Total Pipe Length
FULL CHARGE AMOUNT
MODEL NAME
COOLING CAPACITY
HEATING CAPACITY
POWER SUPPLY
(V)
FREQUENCY
RUNNING CURRENT
(A)
INPUT
(kW)
EER
(kW/kW)
AIR CIRCULATION HIGH
ELECTRICAL SPECIFICATIONS
COMPRESSOR
FAN MOTOR
TYPE
DISCRIMINATION
(220) - 230 - (240)
TNB220FPBM9
REFRIGERANT
R410
3,300 g
COOLIING
HEATING
COOLIING
HEATING
COOLIING
HEATING
TYPE
Cooling & Heating
AOY30LMAW4
8.0 kW
9.6 kW
9.7
10.5
2.22
2.40
3.60
4.00
50 Hz
3,300 m3/hr
Hermetic type, Inverter,
4 poles, 3-phase,
DC motor, Twin Rotary
MAX PIPE LENGTH (each unit)
MAX PIPE LENGTH (total)
50 m
60 m
70 m
CHARGELESS
ADDITIONAL CHARGE
3,300 g
3,550 g
3,800 g
MEASUREMENT
25 g/m
50 m
25 m
MIN PIPE LENGTH (each unit)
5 m
70 m
MAX ELEVATION (between indoor units)
10 m
MAX ELEVATION (between indoor and outdoor units)
10 m
830 x 900 x 330 mm
68 kg / 78 kg
OUTDOOR UNIT
WEIGHT
DIMENSIONS
MFE-60PO
820 r.p.m.
H x W x D
Net / Gross
HI-SPEED ( COOL )
780 r.p.m.
HI-SPEED ( HEAT )
DISCRIMINATION
2
2005.05.17
Содержание AOY30LMAW4
Страница 4: ...OUTLINE AND DIMENSIONS INDOOR UNIT Unit mm 1 120 626 711 626 711 321 224 3 2005 05 02 ...
Страница 5: ...Unit mm OUTDOOR UNIT 900 21 370 830 9 40 31 330 400 650 Air Flow 12 4 2005 04 11 ...
Страница 8: ...OUTDOOR UNIT 7 2005 04 05 INDOOR UNIT A INDOOR UNIT B INDOOR UNIT C INDOOR UNIT D TO POWER SOURCE ...
Страница 29: ...0504G2817 ...