- 8 -
W
A
LL
MOU
N
TED
ASTG30, 34
KMTA
3. Specifications
Type
Wall mounted
Inverter heat pump
Model name
ASTG30KMTA
ASTG34KMTA
Power supply
240 V ~ 50 Hz
Available voltage range
198—264 V
Star rating index
10-star standard
Cooling
2.0
2.0
Heating
3.0
2.5
Capacity
Cooling
Rated
kW
8.50
9.40
Btu/h
29,000
32,000
Min.—Max.
kW
2.9—10.5
2.9—11.2
Btu/h
9,900—35,800
9,900—38,200
Heating
Rated
kW
9.00
10.30
Btu/h
30,700
35,100
Min.—Max.
kW
2.2—11.2
2.7—11.7
Btu/h
7,500—38,200
9,200—39,900
Input power
Cooling
Rated
kW
2.46
2.78
Min.—Max.
0.58—3.85
0.59—4.03
Heating
Rated
2.34
2.84
Min.—Max.
0.50—4.01
0.60—4.24
Fan
W
63
63
Current
Cooling
Rated
A
10.4
11.7
Heating
10.1
12.9
EER
Cooling
kW/kW
3.45
3.38
COP
Heating
3.84
3.63
Sensible capacity
Cooling
kW
6.00
6.95
Power factor
Cooling
%
98.5
99
Heating
97
99
Moisture removal
L/h (pints/h)
2.5 (4.4)
3.5 (6.16)
Maximum operating current *1
Cooling
A
17.0
19.5
Heating
17.0
20.5
Fan
Airflow rate
Cooling
HIGH
l/s (m
3
/h)
389 (1,400)
MED
319 (1,150)
LOW
256 (920)
QUIET
200 (720)
Heating
HIGH
389 (1,400)
MED
319 (1,150)
LOW
256 (920)
QUIET
200 (720)
Type × Q'ty
Cross flow fan × 1
Motor output
W
80
Sound pressure level *2
Cooling
HIGH
dB(A)
51
52
MED
46
47
LOW
40
41
QUIET
33
34
Heating
HIGH
51
51
MED
44
44
LOW
39
38
QUIET
33
33
Heat exchanger type
Dimensions (H × W × D)
mm
Main: 448 × 900 × 30
Sub1: 126 × 900 × 13.3
Sub2: 84 × 900 × 13.3
Fin pitch
Main: 1.2, Sub: 1.4
Rows × Stages
Main: 3 × 28, Sub1: 1 × 6, Sub2: 1 × 4
Pipe type
Copper tube
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net
mm
340 × 1,150 × 280
Gross
450 × 1,270 × 405
Weight
Net
kg
18
Gross
24
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas
Ø 15.88 (Ø 5/8)
Method
Flare
Drain hose
Material
PVC
Size
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller type
Wireless (Wired [option])
International Protection rating
IPX0
NOTES:
Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 7.5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*1: Maximum current is maximum value when operated within the operation range.
*2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Содержание AOTG30KMTA
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASTG30KMTA ASTG34KMTA ...
Страница 15: ... 11 WALL MOUNTED ASTG30 34KMTA 5 Wiring diagram ...
Страница 21: ... 17 WALL MOUNTED ASTG30 34KMTA 8 2 Sound level check point 0 8 m 1 m Microphone Microphone ...
Страница 44: ... 40 WALL MOUNTED ASTG30 34KMTA ...
Страница 45: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOTG30KMTA AOTG34KMTA ...
Страница 56: ... 52 OUTDOOR UNIT AOTG30 34KMTA 3 Refrigerant circuit 3 1 Model AOTG30KMTA ...
Страница 57: ... 53 OUTDOOR UNIT AOTG30 34KMTA 3 2 Model AOTG34KMTA ...
Страница 58: ... 54 OUTDOOR UNIT AOTG30 34KMTA 4 Wiring diagrams 4 1 Model AOTG30KMTA ...
Страница 59: ... 55 OUTDOOR UNIT AOTG30 34KMTA 4 2 Model AOTG34KMTA ...