– 2 –
HI-SPEED
(dB)
C 39 - 39
C 39 - 39
C 40 - 40
C 40 - 40
H 38 - 38
H 39 - 39
MED-SPEED
(dB)
C 38 - 38
C 38 - 38
C 39 - 39
C 39 - 39
INDOOR UNIT
H 35 - 35
H 35 - 35
LO-SPEED
(dB)
C 36 - 36
C 36 - 36
C 37 - 37
C 37 - 37
H 31 - 31
H 30 - 30
QUIET
(dB)
C 34 - 34
C 34 - 34
C 35 - 35
C 36 - 36
H 30 - 30
H 29 - 29
OUTDOOR UNIT
(dB)
C 45 - 46
C 45 - 46
C 47 - 48
C 46 - 47
H 46 - 47
H 48 - 49
NOISE LEVEL
Note : Noise was measured in accordance with JIS standards, Japan.
Between 5 m and 10 m, when using a connection pipe other than that in the table, charge additional refrigerant with 20 g /1 m as the criteria.
ADDITIONAL REFRIGERANT CHARGE
Refrigerant suitable for a piping length of 5 m is charged in the outdoor unit at the factory.
When the piping is longer than 5 m, additional charging is necessary.
For the additional amount, see the table below.
PIPE LENGTH
5 m
10 m
15 m
ADDITIONAL REFRIGERANT
None
100 g
200 g
WEIGHTS
INDOOR UNIT
GROSS / NET
(kg)
10 / 8
OUTDOOR UNIT
33 / 30
35 / 32