To Select Mode Operation

1

Press the START/STOP button (Fig.6 

R

).

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

The air conditioner will start operating.

2

Press the MASTER CONTROL button (Fig.6 

K

) to se-

lect the desired mode.

Each time the button is pressed, the mode will change in the following
order.

AUTO

COOL

DRY

   HEAT

      FAN

About three seconds later, the entire display will reappear.

To Set the Thermostat

Press the SET TEMP. button (Fig. 6 

L

).

 

button: 

Press to raise the thermostat setting.

 button: 

Press to lower the thermostat setting.

Thermostat setting range:

AUTO .................................. 18-30 °C
Heating ............................... 16-30 °C
Cooling/Dry ........................ 18-30 °C

The thermostat cannot be used to set room temperature during the FAN mode (the
temperature will not appear on the Remote Controller’s Display).

About three seconds later, the entire display will reappear.

The thermostat setting should be considered a standard value, and may differ
somewhat from the actual room temperature.

To Set the Fan Speed

Press the FAN CONTROL button (Fig. 6 

Q

).

Each time the button is pressed, the fan speed changes in the following order:

AUTO

HIGH

MED

LOW

QUIET

About three seconds later, the entire display will reappear.

When set to AUTO:

Heating :

Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the temperature
of the air issued from the indoor unit is low.

Cooling :

As the room temperature approaches that of the thermostat setting,
the fan speed becomes slower.

Fan

:

The fan runs at the low fan speed.

The fan will operate at a very low setting during Monitor operation and at the
start of the Heating mode.

SUPER QUIET Operation

When set to Quiet:

SUPER QUIET operation begins. The indoor unit’s airflow will be reduced for qui-
eter operation.

SUPER QUIET operation cannot be used during Dry mode. (The same is true
when dry mode is selected during AUTO mode operation.)

During Super Quiet operation, Heating and Cooling performance will be reduced
somewhat. If the room does not warm up/ cool down when using SUPER QUIET
Operation, please adjust the air conditioner’s Fan Speed.

OPERATION

s

s

s

s

Example: 

When set to COOL.

Example: 

When set to 26 °C.

Example: 

When set to AUTO.

s

s

s

s

t

t

9315345301_OM_EN_body

3/22/10, 10:40 AM

6

Содержание AOTR24LFL

Страница 1: ...IR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product 9315345301_OM_EN_cover 3 22 10 10 42...

Страница 2: ...conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage Do not place animals...

Страница 3: ... UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the oper ating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist milde...

Страница 4: ...g 3 Fig 4 Fig 7 To facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actral operation however the display will only show those indicators appropriate to the current op eration Fig 6 N Z a Q R K L M J O X S T U V P W b c d Y 9315345301_OM_EN_body 3 22 10 10 40 AM 3 ...

Страница 5: ...ay Fan Speed Display a Temperature SET Display b COIL DRY Display c SLEEP Display d SWING Display NAME OF PARTS Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s us...

Страница 6: ...rrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 X Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 P to adjust the clock to the current time button Press to advance the time button Press to revers...

Страница 7: ...h time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of ...

Страница 8: ...r which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPE...

Страница 9: ... display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the...

Страница 10: ...operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the thermo stat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the thermostat setting is ...

Страница 11: ...ion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 S Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Cooling Dry modes 4 5 6 ...

Страница 12: ...d mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using the following range according to the current airflow direc tion Airflow direction is 1 4 for coolin...

Страница 13: ... of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash...

Страница 14: ...y can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the used dirty air cleaning f...

Страница 15: ...ng During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at v...

Страница 16: ...ficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When usi...

Страница 17: ...of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other ...

Страница 18: ...9315345301_OM_EN_body 3 22 10 10 40 AM 17 ...

Страница 19: ...9315345301_OM_EN_body 3 22 10 10 40 AM 18 ...

Страница 20: ...9315345301_OM_EN_body 3 22 10 10 40 AM 19 ...

Отзывы: