Air Cleaning Filter Installation

1. Open the Intake Grille and remove the Air

filters.

2. Install the Air cleaning filter set (set of 2).

1

Set the air cleaning filter into the air cleaning filter
frame.

2

Engage the latch at both ends of the filter with the
two hooks at the rear of the air cleaning filter frame.

Take care that the air cleaning filter does not project be-
yond the frame.

3

Engage the four fixing locations at the top and bot-
tom of the air cleaning filter frame with the hooks of
the air filter.

3. Install the two Air filters and close the

Intake Grille.

When air cleaning filters are used, the effect will increased
by setting the fan speed to “High”.

Air cleaning filter set

Air cleaning filter frame

Air cleaning filter

Hook (2 places at the rear)

Latch (2 places)

Rear of the filter

Fixing location, hook (4 places)

Replacing dirty Air cleaning filters

Replace filters with the following components (purchased
separately).

POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA03-2

Negative air ions deodorizing filter: UTR-FA03-3

1. Open the Intake Grille and remove the Air

filters.

2. Replace them by two new Air cleaning

filters.

1

Remove the old air cleaning filters in reverse order of
their installation.

2

Install in the same way as for installation of the air
cleaning filter set.

3. Install the two Air filters and close the

Intake Grille.

In regard to the Air Cleaning Filters

POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)

The Air Cleaning Filters are disposable filters. (They can
not be washed and reused.)

For storage of the Air Cleaning Filters, use the filters as
soon as possible after the package has been opened.
(The air cleaning effect decreases when the filters are left
in the opened package)

Generally, the filters should be exchanged about every
three months.

Please buy delicated air cleaning filters (UTR-FA03-2) (Sold
separately) to exchange the used dirty air cleaning filters.

[Negative air ions deodorizing filter (one sheet) — light blue]

The filters should be exchanged about every three years
so as to maintain the deodorizing effect.

Filter frame is not a one-off product.

Please buy delicated deodorizing filter (UTR-FA03-3) (Sold
separately) when exchanging the filters.

Maintenance of Deodorizing Filters

In order to maintain the deodorizing effect, please clean the
filter in the follow way once three months.

1

Remove the deodorizing filter.

2

Clean with water and dry in the air.
1) Flush the filters with high-pressure hot water until

the surface of the filters are covered with water.
Please flush with diluent neutral detergent.
Never wash by reaming or rubbing, otherwise it
will damage the deodorizing effect.

2) Rinse with water flow.
3) Dry in shade.

3

Reinstall the deodorizing filter.

CLEANING AND CARE

Air Filter

(Right & Left)

Air Filter

(Right & Left)

Air Filter(Right & Left)

Air Filter

(Right & Left)

Содержание AOTR09LCC

Страница 1: ...CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product ...

Страница 2: ...since special purpose tools and specified cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the a...

Страница 3: ...OL UNIT The Wireless Remote Control Unit allows convenient con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to res...

Страница 4: ...TS Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 6 P b a S T M O L Q Y N U V W R X c d e Z Fig 7 To facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actral operation however the display will only show those indicators appropriate to the current op eration ...

Страница 5: ...ply Plug F Power Supply Cord G Air Cleaning Filter Fig 5 Outdoor Unit H Intake Port I Outlet Port J Pipe Unit K Drain port bottom Fig 6 Remote Control Unit L SLEEP button M MASTER CONTROL button N SET TEMP button O COIL DRY button P Signal Transmitter Q TIMER MODE button R TIMER SET button S FAN CONTROL button T START STOP button U SET button V SWING button W RESET button X TEST RUN button This bu...

Страница 6: ... signal receiver Fig 1 4 to operate correctly Operating Range About 7 meters When a signal is properly received by the air conditioner a beeping sound will be heard If no beep is heard press the Remote Control Unit button again Remote Control Unit Holder PREPARATION CAUTION Take care to prevent infants from accidentally swallowing batteries When not using the Remote Control Unit for an extended pe...

Страница 7: ...h time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of ...

Страница 8: ...ill operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle ...

Страница 9: ...onds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operatio...

Страница 10: ...Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raise...

Страница 11: ...the heat ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings R DANGER When adjusting the Right Left Louvers it is necessary to stop the Air Conditioner first and make sure that it stops completely before adjusting...

Страница 12: ...Fig 7 c and the COIL DRY Indicator Lamp orange Fig 3 8 will light Then it will disappear after 20 minutes To cancel COIL DRY Operation Press the START STOP button Fig 6 T during COIL DRY Operation The COIL DRY Display Fig 7 c and the COIL DRY Indicator Lamp orange Fig 3 8 will go out Then the operation stops About COIL DRY Operation Press the COIL DRY button again during COIL DRY Operation COIL DR...

Страница 13: ...lle 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and w...

Страница 14: ...o Air filters and close the Intake Grille In regard to the Air Cleaning Filters POLYPHENOL CATECHIN AIR CLEANING FILTER one sheet The Air Cleaning Filters are disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened pack...

Страница 15: ...ner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will sto...

Страница 16: ...ufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When u...

Страница 17: ... operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under...

Страница 18: ...17 ...

Страница 19: ...18 ...

Страница 20: ...19 ...

Отзывы: