background image

3

PREPARATORY OPERATION

To set the operation mode

● 

Operation mode setting

● 

Room temperature setting

● 

Fan speed setting

OPERATION

Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

To start/stop operation

CLOCK ADJUST

Press the timer mode (CLOCK
ADJUST) button for 2 seconds
or more. The time display on
the remote controller will flash.

2

DAY OFF

DAY

SU       MO       TU       WE       TH       FR       SA

Press the DAY button and select the current day.

 appears around the selected day.

Press the set time buttons to set the current time.
Press repeatedly to adjust the current time in 1-
minute increments. Press and hold to adjust the
current time in 10-minute increments.

ex. Monday 10:00

Press again to end.

CLOCK ADJUST

SU MO TU WE TH FR SA

1

3

4

AUTO

COOL

DRY

HEAT

FAN

AUTO

HIGH

MED

LOW

Temperature setting range

AUTO ............................................... 18 to 30 °C
COOL/DRY ....................................... 18 to 30 °C
HEAT ................................................ 16 to 30 °C

Lower

Raise

Operation lamp

Air conditioner ON: Lit brightly
Air conditioner OFF: Not lit

Press the start/stop button.

Press the master control button to set the operation mode.
If DRY is selected, the fan speed will be set to AUTO.

Press the set temperature buttons to set the room temperature.

Press the fan control button to set the fan speed.

Set the current day and time

Содержание AOT30LMBDL

Страница 1: ...6 OPERATING MANUAL AIR CONDITIONER Indoor Unit ART30LU ART36LU Outdoor Unit AOT30LMBDL AOT36LMADL DUCT TYPE SU MO TU WE TH FR SA AM PM 3 6 9 12 15 18 21 KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED ...

Страница 2: ...ot expose the air conditioner directly to water Do not operate the air conditioner with wet hands Turn off power source when not using the unit for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place ...

Страница 3: ...R Button 6 ENERGY SAVE Button 7 Timer Mode CLOCK ADJUST Button 8 DAY DAY OFF Button 9 SET BACK Button 0 Set Time Button A DELETE Button DAY OFF DELETE SET ENERGY SAVE THERMO SENSOR SET BACK DAY CLOCK ADJUST SU MO TU WE TH FR SA 3 6 9 12 15 18 21 D 2 7 8 9 0 A B G F E H I C 1 3 4 5 6 B SET Button C Operation Lamp D Timer and Clock Display E Operation Mode Display F Fan Speed Display G Operation Loc...

Страница 4: ...set the current time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday 10 00 Press again to end CLOCK ADJUST SU MO TU WE TH FR SA 1 3 4 AUTO COOL DRY HEAT FAN AUTO HIGH MED LOW Temperature setting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 16 to 30 C Lower Raise Operation lamp Air conditioner ON Lit br...

Страница 5: ...ion is activated the mark appears If any button is pressed during the child lock the CL display flashes Room temperature sensor selection Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is lo...

Страница 6: ...y timer can be used to repeat the timer settings for all of the days Temperature SET BACK timer See page 8 Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings ON OFF TIMER Press the timer mode button to se lect the ON timer or OFF timer 2 Press the DELETE button to cancel the timer mode The ti...

Страница 7: ...g Up to two ON and OFF times can be set per day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the SET button for 2 seconds or more SET To delete the operating time DELETE If the DELETE button is pressed during steps 3 or 4 the operating ti...

Страница 8: ...button for 2 seconds or more to com plete the DAY OFF setting 2 4 DAY OFF DAY SET 3 DAY OFF DAY SU MO TU WE TH FR SA 3 6 9 12 15 18 21 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the ne...

Страница 9: ...DAY 1 3 SET 2 SET 4 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 ex When setting all days together Temperature setting Press the set temperature buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the SET button for 2 sec onds or more to complete the temperature SET BACK timer settings SET...

Страница 10: ...erformance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with an other kind of heating appliance Heat pump air co...

Страница 11: ...se a vacuum cleaner to remove dust and dirt from the air filter or wash in a synthetic detergent After washing dry in a shaded place then reinstall When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel When clean...

Страница 12: ...g During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to the Auto matic Defrosting operation When Heating operation starts the fan stops temporarily to al low internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the indoor and the outdoor unit will stop If you wish to warm the room ...

Страница 13: ... notice burning smells stop operation immediately turn off the electrical breaker and consult with authorized service personnel TROUBLESHOOTING TEMPERATURE AND HUMIDITY RANGE Outdoor temperature About 0 to 43 C Indoor temperature About 18 C to 32 C Indoor humidity Below approximately 80 If the air conditioner is used continu ously for many hours water may condense on the surface and drip Outdoor t...

Отзывы: