background image

13

HEAT & COOL MODEL (Reverse Cycle)

Auto changeover function

l

  When AUTO CHANGEOVER is selected, the air conditioner 

selects the appropriate operation mode (Cooling or Heat-
ing) according to your room’s present temperature.

l

  When AUTO CHANGEOVER is fi rst selected, the fan will 

operate at very low speed for about 2 minute while the 
unit determines the current conditions of the room and 
selects the proper operation mode.

  If the difference between thermostat setting and actual 

room temperature is more than +2 °C

 

 Cooling operation

   

(Monitor operation may be selected if the outdoor 
temperature is low.)

  If the difference between thermostat setting and actual 

room temperature is within ±2 °C 

 

 Monitor operation

  If the difference between thermostat setting and actual 

room temperature is more than –2 °C 

 

 Heating operation

   

(Monitor operation may be selected if the outdoor 
temperature is high.)

OPERATING TIPS

Mode operation: AUTO

About Mode Operation

During Heating mode:

Set the thermostat to a temperature set-
ting that is higher than the current room 
temperature. The Heating mode will not 
operate if the thermostat is set lower than 
the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room 
temperature. The Cooling and Dry modes 
will not operate if the thermostat is set 
higher than the actual room temperature 
(in Cooling mode, the fan alone will ope-
rate).

During Fan mode:

You can not use the unit to heat and cool 
your room.

*Heating:

l

  Use to warm your room.

 

l

  When Heating mode is selected, the air conditioner will operate at very 

low fan speed for about 3 to 5 minutes, after which it will switch to the 
selected fan setting. This period of time is provided to allow the indoor 
unit to warm up before beginning full operation.

 

l

  When the room temperature is very low, frost may form on the outside 

unit, and its performance may be reduced. In order to remove such 
frost, the unit will automatically enter the defrost cycle from time to 
time. During Automatic Defrosting operation, the heat operation will 
be interrupted.

 

l

  After the start of heating operation, it takes sometime before the room 

gets warmer.

Cooling:

 

l

  Use to cool your room.

Dry:

 

l

  Use for gently cooling while dehumidifying your room.

 

l

  You cannot heat the room during Dry mode.

 

l

  During Dry mode, the unit will operate at low speed; in order to adjust 

room humidity, the indoor unit’s fan may stop from time to time.

 

  Also, the fan may operate at very low speed when adjusting room 

humidity.

 

l

  The fan speed cannot be changed manually when Dry mode has been 

selected.

Fan:

 

l

  Use to circulate the air throughout your room.

COOLING MODEL

l

  When the room temperature is 2 °C higher than the set 

temperature, the mode will switch between Cooling and 
Drying. 

l

  During the Drying mode operation, the FAN setting should 

be switched to LOW for a gently cooling effect during 
which the fan may temporarily stop rotating. 

l

  When the room temperature is near the thermostat set-

ting, the air conditioner will begin monitor operation. 
In the monitor operation mode, the fan will operate at 
very low speed. If the room temperature subsequently 
changes, the air conditioner will once again select the 
appropriate operation (Heating or Cooling) to adjust 
the temperature to the value set in the thermostat. (The 
monitor operation range is ±2 °C relative to the thermostat 
setting.)

l

  Should the power supply to the air conditioner be inter-

rupted by a power failure, the air conditioner will restart 
automatically in the previously selected mode once the 
power is restored.

l

  Use of other electrical appliances (electric shaver, etc.) or 

nearby use of a wireless radio transmitter may cause the 
air conditioner to malfunction. In this event, temporarily 
disconnect the power supply, reconnect it, and then use 
the remote controller to resume operation.

AUTO Restart

In Event of Power Interruption

9374379385.indd   Sec1:13

9374379385.indd   Sec1:13

11/3/09   8:48:35 AM

11/3/09   8:48:35 AM

Содержание ARTC72L

Страница 1: ...ERATING MANUAL Air Conditioner DUCT TYPE High Static 3 Phase ARTC72L ARTC90L H H Air Conditioning PO Box 4316 EIGHT MILE PLAINS QLD 4113 Ph 07 3276 1800 Fax 07 3276 1900 sales hhaircon com au www hhaircon com au ...

Страница 2: ......

Страница 3: ...ntains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product 9374379385 indd 1 9374379385 indd 1 11 3 09 8 48 25 AM 11 3 09 8 48 25 AM ...

Страница 4: ...lace animals or plants in the direct path of the air flow l When restarting after a long period of disuse in the winter turn the power switch on at least 6 hours before starting the unit l Do not drink the water drained from the air conditioner l Do not use in applications involving the storage of foods plants or animals precision equipment or art works l Do not apply any heavy pressure to radiato...

Страница 5: ...l Airflow Direction and Swing Button 1 Horizontal Airflow Direction and Swing Button 2 FILTER RESET Button 3 Operation Lamp Timer and Clock Display Operation Mode Display Fan Speed Display Operation Lock Display Temperature Display Function Display Defrost Display Thermo Sensor Display Economy Display 1 3 These functions cannot be used o i u p a t 1 e 5 r q 0 3 4 w 8 6 2 y 9 7 9374379385 indd Sec1...

Страница 6: ...ons to set the current time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK Set the current day and time 9374379385 ind...

Страница 7: ... AUTO Press the SET TEMP buttons to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY OPERA TION For details on the function refer to page 12 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle To start stop operation To set the operation mode l Operation mode setting l Room temperature setting l F...

Страница 8: ...mperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is locked at the factory In order to detect the room temperature correctly consult authorized service personnel when using this function If this function is locked the location where the room temperature...

Страница 9: ... be used to repeat the timer settings for all of the days Temperature SET BACK timer See page 9 Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings ON OFF TIMER Press the TIMER MODE button to select the ON timer or OFF timer 2 Press the TIMER DELETE button to cancel the timer mode The timer mo...

Страница 10: ...r day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more l To delete the operating time If the TIMER DELETE button is pressed during steps 3 or 4 the operating time for the selected day will be deleted...

Страница 11: ...cel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below l Normal l Next day setting Setting day Preceding day Next day Setting day Preceding day Nex...

Страница 12: ... 15 18 21 ex When setting all days together l Temperature setting Press the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings ON OFF 24 C 24 C 28 C SET BACK temperature Normal te...

Страница 13: ...CAUTION WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker to ensure that power is completely off Before requesting service perform the foll...

Страница 14: ...to time Also the fan may operate at very low speed when adjusting room humidity l In the monitor AUTO operation the fan will operate at very low speed Water is produced from the outdoor unit l During Heating operation water may be produced from the out door unit due to the Automatic Defrosting operation 12 thermo sensor display on the remote controller is flashing l The room temperature sensor may...

Страница 15: ...ferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance l Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may b...

Страница 16: ...mance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the heat operation will be interrupted l After the start of heating operation it takes sometime before the room gets warmer Cooling l Use to cool your room Dry l Use for gently cooling while dehumidifying your room l You cannot heat the room...

Страница 17: ...he automatic protection circuit may operate interrupting the operation If the unit is used under lower temperature conditions than those noted here the heat exchanger may freeze causing water leakage or other malfunction l Do not use the air conditioner for any purpose other than room cooling dry room heating or fan SELF DIAGNOSIS SU MO TU WE TH FR SA When EE in Temperature Display is displayed in...

Страница 18: ...FUJITSU GENERAL LIMITED 1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan 9374379385 indd Sec1 15 9374379385 indd Sec1 15 11 3 09 8 48 35 AM 11 3 09 8 48 35 AM ...

Отзывы: