OPERATING TIPS

Should the power supply to the air conditioner be inter-
rupted by a power failure, the air conditioner will restart
automatically in the previously selected mode once the
power is restored.

Should a power failure occur during TIMER operation,
the timer will be reset and the unit will begin (or stop)
operating under the new timer setting. In this event, the
TIMER indicator lamp (green) will flash (see page 4).

Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
disconnect the power supply, reconnect it, and then use
the remote control unit to resume operation.

AUTO Restart

In Event of Power Interruption

Dry Mode

About 0 to 43 °C

About 18 to 32 °C

About 80 % or less

If the unit is used for long peri-
ods under high-humidity condi-
tions, condensation may form
on the surface of the indoor
unit, and drip onto the floor or
other objects underneath.

Outdoor temperature

Indoor temperature

Indoor humidity

Cooling Mode

About 0 to 43 °C

About 18 to 32 °C

About 80 % or less

If the unit is used for long peri-
ods under high-humidity condi-
tions, condensation may form
on the surface of the indoor
unit, and drip onto the floor or
other objects underneath.

Heating Mode

About –10 to 21 °C

About 30 °C or less

Temperature and Humidity Range

If the air conditioner is used under higher temperature conditions than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

Do not use this unit for any purposes other than the Cooling, (Heating), Dehumidifying, and air-circulation of rooms in
ordinary dwellings.

Содержание AOT24PMAL

Страница 1: ...OOM AIR CONDITIONER WALL MOUNTED TYPE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL Indoor Unit AST24PBA AST30PBA Outdoor Unit AOT24PMAL AOT30PMAL P N9370143010 ...

Страница 2: ...damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any e...

Страница 3: ...ONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possi ble through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the oper ating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE INTAKE GRILLE The indoor unit s INTAKE G...

Страница 4: ...3 A 0 1 3 9 B C 7 6 5 4 8 2 D SWING SWING TIMER OPERATION G E F Fig 2 Fig 3 Fig 4 NAME OF PARTS Fig 6 Fig 1 Fig 8 Fig 7 Fig 5 G E F ...

Страница 5: ... flash simultaneously To stop the test operation mode either press the TEST RUN button once again or press the START STOP button to stop the air conditioner V Remote Control Unit Display Fig 8 W Transmit Indicator X Clock Display Y Operating Mode Display Z Timer Mode Display Fan Speed Display Temperature Set Display Timer Set Indicator Temperature Set Indicator Fig 1 Indoor Unit 1 Operating Contro...

Страница 6: ...de to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the ...

Страница 7: ...nit s display About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear...

Страница 8: ...ed to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic De frosting operation the OPERATION indicator lamp red will flash and the heat operation will be interrupted...

Страница 9: ... STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Change th...

Страница 10: ...on When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the thermo stat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time Set time 1 hour 1 C 2 C U...

Страница 11: ...djustments within the ranges shown above Fig 10 ADJUSTING THE DIRECTION OF AIR CIRCULATION Vertical up down direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION VERTICAL SET button Horizontal right left direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION HORIZONTAL SET button DANGER Never place fingers or foreign objects in...

Страница 12: ...he air UP DOWN direction flaps in the range 4 to 6 for long periods of time since water vapor may condense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING will light In this mode the RIGHT LEFT air direction louvers will swing automat...

Страница 13: ...he intake grille fully to remove 2 Clean with water Remove dust with a vacuum cleaner wipe the unit with warm water then dry with a clean soft cloth 3 Replace the intake grille 1 Holding the intake grille horizontally fasten the two upper hooks on the unit 2 Press the intake grille down at the lower sides to close Intake Grille Air filter handle Hooks two places Intake Grille Hooks two places Befo...

Страница 14: ...of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from ...

Страница 15: ...ciple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughou...

Страница 16: ... long peri ods under high humidity condi tions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath Outdoor temperature Indoor temperature Indoor humidity Cooling Mode About 0 to 43 C About 18 to 32 C About 80 or less If the unit is used for long peri ods under high humidity condi tions condensation may form on the surface of the indoor unit a...

Страница 17: ... 3 300 600 3 950 CURRENT A 11 0 2 8 14 0 13 8 2 8 16 5 ENERGY EFFICIENCY RATIO 2 70 2 42 HEATING CAPACITY W 8 500 1 400 9 500 9 500 1 400 10 200 POWER INPUT W 2 740 500 3 350 3 320 500 3 950 CURRENT A 11 5 2 3 14 0 13 9 2 3 16 5 MAX PRESSURE MPa 2 7 REFRIGERANT R22 g 2 200 DIMENSIONS WEIGHT NET INDOOR UNIT HEIGHT 320 mm WIDTH 1 120 mm DEPTH 220 mm WEIGHT 16 kg OUTDOOR UNIT HEIGHT 900 mm WIDTH 900 ...

Отзывы: