FINISHING 

8. 

 (1)  Insulate between pipes.

•  Insulate suction and discharge pipes separately.
•  For rear, right, and bottom piping, overlap the connection pipe heat insulation and 

indoor unit pipe heat insulation and bind them with vinyl tape so that there is no 
gap.

•  For left and left rear piping, butt the connection pipe heat insulation and indoor unit 

pipe heat insulation together and bind them with and vinyl tape so that there is no 
gap.

•  For left and left rear piping, wrap the area which accommodates the rear piping 

housing section with cloth tape.

•  For left and left rear piping, bind the connection cable to the top of the pipe with 

vinyl tape.

•  For left and left rear piping, bundle the piping and drain hose together by wrapping 

them with cloth tape over the range within which they 

Þ

 t into the rear piping 

housing section.

 (2)  Temporarily fasten the connection cable along the connection pipe with vinyl tape. 

(Wrap to about 1/3 the width of the tape from the bottom of the pipe so that water 
does not enter.)

 (3)  Fasten the connection pipe to the outside wall with a saddle, etc.
 (4)  Fill the gap between the outside wall pipe hole and the pipe with sealer so that rain 

water and wind cannot blow in.

 (5)  Fasten the drain hose to the outside wall, etc.

Pipe

Saddle*

Outside wall cap*

Sealer putty*

(Outdoors)

*Field supplied

Wall

Seal A is used when the diameter 

of gas pipe is Ø12.70 or more.

Butt  connection  pipe  (heat 

insulation) against the indoor 

unit pipe (heat insulation) and 

wrap with seal A so that there 

is no gap.

Overlap the insulation

Vinyl tape

Wrap with cloth tape 

Cloth tape

Drain hose

Connection cable

Pipe

Drain hose

Check the following:

GOOD

Drain hose

Saddle

Lifted up

Wave

End in water

Drain hose

Connection pipe

Wall pipe

Connection cable

Left piping

For connection from the left rear

NO GOOD NO GOOD NO GOOD

Pipe

Connection pipe 
(heat insulation)

Bind the pipes together 
so that there is no gap.

Indoor unit pipe 
(heat insulation)

FRONT PANEL REMOVAL AND INSTALLATION

9. 

Intake grille removal

9. 1. 

 (1)  Open the intake grille.
 (2)  While holding the intake grille, lift up the grille stay and secure the intake grille. 
 (3)  Remove  the  screws  from  the  arm-cover  on  the  top  part  of  the  front  panel 

(in 2 places, one on the left and one on the right).

 (4)  Push down the arm-cover grips to release the lock.
 (5)  Open the intake grille until it is horizontal, and pull it towards you to remove it.

(1)

(2)

(3)

(4)

Intake grille

Arm-cover knob

Grille stay

Intake grille

Grille stay

Intake grille installation

9. 2. 

 (1)  Make  the  intake  grille  horizontal  and  push  the  attachment  shafts  into  the  holes  for 

them in the top of the front panel (in 2 places, one on the left and one on the right).

 (2)  While holding the intake grille, lift up the grille stay and secure the intake grille.  
 (3)  Push the arm-cover grips up, and lock the intake grille attachment shaft.
 (4)  Fix the arm-cover on the top part of the front panel using screws (in 2 places, one on 

the left and one on the right).

 (5)  Lift up the intake grille a little, and return the grille stay to its original position.
 (6)  Close the intake grille.

Attachment shaft

Hole

Front panel removal

9. 3. 

 (1)  Remove intake grille. (Reference the intake grille removal.)
 (2)  Remove wire cover. (Remove the 1 screw.)
 (3)  Remove 4 screws.

Screws (4 position)

Wire cover Screw (Wire cover)

 (4)  The front panel is pulled to the front, raising the upper surface, and a front panel is 

removed.

Front panel

Содержание AOYG14LTCN

Страница 1: ... Swedish Polish AIR CONDITIONER ASENNUSOHJE SISÄYKSIKKÖ seinälle asennettava malli Vain valtuutetuille huoltohenkilöille INSTALLASJONSVEILEDNING INNENDØRSENHET veggmontert modell Kun for autorisert servicepersonell INSTALLATIONSHANDBOK INOMHUSENHET väggmonterad Endast för auktoriserad servicepersonal INSTRUKCJA MONTA U URZ DZENIE WEWN TRZNE do monta u ciennego Do u ytku wy cznie przez autoryzowany...

Страница 2: ...use damage or malfunction of your property ABOUT THE UNIT 2 Precautions for using R410A refrigerant 2 1 The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools a...

Страница 3: ...s to secure refrigerant piping ELECTRICAL REQUIREMENT 4 The indoor unit is powered from the outdoor unit or branch box Do not power indoor unit from separate power source WARNING Refer to local codes for acceptable cable type Cable Cable size Remarks Connection cable Type 60245 IEC 57 3 cable Ground 1 Ø 230 V Max Cable Length Limit voltage drop to less than 2 Increase cable gauge if voltage drop i...

Страница 4: ...g When the piping is connected in direction 2 3 4 or 5 use a cutting tool to cut along the groove for the piping that will coming out of the under cover For 5 Left outlet For 4 Left bottom outlet For 3 Right bottom outlet For 2 Right outlet Cutting the hole in the wall for the connecting piping 6 6 1 Cut a 65 mm diameter hole in the wall at the position shown in the following 2 Cut the hole so tha...

Страница 5: ... and left rear piping align the marks on the wall hook bracket and shape the connection pipe Bend the connection piping at a bend radius of 70 mm or more and install no more than 35 mm from the wall After passing the indoor piping and drain hose through the wall hole hang the indoor unit on the hooks at the top and bottom of the wall hook bracket No gap Hexagonal wrench Drain cock Drain cap Instal...

Страница 6: ... line Type 245 IEC57 Inter unit OUTDOOR UNIT or BRANCH BOX Please connect it to the speciÞed terminal INDOOR UNIT TERMINAL Power line Control line Indoor unit wiring 7 2 1 Remove the wire cover Remove the 1 screw 2 Remove the cable clamp Remove the 1 screw 3 Bend the end of the connection cable as shown in the Þgure 4 Connect the end of the connection cable fully inserting into the terminal block ...

Страница 7: ...e Connection cable Pipe Drain hose Check the following GOOD Drain hose Saddle Lifted up Wave End in water Drain hose Connection pipe Wall pipe Connection cable Left piping For connection from the left rear NO GOOD NO GOOD NO GOOD Pipe Connection pipe heat insulation Bind the pipes together so that there is no gap Indoor unit pipe heat insulation FRONT PANEL REMOVAL AND INSTALLATION 9 Intake grille...

Страница 8: ...R UNIT PCB TERMINAL Front panel installation 9 4 1 First Þt the lower part of the front panel and insert top and bottom hooks 2 top sides 7 bottom sides 2 center Indoor unit Bottom holes 3 position Bottom hooks 3 position Bottom holes 4 position Center holes 2 position Center hooks 2 position Top hooks 2 position Top holes 2 position Indoor unit Front panel Bottom hooks 2 position Bottom hooks 2 p...

Страница 9: ...CN8 Relay wire Notice 2 Clasp Connector CND01 Relay control board Clasps 2 Notice the installing direction of the relay control board The elevation of the control box is fit for the recess of the relay control board 1 Insert the relay control board toward 2 clasps 2 Then set the board with the clasp 3 Connect the relay wire terminal to the connector CND01 on the relay control board 4 Connect the r...

Страница 10: ...ding on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire of ex...

Страница 11: ...nsor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly...

Страница 12: ...unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indicator lamp green Troubleshooting w...

Отзывы: