En-4

4.5.  Temperature Set Back timer

The Temperature Set Back timer changes the temperature setting for 
day of the week.
The temperature setting range is the same as the range of the operation 
mode.

Set Back temperature

ON 

Normal temperature

28 °C

24 °C

24 °C

OFF

NOTES:

•  The Temperature Set Back timer only changes the set temperature, 

it cannot be used to start or stop air conditioner operation.

•  The Temperature Set Back timer can be set to operate up to 2 times 

per day but only 1 temperature setting can be used.

•  The Temperature Set Back timer can be used together with the On, 

Off , and Weekly timer.

5.  ENERGY SAVING OPERATIONS

5.1.  Economy operation

It saves more electricity than other operation modes by changing the set 
temperature to a moderate setting.

Operation 

mode

Setting details

Cooling/Dry

The room temperature will be few degrees higher than 
the set temperature

Heating

The room temperature will be few degrees lower than 
the set temperature

NOTES:

•  In the Cooling, Heating, or Dry mode, the maximum output of this 

operation is approximately 70 % of usual operation. If the room is 
not cooled or heated well during the Economy operation, select 
normal operation.

•  This operation cannot be performed during the temperature 

monitoring by the Auto mode.

•  In case of multi-type air conditioner, the Economy operation mode is 

only available for the set indoor unit.

5.2.  Fan control for energy saving

In the Cooling or Dry operation, when the room temperature reaches the 
set temperature, the indoor unit fan rotates intermittently to save power. 
This function is activated at the time of purchase.
To deactivate this function, refer to the operation manual of the remote 
controller.
Even if the setting is changed, if the fan speed is set to Auto in Cooling 
or Dry mode, this function still works to suppress the diff usion of 
circulated indoor humidity.

6.  OTHER OPERATIONS

6.1.  10 °C Heat operation

NOTES: 

•  This function is available only by wireless remote controller.
•  In simultaneous multi connection, this function by using the wireless 

remote controller cannot be used.

10 °C Heat operation maintains the room temperature at 10 °C 

so as to prevent the room temperature to drop too low.

NOTES:

•  When the room temperature is warm enough, This operation will not 

be performed.

•  In case of multi-type air conditioner, if other indoor unit is used 

for heating, the temperature of the room where the 10 °C Heat 
operation is applied will rise. When using the 10 °C Heat operation, 
we recommend all indoor units should be run under the 10 °C Heat 
operation.

7.  CLEANING AND CARE

 

CAUTION

•  Before cleaning the indoor unit, be sure to turn it off  

and disconnect all the power supply.

•  The fan operates at high speed inside the unit, and 

could result in personal injury.

•  If the fi lter cleaning involves high-place work, please 

consult the professional technical service

 

personnel.

•  Do not expose the indoor unit to liquid insecticides or 

hair sprays.

When cleaning the unit, do not use water hotter than 40 °C, 

harsh abrasive cleansers, or volatile agents like benzene or 

thinner.

 Cleaning air fi lter

●   Remove the dust from the air fi lters by vacuuming or washing 

them. After washing, allow the air fi lters to dry thoroughly in an area 
protected from sunlight.

●   Dust can be cleaned from the air fi lter either with a vacuum cleaner, 

or by washing the fi lter in a solution of mild detergent and warm water. 
If you wash the fi lter, be sure to allow it to dry thoroughly in a shady 
place before reinstalling.

●   If dirt is allowed to accumulate on the air fi lter, airfl ow will be reduced, 

lowering operating effi  ciency and increasing noise.

After extended non-use of the unit

If you do not use this product for 1 month or more, perform the Fan 
mode operation for half a day to dry the internal parts thoroughly before 
you perform normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the product performance even if you have maintained the unit 
with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.

9383813009_OM.indb   4

9383813009_OM.indb   4

12/12/2018   9:03:03 AM

12/12/2018   9:03:03 AM

Содержание ARXG12-54KHTAP

Страница 1: ...ΣΤΙΚΟ Τύπος αγωγού Προτού χρησιμοποιήσετε το προϊόν διαβάστε προσεκτικά τις παρούσες οδηγίες και φυλάξτε το παρόν εγχειρίδιο ώστε να μπορείτε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo conduta Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Канального типа...

Страница 2: ...lways consult authorized service personnel for repairing installation and relocation of this product Improper installation or handling will cause leakage electric shock or fire In the event of a malfunction such as burning smell immediately stop operation of the air conditioner and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug Then consult auth...

Страница 3: ...aces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product CAUTION Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your pr...

Страница 4: ...an the current room temperature otherwise the fan alone will operate The indoor unit fan may stop from time to time because of the Fan control for energy saving refer to page 4 Dry mode Use for gently cooling while dehumidifying your room NOTES You cannot heat the room Set the temperature lower than the current room temperature otherwise the operation will not operate The unit will operate at low ...

Страница 5: ...n by using the wireless remote controller cannot be used 10 C Heat operation maintains the room temperature at 10 C so as to prevent the room temperature to drop too low NOTES When the room temperature is warm enough This operation will not be performed In case of multi type air conditioner if other indoor unit is used for heating the temperature of the room where the 10 C Heat operation is applie...

Страница 6: ...tructions on how to operate please refer to the operating manual of the remote controller 8 GENERAL INFORMATION Inverter On start up the air conditioner will operate at maximum capacity to bring the room quickly down to desired temperature Once the temperature in the room begins to achieve the set temperature the air conditioner will reduce its capacity and energy usage to the minimum capacity and...

Страница 7: ...ectable indoor units and connectable type of the separation tube vary by model Depending on model this function cannot be used For details please consult authorized service personnel In simultaneous multi connection all indoor units can be operated simultaneously from one remote controller connected to the primary indoor unit For this unique characteristic of the simultaneous multi connection the ...

Страница 8: ...mode Do you hear a sizzling sound This sound is produced by the Automatic defrosting operation Refer to page 5 Smell coming from the unit The air conditioner may absorb various smells generated from interior textile furniture or cigarette smoke These smells may be emitted during the operation Mist or steam is emitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensa...

Отзывы: