SAFETY DEVICES
10.
Protection form
Model
AOU9RLFW1
AOU12RLFW1
Circuit protection
Current fuse
(IN THE INVERTER CASE)
250V 20A
250V 5A
Current fuse
(MAIN PRINTED
CIRCUIT BOARD)
─
250V 15A
250V 3.15A
Fan motor protection Terminal protection program
OFF: 212±27°F (100±15°C)
ON: 203±18°F (95±10°C)
OFF: 302±27°F (150±15°C)
ON: 230±18°F (120±15°C)
Compressor
protection
Terminal protection program
COMPRESSOR TEMP.
OFF:230°F (110°C)
ON:After 7 minutes