ou use a wireless remote control, the lamp
he photo detector unit will output error codes
way of blinking patterns.
ou use a wired type remote control, error
es will appear on the remote control display.
the lamp blinking patterns and error codes
e table. An error display is displayed only
ng running.
DOOR UNIT
d WIRED REMOTE CONTROL
R R O R D E T E C T I O N
( )
( )
(1)
(2)
Wired remote control
communication error
(1)
(5)
Check run unfinished
(2)
(1)
Unit number or Refrigerant circuit
address setting error
[Simultaneous Multi]
(2)
(2)
Indoor unit capacity error
(2)
(3)
Combination error
(2)
(4)
Connection unit number
•
error (indoor slave unit)
[Simultaneous Multi]
Connection unit number error
•
(indoor unit or branch unit)
[Flexible Multi]
(2)
(7)
Master unit, slave unit set-up
error [Simultaneous Multi]
(3)
(2)
Indoor unit PCB model
information error
(3)
(5)
Manual auto switch error
(4)
(1)
Inlet air temp. sensor error
(4)
(2)
Indoor unit Heat Ex. Middle
temp. sensor error
(5)
(1)
Indoor unit fan motor error
(5)
(3)
Drain pump error
(5)
(7)
Damper error
(5)
(15)
Indoor unit error
(6)
(2)
Outdoor unit main PCB model
information error or
communication error
(6)
(3)
Inverter error
(6)
(4)
Active filter error, PFC circuit error
(6)
(5)
Trip terminal L error
(6)
(10)
Display PCB microcomputers
communication error
(7)
(1)
Discharge temp. sensor error
(7)
(2)
Compressor temp. sensor error
(7)
(3)
Outdoor unit Heat Ex. liquid
temp. sensor error
(7)
(4)
Outdoor temp. sensor error
(7)
(5)
Suction Gas temp. sensor error
(7)
(6)
2-way valve temp. sensor error
•
3-way valve temp. sensor error
•
(7)
(7)
Heat sink temp. sensor error
(8)
(2)
Sub-cool Heat Ex. gas inlet
•
temp. sensor error
Sub-cool Heat Ex. gas outlet
•
temp. sensor error
(8)
(3)
Liquid pipe temp. sensor error
(8)
(4)
Current sensor error
(8)
(6)
Discharge pressure sensor
•
error
Suction pressure sensor error
•
High pressure switch error
•
(9)
(4)
Trip detection
(9)
(5)
Compressor rotor position
detection error (permanent stop)
(9)
(7)
Outdoor unit fan motor error
(9)
(9)
4-way valve error
(10)
(1)
Discharge temp. error
(10)
(3)
Compressor temp. error
Hi h
: 0.1s on / 0.1s off
( ) : Number of flashing
ubleshooting with the wired remote control.