse ...

Отзывы: