2) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated
amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number
Setting value
Setting description
Factory setting
11
00
Standard (400 hours)
01
Long interval (1,000 hours)
02
Short interval (200 hours)
03
No indication
♦
3) Room temperature control for indoor unit sensor
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
The temperature of the room temperature sensor is corrected as follows:
Corrected temp. = Temp. of the room temp. sensor - Correction temp. value
Example of correction:
When the temperature of the room temp. sensor is 26°C and the setting value is “03”
(-1.0°C), corrected temp. will be 27°C (26°C - [-1.0°C]).
The temperature correction values show the difference from the Standard setting "00" (manufactur-
er’s recommended value).
Function number
Setting value
Setting description
Factory
setting
30
(For cooling)
31
(For heating)
00
Standard setting
♦
01
No correction 0.0 °C
02
-0.5 °C
More cooling
Less heating
03
-1.0 °C
04
-1.5 °C
05
-2.0 °C
06
-2.5 °C
07
-3.0 °C
08
-3.5 °C
09
-4.0 °C
10
+0.5 °C
Less cooling
More heating
11
+1.0 °C
12
+1.5 °C
13
+2.0 °C
14
+2.5 °C
15
+3.0 °C
16
+3.5 °C
17
+4.0 °C
- 32 -
11-1. Function settings by using remote controller
11. Function settings
WALL MOUNTED
ASYG07-14KMCC
WALL MOUNTED
ASYG07-14KMCC
Содержание AOYG07KMCC
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07KMCC ASYG09KMCC ASYG12KMCC ASYG14KMCC ...
Страница 42: ... 38 13 2 Others 13 Optional parts WALL MOUNTED ASYG07 14KMCC WALL MOUNTED ASYG07 14KMCC ...
Страница 43: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07KMCC AOYG09KMCC AOYG12KMCC AOYG14KMCC ...