TIMER FUNCTIONS

OFF timer (See page 5.)

Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops
after the set time has passed. The timer can be set up to 24 hours in advance.

ON timer (See page 5.)

Use this timer function to start air conditioner operation. The timer operates and air condition operation starts
after the set time has passed. The timer can be set up to 24 hours in advance.

WEEKLY timer (See page 6.)

Use this timer function to set operating times for each day of the week.
Use the DAY OFF setting to switch off timed operation for a selected day in the coming week.
Because all days can be set together, the weekly timer can be used to repeat the timer settings for all of the days.

Temperature SET BACK timer (See page 8.)

Use this timer function to change the set temperature in the operation times set for each day of the week.
This can be used together with other timer settings.

ON/OFF TIMER

Press the timer mode button to se-
lect the ON timer or OFF timer.

2

Press the DELETE button to cancel the timer mode.

The timer mode can also be canceled by changing the timer mode using the timer mode button.

1

CLOCK ADJUST

NON

STOP

OFF

TIMER

ON

TIMER

WEEKLY

TIMER

No display

SU MO TU WE TH FR SA

Press the set time buttons to set the time.
After the time is set, the timer will start automatically.
The amount of time until the OFF timer operates that is dis-
played on the timer display decreases as time passes.

From 1 to 24 hours

ex. OFF timer set for 6 hours

● 

To cancel

DELETE

To set the ON/OFF timer

Содержание AOT36RP

Страница 1: ...G MANUAL AIR CONDITIONER Indoor Unit ART60RU ART45RU ART36RU Outdoor Unit AOT60RP AOT45RP AOT36RP DUCT TYPE SU MO TU WE TH FR SA AM PM 3 6 9 12 15 18 21 KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED ...

Страница 2: ...t expose the air conditioner directly to water Do not operate the air conditioner with wet hands Turn off power source when not using the unit for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place a...

Страница 3: ...R Button 6 ENERGY SAVE Button 7 Timer Mode CLOCK ADJUST Button 8 DAY DAY OFF Button 9 SET BACK Button 0 Set Time Button A DELETE Button DAY OFF DELETE SET ENERGY SAVE THERMO SENSOR SET BACK DAY CLOCK ADJUST SU MO TU WE TH FR SA 3 6 9 12 15 18 21 D 2 7 8 9 0 A B G F E H I C 1 3 4 5 6 B SET Button C Operation Lamp D Timer and Clock Display E Operation Mode Display F Fan Speed Display G Operation Loc...

Страница 4: ...ime Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday 10 00 Press again to end CLOCK ADJUST SU MO TU WE TH FR SA 1 3 4 AUTO COOL DRY HEAT FAN AUTO HIGH MED LOW Temperature setting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 16 to 30 C Lower Raise Operation lamp Air conditioner ON Lit brightly Air condit...

Страница 5: ...ction is activated the mark appears If any button is pressed during the child lock the CL display flashes Room temperature sensor selection Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is ...

Страница 6: ...y timer can be used to repeat the timer settings for all of the days Temperature SET BACK timer See page 8 Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings ON OFF TIMER Press the timer mode button to se lect the ON timer or OFF timer 2 Press the DELETE button to cancel the timer mode The ti...

Страница 7: ...g Up to two ON and OFF times can be set per day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the SET button for 2 seconds or more SET To delete the operating time DELETE If the DELETE button is pressed during steps 3 or 4 the operating ti...

Страница 8: ...button for 2 seconds or more to com plete the DAY OFF setting 2 4 DAY OFF DAY SET 3 DAY OFF DAY SU MO TU WE TH FR SA 3 6 9 12 15 18 21 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the ne...

Страница 9: ...the SET BACK confirmation display SET BACK SET SU MO TU WE TH FR SA 3 6 9 12 15 18 21 DAY OFF DAY 1 3 SET 2 SET 4 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 ex When setting all days together Temperature setting Press the set temperature buttons to set the temperature from 16 C to 30 C ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the SET button for 2 sec onds or more to complete the tempe...

Страница 10: ...erformance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with an other kind of heating appliance Heat pump air co...

Страница 11: ...se a vacuum cleaner to remove dust and dirt from the air filter or wash in a synthetic detergent After washing dry in a shaded place then reinstall When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel When clean...

Страница 12: ...ndensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan is temporarily stop to al low internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the indoor and the outdoor unit will stop If you wish...

Страница 13: ...u notice burning smells stop operation immediately turn off the electrical breaker and consult with authorized service personnel TROUBLESHOOTING TEMPERATURE AND HUMIDITY RANGE Outdoor temperature About 0 to 43 C Indoor temperature About 18 C to 32 C Indoor humidity Below approximately 80 If the air conditioner is used continu ously for many hours water may condense on the surface and drip Outdoor ...

Страница 14: ... ...