15

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the
power supply plug, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to disconnect the power supply plug or turn off your circuit breaker to
ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops.

Water is produced from
the outdoor unit.

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the power supply plug is disconnected and then re-
connected to a power outlet, the protection circuit will operate
for about 3 minutes, preventing unit operation during that pe-
riod.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

*

During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

*

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

*

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

*

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.

*

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
indicator lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

*

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

16

16

16

7

7

16

NORMAL

FUNCTION

Содержание AOT20AN

Страница 1: ...TED TYPE OPERATING MANUAL P N9360503022 Indoor Unit AST20AG AST20RG AST24AG AST24RG AST30AG AST30RG Outdoor Unit AOT20AN AOT20RN AOT24AN AOT24RN AOT30AB AOT30RB KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED ...

Страница 2: ...hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not ap...

Страница 3: ...lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air dir...

Страница 4: ...ET TIME SET TEMP MASTER CONTROL FAN CONTROL START STOP SET ENERGY SAVE TIME ADJUST TEST RUN ACL SET SWING SWING CLOCK OFF ON TIMER RESET TIMER SLEEP H M OFF AUTO COOL DRY FAN ENERGY SAVE HEAT ON A AUTO HIGH MED LOW H K L M N O W Z X Y P Q R S T U I J V CLOCK COOL AUTO Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 1 Fig 8 Fig 7 ...

Страница 5: ...ROL Button N START STOP Button O Battery compartment lid Inside of the battery compartment lid Fig 7 P AIR FLOW DIRECTION Button Q ENERGY SAVE Button R CODE CHANGE Slide Switch Switching the remote control unit code Max 4 units S TIME ADJUST Button T TEST RUN Button This button is used when installing the air conditioner and should not be used under normal conditions as it will cause the air condi...

Страница 6: ...es Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the time button Press to reverse the time Each time the buttons are pressed the time will be a...

Страница 7: ...be used to set room temperature during the FAN mode the temperature will not appear on the remote control unit s display About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed change...

Страница 8: ...tisfactory see page 7 for instructions on changing the mode setting HEAT COOL DRY FAN Heating Use to warm your room When Heating mode is selected the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperat...

Страница 9: ...dicator lamp green will light 3 Press the TIMER button to select the PROGRAM timer operation either OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation to occur first The PROGRAM timer will begin operation If the ON timer has been selected to operate first the unit will stop operating at this point About five...

Страница 10: ...tion of time in which the unit does not operate To Use the SLEEP timer While the air conditioner is operating or stopped press the SLEEP button Both the indoor unit s OPERATION indicator lamp red and the TIMER indicator lamp green will light To Change the Timer Settings Press the SLEEP button once again and set the time using the SET TIME buttons Set the time while the Timer Mode Display is flashi...

Страница 11: ...air direction and room temperature should be considered carefully when making settings Example When set to vertical air direc tion Example When set to horizontal air di rection Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION VERTICAL SET button Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow Direction Setting 1 2 3 4 Dur...

Страница 12: ...ange 5 to 7 for long periods of time since water vapor may con dense near the outlet louvers and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING orange will light In this mode the RIGHT LEFT air direction louvers will swing automatically to direct the airflow...

Страница 13: ...t set ENERGY SAVE setting During Cooling Dry operation The thermostat temperature setting increases by 1 C as soon as the ENERGY SAVE button is pressed and then increases by another 1 C after one hour has passed Afterwards energy consumption is saved by continuing to cool or dry at a thermostat temperature of 2 C more than that set ENERGY SAVE setting To Cancel the ENERGY SAVE Press the ENERGY SAV...

Страница 14: ...urned properly to their holes in the panel 2 Close the intake grille For purposes of example the illustration shows the unit without intake grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling If...

Страница 15: ...action of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitte...

Страница 16: ...ent heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When using ...

Страница 17: ...derneath Heating Mode About 0 to 21 C AST20RG AST24RG Models About 5 to 21 C AST30RG Model About 30 C or less COOLING MODEL HEAT COOL MODEL Reverse Cycle Outdoor temperature Indoor temperature Indoor humidity If the air conditioner is used under higher temperature conditioner than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dr...

Отзывы: