background image

En-16

TROUBLESHOOTING

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

The AIR CLEAN Indicator
Lamp (green) will begin
to slowly flash (as shown
in the figure):

The AIR CLEAN Indicator
Lamp (green) will begin
to flash quickly (as shown
in the figure):

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the Power Supply Plug is disconnected and then re-
connected to a power outlet, the protection circuit will operate for
about 3 minutes, preventing unit operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

During Heating operation, a sizzling sound may be heard occasional.
This sound is produced by the Automatic Defrosting operation.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
Indicator Lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

During SUPER QUIET operation, the fan will operate at very low
speed.

In the monitor AUTO operation, the fan will operate at very low
speed.

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

After approximately 400 hours of Air Cleaning Mode use, the AIR
CLEAN Indicator Lamp will begin to flash slowly (as shown in the
figure). When this occurs, please stop the system, remove the
mains socket and carry out maintenance on the dust collecting
unit's air filter.

After approximately 500 hours of Air Cleaning Mode use, the AIR
CLEAN Indicator Lamp will begin to flash quickly (as shown in
the figure). At this point, Air Cleaning will stop functioning. Please
stop the system, remove the mains socket and carry out mainte-
nance on the dust collecting unit's air filter.

See Page

17

17

17

5

5

5

17

13-14

13-14

NORMAL

FUNCTION

In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the
Power Supply Plug, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to disconnect the Power Supply Plug or turn off your circuit breaker to
ensure that power is completely off.

Before requesting service, perform the following checks:

Содержание AOYS09LDC

Страница 1: ...iano EλληvIkά OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ P N9314987014 03 ROOM AIR CONDITIONER WALL MOUNTED TYPE HEAT COOL MODEL REVERSE CYCLE Português Русский ...

Страница 2: ...specified cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do...

Страница 3: ...thermostat setting is gradually raised during the period of operation When the set time is reached the unit automati cally turns off WIRELESS REMOTE CONTROLLER The Wireless Remote Controller allows convenient control of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE OPE...

Страница 4: ... 5 Outdoor Unit G Intake Port H Outlet Port I Pipe Unit J Drain port bottom NAME OF PARTS Refer to the folded out page on the cover Fig 6 Remote Controller K Signal Transmitter L MASTER CONTROL button M FAN CONTROL button N START STOP button O AIR CLEAN button P COIL DRY button Q SET button R SET TEMP button S SLEEP button T SWING button U TIMER MODE button V TIMER SET buttons W TEST RUN button Th...

Страница 5: ...slide the battery compartment lid on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 X Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 ...

Страница 6: ... FAN CONTROL button Fig 6 M Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room ...

Страница 7: ...low the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERATION Indica tor Lamp red Fig 3 5 will flash and the heat operation will be inter rupte...

Страница 8: ...he operation install the intake filter and then use the START STOP button to restart the operation Use the FAN CONTROL button to change the fan speed Refer to page 5 The plasma filter unit operates most effectively at the highest fan speed The AIR CLEAN Indicator Lamp green will flash to inform you that the periodic cleaning of the plasma filter unit is required Refer to page 13 14 AIR CLEANING OP...

Страница 9: ...nds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation...

Страница 10: ...g Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically rai...

Страница 11: ...tton Horizontal right left air flow direction is adjusted manually by moving the Air Flow Direction Louvers Whenever making horizontal airflow adjustments start air conditioner operation and be sure that the vertical air direction louvers are stopped Vertical Air Direction Adjustment Press the SET button Fig 6 Q Each time the button is pressed the air direction range will change as follows 1 2 3 4...

Страница 12: ...Lamp orange Fig 3 8 and the COIL DRY Display Fig 7 c will light Then it will disappear after 30 minutes To cancel COIL DRY Operation Press the START STOP button Fig 6 N during COIL DRY Operation The COIL DRY Indicator Lamp orange Fig 3 8 and the COIL DRY Display Fig 7 c will go out Then the operation stops About COIL DRY Operation Press the COIL DRY button again during COIL DRY Operation COIL DRY ...

Страница 13: ...close the Intake Grille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of m...

Страница 14: ...o 45 C for 10 to 15 minutes If the plasma filter unit is ex tremely dirty extremely dilute a mild synthetic laun dry detergent low alkalinity or isotope detergent to 15 times the standard concentration and allow the plasma filter unit to soak in it 2 Gently move up and down and to the right and left A soft sponge can also be used to wipe the surface 3 Rinse with clean water 4 Shake the plasma filt...

Страница 15: ...nts the two ends of its lower side as well as two center points of the lower side as shown in the figure to close it If after cleaning the dust collection unit the operation indicator lamp and the timer indicator lamp flash during Air Cleaning please ensure that the unit is not damp and that the intake grille is properly closed If after having checked that the unit is fully dry and that the intake...

Страница 16: ...aned once every six months Please only install filters that are licensed by our company Regarding storage and care of the filter please avoid exposing it to high temperatures and high humidity Also use it as soon as possible after opening its packaging Hook Filter case Filter Case Hook Hook Hook Click When removing the filter please follow these steps backwards How to install or remove the Air cle...

Страница 17: ...operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the thermostat for a higher setting During Heating operation the unit will temporarily stop opera tion ...

Страница 18: ...g performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating...

Страница 19: ...e Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 80 or more Acoustic Noise Information The maximum sound pressure level is less than 70 dB ...

Страница 20: ......

Отзывы: