Error

Operation

Timer

Error

Operation

Timer

Outdoor unit

0.5sec

0.1sec

Current trip

0.1sec

0.5sec

Current trip error is 2nd time within

control error

5 times

blinking

blinking 

2 times

start up

>>Permanent stop

CT abnormal

0.1sec

0.5sec

Current detection value is 0A for more

blinking 3 

times

than 1 sec when compressor is
operated at more than 56rps

>>Automatic release after 3 min. ST

Compressor rotation

0.1sec

0.5sec

Compressor location detection error (incl.

error

blinking

5 times

failed start up) for 3 times

>>Permanent stop

Indoor fan

0.5sec

0.1sec

Abnormal lock

0.1sec

0.5sec

Detected rotation is 0 r.p.m. at start up or

motor error

6 times

blinking

blinking 

2 times

at 56 secs after Fan mode is selected

>>Permanent stop

Abnormal rotation

0.1sec

0.5sec

Detected rotation is 1/3 of target r.p.m. at

blinking 3  3 times

start up or at 56 secs after Fan mode is
selected

>>Permanent stop

Refrigerant

0.5sec

0.1sec

Discharge temperature

0.1sec

0.5sec

Discharge Temperature protection

cycle error

7 times

blinking

abnormal

blinking 

2 times

(Discharge temperature is 110degC)

operated 2 times

>>Permanent stop

Cooling high pressure

0.1sec

0.5sec

High pressure rise protection (Outdoor

abnormal rise

blinking 3 

times

heat exchanger temperature is 65degC)
operated
>>Comp. OFF (releases after 3min.ST)

Error is indicated while 3 min.ST

Optional

0.5sec

0.1sec

Active filter voltage

0.1sec

0.5sec

Active Filter voltage error operated 3 times

function

8 times

blinking

abnormal (3rd time)

blinking

2 times

error

>>Permanent stop

PFC circuit

0.1sec

0.5sec

abnormal

blinking

4 times

>>Permanent stop

Active filter foltage

0.1sec

0.5sec

Active Filter Module error or open

abnormal (1st time)

blinking

3 times

detection protection operated

>>Automatic release after 3 min. ST

Trouble Display (primary)

Detailed Trouble Display (by Test Button)

Detailed Error Item

O

u

td

o

o

r

Outdoor unit fan drive 
system abnormal

0.1sec

0.5sec

When outdoor fan abnormal  fan motor
duty abnormal operated 5 times

blinking 6 

times

>>Permanent stop

2005.02.16

8

Содержание AOY12LFBC

Страница 1: ... 1 DIMENSIONS 2 REFRIGERANT SYSTEM DIAGRAM 3 CIRCUIT DIAGRAM 4 ERROR CONTENTS 5 INDOOR PCB CIRCUIT DIAGRAM 6 OUTDOOR PCB CIRCUIT DIAGRAM 7 DISASSEMBLY ILLUSTRATION 9 PARTS LIST 12 14 STANDARD ACCESSORIES Models Indoor unit Outdoor unit ASY9LSBCW AOY9LFBC ASY12LSBCW AOY12LFBC ...

Страница 2: ...AIR CIRCULATION Hi m hr 3 C 635 H 670 C 595 H 645 2 60 3 60 3 0 3 8 0 62 0 82 4 19 4 39 1 3 FAN MOTOR TYPE Hermetic type 4 pole 3 phase DC inverter motor Rotary DISCRIMINATION DA 89 X 1F 20F REFRIGERANT R410A g 1 050 950 POWER SOURCE V 230 HI SPEED r p m C 1 300 H 1 390 INDOOR UNIT MED SPEED r p m C 1 120 H 1 200 LO SPEED r p m C 950 H 1 000 QUIET r p m C 700 H 760 C 1 370 H 1 440 C 1 150 H 1 200 ...

Страница 3: ...DIMENSIONS ASY12LSBCW AOY12LFBC Models ASY9LSBCW AOY9LFBC unit mm 275 2 000 215 790 2005 01 24 2 ...

Страница 4: ...e Muffler Muffler 4 Way valve Expansion valve Heat exchanger INDOOR Heat exchanger OUTDOOR AOY9LFBC 2Pass AOY12LFBC 4Pass Compressor Cooling Heating ASY12LSBCW AOY12LFBC Models ASY9LSBCW AOY9LFBC Refrigerant pipe diameter Liquid 1 4 6 35 mm Gas 3 8 9 52 mm 2005 03 16 3 ...

Страница 5: ...4 Way Valve Assy PCB MAIN Power Relay Compressor Thermistor pipe temp Test Thermistor pipe Thermistor Discharge Pipe Thermistor outdoor temp Display Board Controller PCB Power 102 C Thermal Fuse 1 2 3 4 5 6 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 4 5 1 2 3 4 5 1 2 3 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 1 2 1 2 1 2 3 4 5 1 2 3 4 5 6 7 1 2 3 4 5 6 1 2 3 4 5 6 1 2 2 1 2 1 3 4 5 6 7 8 9 10 11 1...

Страница 6: ...5V 5V I C201 GP 1UM261RK R201 47 1 4W C202 47 10V D208 SLR 325 ORG D205 SLR 325 GRN D204 SLR 325 GRN D201 SLR 325 RED C201 0 1 F INDICATOR PCB K02CB 0300HSD D0 CN5 2P SCN CN4 2P SAN ROOM TEMPERATURE THERMISTOR PIPE TEMPERATURE THERMISTOR CN4 1 BLACK CN4 2 BLACK CN5 2 GRAY CN5 1 GRAY uPD780024ASGB X52 8ET A I C 1 C23 1000P R Q4 DTC124EUA 5V R21 10K 1 8W R20 1 0K 1 8W R24 330 1 8W 5V 15V I C9 PS2561...

Страница 7: ...114EUA I C103 3 uPC324 R130 100K 1 I C103 2 uPC324 C117 1000P B 5V R162 68K 1 R160 68K 1 2 3 1 7 6 1 5V 5V R112 10K 1 5V 5V EXPANSION VALVE M CN40 B6B XARK 1 A RED CN71 B04B PASK 1 WHITE DISCHARGE TEMPERATURE THERMISTOR PIPE TEMPERATURE THERMISTOR OUTDOOR TEMPERATURE THERMISTOR 4 WAY VALVE SERIAL EARTH UL1015 AWG16 GREEN UL1015 AWG14 WHITE UL1015 AWG20 RED L N W201 UL1015 AWG14 BLACK F201 20A 250V...

Страница 8: ...tection value is open when thermistor 2 times blinking thermistor open blinking 2 times AC plug is inserted error Releases when value becomes normal Pipe thermistor 0 1sec 0 5sec Thermistor detection value is open or short open or short blinking 3 times when AC plug is inserted Releases when value becomes normal Outdoor unit 0 5sec 0 1sec Discharge thermistor 0 1sec 0 5sec Thermistor detection val...

Страница 9: ...selected Permanent stop Refrigerant 0 5sec 0 1sec Discharge temperature 0 1sec 0 5sec Discharge Temperature protection cycle error 7 times blinking abnormal blinking 2 times Discharge temperature is 110degC operated 2 times Permanent stop Cooling high pressure 0 1sec 0 5sec High pressure rise protection Outdoor abnormal rise blinking 3 times heat exchanger temperature is 65degC operated Comp OFF r...

Страница 10: ...DISASSEMBLY ILLUSTRATION 51 53 2 3 1 6 7 1 4 5 5 ASY12LSBCW Models ASY9LSBCW 2005 01 14 9 ...

Страница 11: ...188 32 24 30 29 20 31 23 43 46 48 236 37 26 28 52 36 42 39 33 21 38 27 61 1 61 2 32 ASY12LSBCW Models ASY9LSBCW 2005 01 14 10 ...

Страница 12: ...AOY12LFBC Models AOY9LFBC 2005 01 24 11 11 26 27 37 38 29 42 45 5 16 17 25 18 19 32 12 23 10 7 15 2 1 13 14 40 9 36 39 24 8 41 46 42 4 3 21 22 43 ...

Страница 13: ...06755010 9313130091 9313131050 20 Gear A 9309994003 21 Casing Assy 9312112081 23 Cover Casing B 9311916017 9309994003 9312112081 9311916017 9307836015 26 Clamp Motor 9310102008 27 Shaft Holder C Assy 9306628017 28 Drain Hose Assy 9310357019 9310102008 9306628017 9310357019 29 Drain Cap Assy 9304150008 30 Wire Clamper 9311946014 31 Box Switch 9309996014 32 Cover Switch 9311863014 33 Evaporator Tota...

Страница 14: ...3 Thermistor Outdoor Temp 45 Solenoid 46 Condenser Total Assy 9314032011 0501454012 0600382018 313714262805 313728262708 9300089012 9306489038 9307271014 9309913011 9310229026 9310979013 9312680016 9312972029 9313452018 9313806026 9313807016 9313808013 9313990015 9313815011 9313941017 9313987015 9313989026 9313992019 9313995027 9314022012 9314093012 9314278013 9314507014 9314554018 9314557019 9601...

Страница 15: ...010 9308846099 0600185534 0700076046 9310519004 9312153015 9311925033 Remote control unit Battery penlight Cloth tape Tapping screw big Wall hook bracket STANDARD ACCESSORIES 9306602017 Tapping screw small 3 x 12 4 x 25 0700019036 Air cleaning filter Air cleaning filter frame 2005 01 14 14 ...

Страница 16: ...0412G2714 ...

Отзывы: