Self-diagnosis function table (Flashing LED Display)
Applicable model : ASY18LSBCW
* Detailed Trouble Display (secondary level) can be indicated by pressing Test Operation button.
ERROR CONTENTS
Error
Operation
Timer
Error
Operation
Timer
Serial signal
Normal
1 sec
Serial reverse signal error
0.1sec
0.5sec
When a signal is not read continuously for 10 secs
from power relay ON immediately after operation starts
>>Cooling 0 code transmission, automatic reset
When a signal is not read for 20 secs thereafter
>>Trouble display continues and power relay OFF
>>Permanent stop
When a signal is not read continuously for 10 secs
from power relay ON immediately after operation starts
>>Cooling 0 code transmission, automatic reset
When a signal is not read for 20 secs thereafter
>>Trouble display continues and power relay OFF
>>Permanent stop
error
blinking at operation start up
blinking
2 times
Signal reverse signal error
0.1sec
0.5sec
during operation
blinking
3 times
Serial forward signal error
0.1sec
0.5 sec
Normal Serial Forward Signal can not be
at operation start up
blinking
4 times
received more than 10 secs
>>Releases when it becomes normal
Serial forward signal error
0.1sec
0.5sec
Normal Serial Forward Signal can not be
during operation
blinking
5 times
received more than 10 secs ( after receiving
effective forward transfer signal)
>>Releases when it becomes normal
Indoor unit
0.5sec
0.1sec
Indoor temperature
0.1sec
0.5sec
Thermistor detection value is open when
thermistor
2 times
blinking thermistor open
blinking
2 times
AC plug is inserted
error
>>Releases when value becomes normal
Pipe thermistor
0.1sec
0.5sec
Thermistor detection value is open or short
open or short
blinking
3 times
when AC plug is inserted
>>Releases when value becomes normal
Outdoor unit
0.5sec
0.1sec
Discharge thermistor
0.1sec
0.5sec
Thermistor detection value is open or short
thermistor
3 times
blinking open or short
blinking
2 times
error
>>Outdoor unit stops
Releases when it becomes normal
Heat exchanger
0.1sec
0.5sec
Thermistor detection value is open
thermistor open
blinking
3 times
>>Outdoor unit stops
Releases when it becomes normal
Outdoor temperature
0.1sec
0.5sec
Thermistor detection value is open or short
thermistor open or short
blinking
4 times
>>Outdoor unit stops
Releases when it becomes normal
Indoor unit
0.5sec
0.1sec
Forced automatic SW
0.1sec
0.5sec
Forced Auto SW is ON for more than
control error
4 times
blinking welded
blinking
2 times
10 secs continuously
>>Error is indicated while it is ON
Normal Operation other than error indication
Main relay welded
0.1sec
0.5sec
Serial Reverse Signal is received 1 min.
blinking
3 times
after Main relay becomes OFF
>>Error is indicated while serial reverse
signal is input on normal operation
Normal operation except error indication
Power interruption error
0.1sec
0.5sec
50/60Hz is not detected after 4 secs of
blinking
4 times
power ON.
>>Error is indicated and unit is stopped