background image

5

Fig. 1 Indoor Unit

1

Operating Control Panel (Fig. 2)

2

MANUAL AUTO button

3

Remote Control Signal Receiver

4

Indicator Lamps (Fig. 3)

5

OPERATION Indicator Lamp (red)

6

TIMER Indicator Lamp (green)

7

SWING Indicator Lamp (orange)

(VERTICAL SWING)

8

SWING Indicator lamp (orange)

(HORIZONTAL SWING)

If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a
fault has occurred with the timer setting

(See Page 16 Auto Restart).

9

Intake Grille (Fig. 4)

0

Air Filter

A

UP/DOWN Air Direction Flaps

B

RIGHT/LEFT Air Direction Louvers

(behind UP/DOWN Air Direction Flaps)

C

Drain Hose

D

Power Supply Plug

E

Power Supply Cord

F

Air Cleaning Filter (optional)

Fig. 5 Outdoor Unit

G

Intake Port

H

Outlet Port

I

Pipe Unit

Fig. 6 Remote Control Unit

J

SLEEP Button

K

MASTER CONTROL Button

L

SET TEMP./SET TIME Buttons (

)

M

Signal Transmitter

N

TIMER Button

O

FAN CONTROL Button

P

START/STOP Button

Q

Battery compartment lid

Inside of the battery compartment lid (Fig. 7)

R

AIR FLOW DIRECTION Button

S

ENERGY SAVE Button

T

CODE CHANGE (Slide Switch)

Switching the remote control unit code.
(Max. 4 units)

U

TIME ADJUST Button

V

TEST RUN Button

This button is used when installing the air
conditioner and should not be used under
normal conditions as it will cause the air
conditioner’s thermostat function to oper-
ate incorrectly.

If this button is pressed during normal op-
eration, the unit will switch to test opera-
tion mode, and the indoor unit’s OPERA-
TION indicator lamp and TIMER indicator
lamp will begin to flash simultaneously.

To stop the test operation mode, either
press the TEST RUN button once again, or
press the START/STOP button to stop the
air conditioner.

W

ACL Button

X

Remote Control Unit Display (Fig. 8)

Y

Transmit Indicator

Z

Clock Display

[

Operating Mode Display

\

Timer Mode Display

]

Fan Speed Display

`

Temperature Set Display

a

Timer Set Indicator

b

Temperature Set Indicator

Содержание AOT20AZ

Страница 1: ...D TYPE OPERATING MANUAL P N9360503015 02 Indoor Unit AST20AG AST20RG AST24AG AST24RG AST30AG AST30RG Outdoor Unit AOT20AZ AOT20RZ AOT24AB AOT24RZ AOT30AB AOT30RB KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED ...

Страница 2: ...n off the circuit breaker and consult authorized service personnel Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operat...

Страница 3: ...lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air dir...

Страница 4: ...SWING SWING CLOCK OFF ON TIMER RESET TIMER SLEEP H M OFF AUTO COOL DRY FAN ENERGY SAVE HEAT ON A AUTO HIGH MED LOW J M N O P Q Y a b Z R S T U V W K L X CLOCK COOL AUTO Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 1 Fig 8 Fig 7 ...

Страница 5: ...ER Button O FAN CONTROL Button P START STOP Button Q Battery compartment lid Inside of the battery compartment lid Fig 7 R AIR FLOW DIRECTION Button S ENERGY SAVE Button T CODE CHANGE Slide Switch Switching the remote control unit code Max 4 units U TIME ADJUST Button V TEST RUN Button This button is used when installing the air conditioner and should not be used under normal conditions as it will...

Страница 6: ...es Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the time button Press to reverse the time Each time the buttons are pressed the time will be a...

Страница 7: ...be used to set room temperature during the FAN mode the temperature will not appear on the remote control unit s display About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed change...

Страница 8: ...t satisfactory see page 7 for instructions on changing the mode setting HEAT COOL DRY FAN Heating Use to warm your room When Heating mode is selected the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temp...

Страница 9: ...dicator lamp green will light 3 Press the TIMER button to select the PROGRAM timer operation either OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation to occur first The PROGRAM timer will begin operation If the ON timer has been selected to operate first the unit will stop operating at this point About five...

Страница 10: ...to set the duration of time in which the unit does not operate To Use the SLEEP timer While the air conditioner is operating or stopped press the SLEEP button Both the indoor unit s OPERATION indicator lamp red and the TIMER indicator lamp green will light To Change the Timer Settings Press the SLEEP button once again and set the time using the SET TIME buttons Set the time while the Timer Mode Di...

Страница 11: ...air direction and room temperature should be considered carefully when making settings Example When set to vertical air direc tion Example When set to horizontal air di rection Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION VERTICAL SET button Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow Direction Setting 1 2 3 4 Dur...

Страница 12: ...ange 5 to 7 for long periods of time since water vapor may con dense near the outlet louvers and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING orange will light In this mode the RIGHT LEFT air direction louvers will swing automatically to direct the airflow...

Страница 13: ...re of 4 C less than that set ENERGY SAVE setting During Cooling Dry operation The thermostat temperature setting increases by 1 C as soon as the ENERGY SAVE button is pressed and then increases by another 1 C after one hour has passed Afterwards energy consumption is saved by continuing to cool or dry at a thermostat temperature of 2 C more than that set ENERGY SAVE setting To Cancel the ENERGY SA...

Страница 14: ...urned properly to their holes in the panel 2 Close the intake grille For purposes of example the illustration shows the unit without intake grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling If...

Страница 15: ...action of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitte...

Страница 16: ...ent heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When using ...

Страница 17: ...t 0 to 21 C AST20RG AST24RG Models About 5 to 21 C AST30RG Model About 30 C or less COOLING MODEL HEAT COOL MODEL Reverse Cycle Outdoor temperature Indoor temperature Indoor humidity If the air conditioner is used under higher temperature conditioner than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is use...