Fujitsu aoyg18lac2 Скачать руководство пользователя страница 3

En-2

Special tools for R410A

2. 2. 

Tool name

Contents of change

Gauge manifold

Pressure is high and cannot be measured with a conventional 
gauge. To prevent erroneous mixing of other refrigerants, the 
diameter of each port has been changed.
It is recommended the gauge with seals –0.1 to 5.3 MPa 
(-1 to 53 bar) for high pressure. –0.1 to 3.8 MPa (-1 to 38 bar) 
for low pressure.

Charge hose

To increase pressure resistance, the hose material and base 
size were changed.

Vacuum pump

A conventional vacuum pump can be used by installing a 
vacuum pump adapter.

Gas leakage 
detector

Special gas leakage detector for HFC refrigerant R410A.

Copper pipes
It is necessary to use seamless copper pipes and it is desirable that the amount of residual 
oil is less than 40 mg/10 m. Do not use copper pipes having a collapsed, deformed or 
discolored portion (especially on the interior surface). Otherwise, the expansion valve or 
capillary tube may become blocked with contaminants.
As an air conditioner using R410A incurs pressure higher than when using conventional 
refrigerant, it is necessary to choose adequate materials. 
Thicknesses of copper pipes used with R410A are as shown in the table. Never use copper 
pipes thinner than that in the table even when it is available on the market.
Thicknesses of Annealed Copper Pipes (R410A)

Pipe outside diameter

Thickness

6.35 mm (1/4 in.)

0.80 mm

9.52 mm (3/8 in.)

0.80 mm

12.70 mm (1/2 in.)

0.80 mm

15.88 mm (5/8 in.)

1.00 mm

19.05 mm (3/4 in.)

1.20 mm

Accessories

2. 3. 

 WARNING

For installation purposes, be sure to use the parts supplied by the manufacturer or other 
prescribed parts. The use of non-prescribed parts can cause serious accidents such as 
the unit falling, water leakage, electric shock, or 

fi

 re.

Do not throw away the connecting parts until the installation has been complete.

Name and shape

Q’ty

Description

Installation Manual

1

This manual

Drain pipe

1

For outdoor unit drain piping work 
[Heat & Cool model (Reverse cycle) 
only]

Adapter assy 
9.52 mm 

 12.7 mm

1

For use when connecting model 
14 to outdoor port A or B
[18 type only]

System con

fi

 guration

2. 4. 

Layout example for the indoor units and outdoor unit.

OUTDOOR UNIT : 18 TYPE

H1

H2

H1

a

b

Outdoor unit

Indoor unit

Unit B

7-14

Connection 
cable

Power cable

Circuit breaker

Power Source

230V~50Hz

Refrigerant 
pipe

Unit A

7-14

CONNECTABLE INDOOR UNIT CAPACITY TYPE

2. 4. 1. 

 CAUTION

The total capacity of the indoor units connected must be between 14,000 and 
24,000BTU.

Be sure to check the connecting pattern in technical manual when installed since 
connection pattern is speci

fi

 ed in it. Operation cannot be guaranteed if connected by a 

method not speci

fi

 ed in it. It can cause the fault of the product.

Please connect to both of indoor unit and outdoor unit certainly.

To install an indoor unit, refer to the installation Manual included with the indoor unit.

• 

Outdoor port

Connectable model name

A

7-12/14*1

B

7-12/14*1

*1 When connecting model 14 to the outdoor unit the included adapter is necessary.  

(For more information, refer to 4.1.3. How to use adapter.)

UNIT B ø6.35, ø9.52

UNIT A ø6.35, ø9.52

OUTDOOR UNIT : 14 TYPE

H1

H2

H1

a

b

Outdoor unit

Indoor unit

Unit B

7-12

Connection 
cable

Power cable

Circuit breaker

Power Source

230V~50Hz

Refrigerant 
pipe

Unit A

7-12

CONNECTABLE INDOOR UNIT CAPACITY TYPE

2. 4. 2. 

 CAUTION

The total capacity of the indoor units connected must be between 14,000 and 
21,000BTU.

Be sure to check the connecting pattern in technical manual when installed since 
connection pattern is speci

fi

 ed in it. Operation cannot be guaranteed if connected by a 

method not speci

fi

 ed in it. It can cause the fault of the product.

Please connect to both of indoor unit and outdoor unit certainly.

To install an indoor unit, refer to the installation Manual included with the indoor unit.

• 

Outdoor port

Connectable model name

A

7-12

B

7-12

9379342070-02_IM.indb   2

9379342070-02_IM.indb   2

2011-12-21   11:13:39

2011-12-21   11:13:39

Содержание aoyg18lac2

Страница 1: ...AZIONE ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ MANUAL DE INSTALAÇÃO РУКОВОДСТВО ПО УСТАНОВКЕ MONTAJ KILAVUZU PART NO 9379342070 02 For authorized personnel only Nur für autorisiertes Personal Pour le personnel agréé uniquement Solo para personal autorizado Ad uso esclusivo del personale autorizzato Για εξουσιοδοτημένο προσωπικό σέρβις Apenas para técnicos autorizados Для уполномоченного персонала Yetkili servis p...

Страница 2: ...ibly result in personal harm to the user or damage to property Read carefully all security information before use or install the air conditioner Do not attempt to install the air conditioner or a part of the air conditioner by yourself This unit must be installed by qualified personnel with a capacity certificate for handling refrigerant fluids Refer to regulation and laws in use on installation p...

Страница 3: ...shape Q ty Description Installation Manual 1 This manual Drain pipe 1 For outdoor unit drain piping work Heat Cool model Reverse cycle only Adapter assy 9 52 mm 12 7 mm 1 For use when connecting model 14 to outdoor port A or B 18 type only System configuration 2 4 Layout example for the indoor units and outdoor unit OUTDOOR UNIT 18 TYPE H1 H2 H1 a b Outdoor unit Indoor unit Unit B 7 14 Connection ...

Страница 4: ...t and fall off of the balcony CAUTION Do not install the outdoor unit in the following areas Area with high salt content such as at the seaside It will deteriorate metal parts causing the parts to fail or the unit to leak water Area filled with mineral oil or containing a large amount of splashed oil or steam such as a kitchen It will deteriorate plastic parts causing the parts to fail or the unit...

Страница 5: ...er do not install the unit with it tilted towards the side containing the compressor When installing the outdoor unit where it may exposed to strong wind fasten it securely Decide the mounting position with the customer as follows 1 Install the outdoor unit in a location which can withstand the weight of the unit and vibration and which can install horizontally 2 Provide the indicated space to ens...

Страница 6: ...to the necessary length with a pipe cutter 1 Hold the pipe downward so that the cuttings will not enter the pipe and remove any 2 burrs Insert the flare nut always use the flare nut attached to the indoor and outdoor units 3 respectively onto the pipe and perform the flare processing with a flare tool Leakage of refrigerant may result if other flare nuts are used Protect the pipes by pinching them...

Страница 7: ... condenser may overheat Before servicing the unit turn the power supply switch OFF Then do not touch electric parts for 5 minutes due to the risk of electric shock Make sure to perform grounding work Improper grounding work can cause electric shocks CAUTION The primary power supply capacity is for the air conditioner itself and does not include the concurrent use of other devices Do not use crosso...

Страница 8: ...acuum pump gauge manifold and charge hose for R410A exclusively Using the same vacuum for different refrigerants may damage the vacuum pump or the unit After connecting the piping check the joints for gas leakage with gas leak detector or soapy water CHECKING GAS LEAKAGE AND PURGING AIR 6 1 1 Gas leak checks are performed using either vacuum or nitrogen gas so select the proper one depending on th...

Страница 9: ...aker in accordance with the related laws and regulations and electric company standards CAUTION When the voltage is low and the air conditioner is difficult to start contact the power company the voltage raised TEST RUN 8 The test run method may be different for each indoor unit that is connected Refer to the installation Manual included with each indoor unit CAUTION Always turn on the power 12 ho...

Отзывы: