7

WEEKLY TIMER

● 

To start

CLOCK ADJUST

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

3 6 9 12 15 18 21

When the weekly timer is selected, the
timer starts automatically.

The operating time for the current
day is displayed.

ex. Operating time 7:00-18:00

● 

To cancel

Press the DELETE button to cancel
the timer mode.

The timer mode can also be
canceled by changing the timer
mode using the timer mode button.

To set the DAY OFF (for a holiday)

1

During the weekly timer,
press the SET button for 2
seconds or more to set the
day.

SET

Select the day to set the DAY
OFF.

Press the DAY (DAY OFF)
button for 2 seconds or
more to set the DAY OFF.

Press the SET button for 2
seconds or more to com-
plete the DAY OFF setting.

2

4

DAY OFF

DAY

SET

3

DAY OFF

DAY

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

To cancel

Follow the same procedures as

those for setup.

ex. The DAY OFF is set for Monday.

NOTES

The DAY OFF setting is only available for days for which weekly settings already exist.

If the operating time carries over to the next day (during a next day setting), the effective DAY OFF range will be set as
shown below.

● 

Normal

● 

Next day setting

Setting day

Preceding day

 Next day

Setting day

Preceding day

 Next day

The DAY OFF setting can only be set one time. The DAY OFF setting is canceled automatically after the set day has
passed.

 mark: Indicates the DAY OFF

ON

OFF

ON

OFF

DAY OFF

WEEKLY

WEEKLY

WEEKLY

WEEKLY

ON

OFF

ON

OFF

DAY OFF

DELETE

WEEKLY timer operation

9365350034_P1-P15

4/25/05, 1:48 PM

7

Содержание ART90 Series

Страница 1: ...OPERATING MANUAL ART90 Series AIR CONDITIONER DUCTTYPE SU MO TU WE TH FR SA AM PM 3 6 9 12 15 18 21 KEEPTHIS OPERATION MANUAL FOR FUTURE REFERENCE P N9365350034 9365350034_Cover 4 25 05 1 47 PM 1 ...

Страница 2: ...onditioner directly to water Do not operate the air conditioner with wet hands Turn off power source when not using the unit for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter Connection valves become hot during heating handle with care Check the condition of the installation stand for damage Do not place animals or plants i...

Страница 3: ...O SENSOR SET BACK DAY CLOCK ADJUST SU MO TU WE TH FR SA 3 6 9 12 15 18 21 SET Button Operation Lamp Timer and Clock Display Operation Mode Display Fan Speed Display Operation Lock Display Temperature Display Function Display Defrost Display Thermo Sensor Display Energy Save Display Fig 1 Indoor Unit Air intake Air outlet Air intake Outlet port Intake port Drain pipe Main Drain pipe safety Install ...

Страница 4: ... current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday 10 00 Press again to end CLOCK ADJUST SU MO TU WE TH FR SA 1 3 4 AUTO COOL DRY HEAT FAN Lower Raise Temperature setting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 16 to 30 C Operation lamp Air conditioner ON Lit brightly Air conditioner OFF Not lit Press the start stop button Press ...

Страница 5: ...he mark appears If any button is pressed during the child lock the CL display flashes Room temperature sensor selection Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is locked at the factor...

Страница 6: ...ed to repeat the timer settings for all of the days Temperature SET BACK timer See page 8 Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings ON OFFTIMER Press the timer mode button to se lect the ON timer or OFF timer 2 Press the DELETE button to cancel the timer mode The timer mode can also ...

Страница 7: ...OFF times can be set per day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the SET button for 2 seconds or more SET To delete the operating time DELETE If the DELETE button is pressed during steps 3 or 4 the operating time for the selected...

Страница 8: ...ds or more to com plete the DAY OFF setting 2 4 DAY OFF DAY SET 3 DAY OFF DAY SU MO TU WE TH FR SA 3 6 9 12 15 18 21 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a ne...

Страница 9: ...4 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 ex When setting all days together Temperature setting Press the set temperature buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the SET button for 2 sec onds or more to complete the temperature SET BACK timer settings SET ON OFF 24 C 24 C ...

Страница 10: ...Energy save The energy conservation mode ENERGY SAVE raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit If you press the ENERGY SAVE button while the unit is in the timer mode the unit will go into the conservation mode when the unit starts with the timer If you turn off the air conditioner wh...

Страница 11: ...to remove dust and dirt from the air filter or wash in a synthetic detergent After washing dry in a shaded place then reinstall When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel When cleaning the unit s body ...

Страница 12: ...ting operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation starts the fan stops temporarily to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the indoor and the outdoor unit will stop If you wish to warm the room further set the th...

Страница 13: ...ells stop operation immediately turn off the electrical breaker and consult with authorized service personnel TROUBLESHOOTING TEMPERATURE AND HUMIDITY RANGE Outdoor temperature About 0 to 46 C Indoor temperature About 18 C to 30 C Indoor humidity Below approximately 80 If the air conditioner is used continuously for many hours water may condense on the surface and drip Outdoor temperature About 10...

Страница 14: ... 9365350034_P1 P15 4 25 05 1 48 PM 13 ...

Страница 15: ...9365350034_P1 P15 4 25 05 1 48 PM 14 ...

Страница 16: ...9365350034_P1 P15 4 25 05 1 48 PM 15 ...