Fujitsu AOY17AN Скачать руководство пользователя страница 9

En-8

To Set the Thermostat

Press the TEMPERATURE set button (Fig. 5 

I

).

button:

Press to increase the thermostat setting.

button:

Press to lower the thermostat setting.

Thermostat setting range:

COOLING MODEL

Cooling/Drying ................. 18 to 30 °C
Fan .................................... 17 to 30 °C

HEAT & COOL

Heating ............................. 16 to 30 °C

MODEL

Cooling/Drying ................. 18 to 30 °C

About three seconds later, the entire display will reappear.

NOTE:

The thermostat setting should be considered a standard value, and may differ
somewhat from the actual room temperature.

During Fan mode, set the unit to “– –” for continuous fan operation regardless of
room temperature. [COOLING MODEL ONLY]

The thermostat cannot be used to set room temperature during the FAN mode
(the temperature will not appear on the remote control unit’s display).

[HEAT & COOL MODEL (Reverse Cycle) ONLY]

To Set the Fan Speed

Press the FAN CONTROL button (Fig. 5 

L

).

Each time the button is pressed, the fan speed changes in the following order:

AUTO

HIGH

MED

LOW

About three seconds later, the entire display will reappear.

When set to AUTO:

Cooling :

Operation begins and as the room temperature approaches that of
the thermostat setting, the fan speed switches to the low setting.

Fan: [COOLING MODEL]

Fan speed is selected automatically in accordance with nearby room
temperature.

Fan: [HEAT & COOL MODEL (Reverse Cycle)]

Fan operation will alternate between low speed and off.

* Heating :

The fan operates at low speed at the beginning of operation or other-
wise when the temperature of the emitted air is relatively low; the fan
speed increases as the temperature of the emitted air rises.

However, the fan will operate at very low speed when the air issued
from the indoor unit is low (

 P. 7).

To Stop Operation

Press the START/STOP button.

Example:

When set to 26 °C

Example:

When set to AUTO

s

s

s

s

* During Heating mode:

Set the thermostat to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling and Dry modes
will not operate if the thermostat is set
higher than the actual room temperature
(in Cooling mode, the fan alone will oper-
ate).

During Fan mode:

You can not use the unit to heat and cool
your room.

OPERATION

Содержание AOY17AN

Страница 1: ...PERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED E nglis h OPERATING MANUAL P N9363577044 Indoor Unit AS Y17AS AS Y17R S Outdoor Unit AOY17AN AOY17R N OPERATING MANUAL ROOM AIR CONDITIONER S PLIT TYPE ...

Страница 2: ...he condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the inta...

Страница 3: ...ting are applicable only to HEAT COOL MODEL Reverse Cycle For details of operation see the pages indicated by the mark NAME AND FUNCTION OF PARTS Fig 4 Fig 5 Fig 1 Fig 7 Fig 6 M J L K G I H N R P Q O Z Y X W U T V S 9 4 1 3 5 0 B 2 A 6 7 D C 8 E F ...

Страница 4: ...down direc tion A Right left Louvers P 10 behind Air flow direction Louvers Control airflow in the horizontal right left di rection B Pipe Unit C Power Plug D Drain Hose Moisture condensed from the air during Cool ing and Drying operations is drained here Fig 4 Outdoor Unit E Air inlet Rear and side panels F Air outlet Warm or cool air is blown out Fig 5 Remote Control Unit G SLEEP Button P 12 H M...

Страница 5: ...ng range becomes appre ciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the power plug to an electrical point 2 Open the Intake Grille 3 Set the POWER switch to ON Fig 2 3 4 Close the Intake Grille Opening closing the Intake Grille 1 Press both lower sides of the intake grille until you hear a clicking s...

Страница 6: ...und will be heard If no beep is heard press the remote control unit button again Remote Control Unit Holder Signals will not be transmitted properly if a wall cur tain or other object is between the air conditioner and the remote control unit The air conditioner may fail to operate properly if strong direct light is allowed to strike the signal re ceiver Use a curtain to shade strong sunlight from...

Страница 7: ...ature Example When set to normal operate at low speed If the room temperature subse quently changes the air conditioner will once again se lect the appropriate operation Heating Cooling to ad just the temperature to the value set in the thermostat The monitor operation range is 2 C relative to the ther mostat setting If the mode automatically selected by the unit is not what you wish see page 7 an...

Страница 8: ...om without changing its temperature Heating Use to warm your room When Heating mode is selected the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit ...

Страница 9: ...perature approaches that of the thermostat setting the fan speed switches to the low setting Fan COOLING MODEL Fan speed is selected automatically in accordance with nearby room temperature Fan HEAT COOL MODEL Reverse Cycle Fan operation will alternate between low speed and off Heating The fan operates at low speed at the beginning of operation or other wise when the temperature of the emitted air...

Страница 10: ... down ward to the floor area as the room is gradually warmed the flaps will change to permit double direction heating Room heats up Downward Double direction If you wish to select a different airflow direction you may use the remote control unit s airflow direction button to choose a different setting WARNING Automatic Airflow Direction Adjustment Always use the remote control unit s airflow direc...

Страница 11: ...en the efficiency of cooling and drying modes the airflow direc tion louvers should be set within the following ranges For Cooling Horizontal slight downward diagonal For Heating Double direction downward diagonal downward Adjusting the Right Left Direction Adjust with the right left louvers Manually adjust the right left louvers to the desired direction Horizontal Slight downward diagonal Downwar...

Страница 12: ...ntrol unit is set to the correct current time P 5 To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Change the Timer Settings Perform steps 2 and 3 To Stop Air Conditioner Operation while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change operating conditions Mode Fan Speed Ther...

Страница 13: ...matically modifies the thermostat setting in accordance with the time setting When the set time has elapsed the air conditioner completely stops During Heating operation HEAT COOL MODEL Reverse cycle only When the SLEEP timer is set the thermostat setting is automatically lowered 1 C every thirty minutes When the thermostat has been lowered a total of 4 C the thermostat setting at that time is mai...

Страница 14: ...e Power Cord Check the power cord occasionally to confirm that it is not damaged by cuts or abrasions If you discover damage to the cord consult authorized service person nel CARE AND MAINTENANCE Inspections and Repairs Depending on the conditions of use the internal parts of an air conditioner will be come dirty after about two or three seasons of use and performance may be affected For this reas...

Страница 15: ...llowed to collect in the air filter the airflow will be reduced leading to reduced performance and increased operating noise Be sure to clean the filters at the beginning of the operating season and about every two weeks during periods of frequent operation 1 Removing the Air Filter 1 Remove the intake grille 2 Hold on to the air filter handles and pull up slightly to release the two lower hooks T...

Страница 16: ...e result of minute expansion and contraction of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry op...

Страница 17: ...the problem persists after performing these checks or if you notice burning smells or the TIMER indicator lamp Fig 3 7 flashes immediately stop operation disconnect the power supply and consult authorized service personnel Consult authorized service personnel for any repairs WARNING Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Please read and understand the...

Страница 18: ...iefly for about 6 to 12 minutes During Automatic Defrosting operation the OPERATION in dicator lamp red will flash WhenIndoorandOutdoorTemperaturesareHigh When both indoor and outdoor temperatures are high dur ing use of the heating mode the outdoor unit s fan may stop at times Low Ambient Cooling When the outdoor temperature drops the outdoor unit s fans may switch to Low Speed Temperature and Hu...

Страница 19: ...ER 1 220 240 V 50 Hz COOLING CAPACITY kW 4 75 4 90 4 70 4 80 POWER INPUT kW 1 75 1 85 1 70 1 78 CURRENT A 8 0 7 8 7 9 7 6 ENERGY EFFICIENCY RATIO kW kW 2 71 2 65 2 77 2 70 HEATING CAPACITY kW 5 00 5 15 POWER INPUT kW 1 85 1 92 CURRENT A 8 6 8 2 ENERGY EFFICIENCY RATIO kW kW 2 70 2 68 MAX PRESSURE kPa 2 840 REFRIGERANT R22 g 1 300 1 500 DIMENSIONS WEIGHT NET INDOOR UNIT HEIGHT mm 285 WIDTH mm 900 D...