Fujitsu AOT90EP Скачать руководство пользователя страница 14

13

AUTO

TIMER
MODE

START/STOP

CLOCK ADJUST

SET TIME

TEMP./DAY

FAN

CONTROL

MASTER

CONTROL

2

1

AUTO

DEFROST TEST

SET

ZONE

DAY OFF

ENERGY SAVE

If there is a problem with the air conditioner, it will stop run-
ning and “EE: EE” will be displayed instead of the clock.

(1) If the operation lamp is on then press the START/

STOP button to turn it off.

(2) Press the SET TIME (

) and the SET TEMP./DAY (

)

buttons at the same time for more than three seconds
to start the self diagnosis check.
An error code will be displayed in the clock display area.

(3) Press the SET TIME (

) and the SET TEMP./DAY (

)

buttons again for more than three seconds to end the
self diagnosis check.

ERRORS AND SELF DIAGNOSIS

Room temperature sensor shortcircuited

Indoor heat exchanger temperature
sensor open

Indoor heat exchanger temperature
sensor shortcircuited

Outdoor heat exchanger temperature
sensor open

Outdoor heat exchanger temperature
sensor shortcircuited

Power source connection error

Float switch operated

Outdoor temperature sensor open

Outdoor temperature sensor
shortcircuited

Discharge pipe temperature sensor open

Discharge pipe temperature sensor
shortcircuited

Outdoor high pressure abnormal

Discharge pipe temperature abnormal

Model abnormal

Indoor fan abnormal

Outdoor signal abnormal

Outdoor EEPROM abnormal

Error Code

Error Code

s

t

s

t

Error contents

Communication error
(indoor unit            remote controller)

Communication error
(indoor unit           outdoor unit)

Room temperature sensor open

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.

See Page

NORMAL

FUNCTION

Содержание AOT90EP

Страница 1: ...KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P N9365350010 Indoor Unit ART90EL 3 ART90TL 3 Outdoor Unit AOT90EP 3 AOT90TP 3 OPERATING MANUAL AIR CONDITIONER DUCT TYPE ...

Страница 2: ...arting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at least one metre away from eithe...

Страница 3: ...rt 3 Drain Pipe Main 4 Drain Pipe Safety Fig 2 Outdoor Unit 5 Air intake 6 Air outlet Fig 3 Remote Controller 7 START STOP Button 8 Operation Lamp 9 ENERGY SAVE Button 0 DAY OFF Button A ENERGY SAVE Lamp B ZONE Control Button C SET Button D ZONE Control Lamp E CLOCK ADJUST Button F TIMER MODE Button G SET TIME Button H SET TEMP DAY Button I FAN CONTROL Button J MASTER CONTROL Button K Remote Contr...

Страница 4: ...nd the time display stops flashing PREPARATION CLOCK DAY AUTO TIMER MODE SET ZONE START STOP CLOCK ADJUST SET TIME TEMP DAY FAN CONTROL MASTER CONTROL 2 1 AUTO DEFROST TEST DAY OFF ENERGY SAVE 3 2 1 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle To Select Mode Operation 1 Press the START STOP button The unit will start and the remote controller s operation la...

Страница 5: ...he timer time Use to advance the time forward Use to turn the time back Press once to move the time 1 minute hold down and the time will move 10 minutes at a time Example Setting the OFF TIMER to 23 35 c To confirm or Change Settings Before Starting Operation To confirm settings Press the TIMER MODE button once The timer setting information will be displayed for 15 seconds after the TIMER MODE but...

Страница 6: ...nd then proceed as fol lows 1 Press the TIMER MODE button so that WEEKLY ap pears on the display The display now shows the current day by DAY CODE the first ON and OFF times for the day the WEEKLY 1 times the fan speed and the operating mode The top time value gives the ON time and the bottom value gives the OFF time If either time is not set the corresponding time display is blank 2 Press the SET...

Страница 7: ...ompleting the WEEKLY 1 settings for that day The display switches to WEEKLY 2 and the day s second ON time be gins flashing 8 Repeat the operations described in Steps 4 to 7 to set the second ON and OFF times for the day the WEEKLY 2 times When you press the SET button after setting the WEEKLY 2 OFF time the system registers the WEEKLY 2 settings for the day and returns you to the WEEKLY 1 ON time...

Страница 8: ...play 2 Press the SET TEMP DAY button to select the day that you want check 3 Press the SET TIME button or to switch between the WEEKLY 1 or WEEKLY 2 time displays Cancelling Selected Time Settings Press the START STOP button to stop the air conditioner and then proceed as fol lows 1 Carry out steps 1 to 3 of the Setting Up the Weekly Timer Operation procedure to select the day you want to edit 2 P...

Страница 9: ...y flashes briefly and then the clock display appears c c c c Example Changing the WEEKLY 2 ON setting for day 5 Friday from 14 00 to 15 30 TIMER DAY WEEKLY AUTO ON OFF TIMER MODE SET ZONE START STOP CLOCK ADJUST SET TIME TEMP DAY FAN CONTROL MASTER CONTROL 2 1 AUTO DEFROST TEST DAY OFF ENERGY SAVE 2 TIMER DAY WEEKLY AUTO ON OFF TIMER MODE SET ZONE START STOP CLOCK ADJUST SET TIME TEMP DAY FAN CONT...

Страница 10: ...eding day DAY OFF day C CLOCK TIMER TEMP WEEKLY AUTO DAY OFF TIMER SET TIME TEMP DAY FAN 2 1 HIGH AUTO COOL DEFROST TEST Using the DAY OFF Setting Press the START STOP button to stop the air conditioner and then proceed as fol lows 1 Carry out steps 1 to 2 of the Setting Up the Weekly Timer Operation procedure to select the day that you want to set as the DAY OFF 2 Press the DAY OFF button The DAY...

Страница 11: ...AVE button while the air conditioner is on it will change to the conservation mode If you press the ENERGY SAVE button while the unit is in the timer mode ON timer WEEKLY timer the unit will go into the conserva tion mode when the unit starts with the timer If you turn off the air conditioner while in the conservation mode the mode will be shut off The temperature set on the remote controller will...

Страница 12: ...al injury could result CARE AND MAINTENANCE CAUTION Installing the Air Filter Be sure the filter is always installed in the inlet air grille of the indoor unit Filters can be purchased through your local dealer Cleaning the Air Filter If dirt is allowed to collect in the air filter the airflow will be reduced leading to reduced performance and increased operation noise Be sure to clean the filters...

Страница 13: ...he following details regarding this air conditioner Low Ambient Cooling When the outdoor temperature drops the outdoor unit s fans may switch to Low Speed or one of the fans may stop inter mittently Should the power supply to the air conditioner be inter rupted by a power failure the air conditioner will restart automatically in the previously selected mode once the power is restored AUTO Restart ...

Страница 14: ...sensor open Discharge pipe temperature sensor shortcircuited Outdoor high pressure abnormal Discharge pipe temperature abnormal Model abnormal Indoor fan abnormal Outdoor signal abnormal Outdoor EEPROM abnormal Error Code Error Code s t s t Error contents Communication error indoor unit remote controller Communication error indoor unit outdoor unit Room temperature sensor open TROUBLESHOOTING Inst...

Страница 15: ... outdoor unit will stop If you wish to warm the room further set the thermostat for a higher setting During Heating operation the unit will temporarily stop opera tion between 2 and 16 minutes as the Automatic Defrosting mode operates During Automatic Defrosting operation DEFROST will be shown on the remote controller display The fan may stop when the unit is monitoring the room s tem perature Dur...

Отзывы: