En-3

Fig. 6 Remote Control Unit

J

 SLEEP button

K

 MODE button

L

  SET TEMP. button ( 

 

/

 

 

M

 Signal Transmitter

N

  TIMER MODE button

O

  TIMER SET (   /   ) button

P

 FAN button

Q

 START/STOP button

R

  SET button (Vertical)

S

  SET button (Horizontal) 

T

 SWING button

U

 RESET button 

V

  TEST RUN button

  This button is used when installing the condi-

tioner, and should not be used under normal 
conditions, as it will cause the air conditioner’s 
thermostat function to operate incorrectly.

  If this button is pressed during normal opera-

tion, the unit will switch to test operation mode, 
and the Indoor Unit’s OPERATION Indicator 
Lamp and TIMER Indicator Lamp will begin 
to 

fl

 ash simultaneously.

  To stop the test operation mode, press the 

START/STOP button to stop the air condi-
tioner.

W

 CLOCK ADJUST button

X

  Remote Control Unit Display (Fig. 7)

Y

 Transmit Indicator

Z

 Clock Display

[

  Operating Mode Display

\

  T imer Mode Display

]

  Fan Speed Display

`

  Temperature SET Display 

a

 SLEEP Display

b

 SWING Display

NAME OF PARTS

  Refer to the folded out page on the cover.

Fig. 1 Indoor Unit

1

  Operating Control Panel (Fig. 2)

2

 MANUAL AUTO button

 

When kept on pressing the MANUAL AUTO 
button for more than 10 seconds, the forced 
cooling operation will start.

 

The forced cooling operation is used at the 
time of installation.

 

Only for authorized service personnel’s use.

 

When the forced cooling operation starts by 
any chance, press the START/STOP button 
to stop the operation.

3

  Indicator (Fig. 3)

4

  Remote Control Signal Receiver

5

  OPERATION Indicator Lamp (red)

6

  TIMER Indicator Lamp (green)

 

If the TIMER indicator lamp 

fl

 ashes when the 

timer is operating, it indicates that a fault has 
occurred with the timer setting (See Page 14 
Auto Restart).

7

  SUPER QUIET Indicater Lamp (orange)

8

  Intake Grille (Fig. 4)

9

 Front Panel

0

 Air Filter

A

  Air Flow Direction Louver

B

 Power Diffuser

C

 Right-Left Louver

 

(behind Air Flow Direction Louver)

D

 Drain Hose

E

  Air Cleaning Filter

Fig. 5 Outdoor Unit

F

 Intake Port

G

 Outlet Port

H

 Pipe Unit

I

  Drain port (bottom)

9315345332-03_OM.indb   3

9315345332-03_OM.indb   3

2/25/2013   10:09:48 AM

2/25/2013   10:09:48 AM

Содержание AOBR24JFC

Страница 1: ...t AOBR24JFC COOL MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MMANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA FUJITSU GENERAL LIMITED 9315345332 03_Cover indd 1 9315345332 03_Cover indd 1 2 25 2013 10 12 17 AM 2 25 2013 10 12 17 AM ...

Страница 2: ...tainers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air...

Страница 3: ...tainers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air...

Страница 4: ...WN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the operating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth...

Страница 5: ... Display b SWING Display NAME OF PARTS Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling opera...

Страница 6: ...included with this product 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 W Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 O to adjust the clock to the current time button Press to advance the time button Press to reverse ...

Страница 7: ...t the Fan Speed Press the FAN button Fig 6 P Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermostat setting the fan speed becomes slower Fan The fan runs at the low fan speed The fan will operate at a very low se...

Страница 8: ...alue set in the thermostat The monitor operation range is 2 C relative to the thermostat setting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at...

Страница 9: ...ut the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Contr...

Страница 10: ...n automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automatically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has ...

Страница 11: ...he 3 range When used in a room with infants children elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 R Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Cooling Dry modes 1 ...

Страница 12: ...on the left right swing operation will stop CLEANING AND CARE Before cleaning the air conditioner be sure to turn it off and disconnect the Power Supply Cord Be sure the Intake Grille Fig 1 8 is installed securely When removing and replacing the air filters be sure not to touch the heat exchanger as personal injury may result CAUTION To avoid excessive wear of the part and components or malfunctio...

Страница 13: ...connect the two lower tabs and pull out 2 Remove dust with a vacuum cleaner or by washing After washing allow to dry thoroughly in a shaded place 3 Replace the Air Filter and close the Intake Grille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example t...

Страница 14: ...used For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters Negative air ions d...

Страница 15: ...after stopping the unit the sound of water flowing in the air conditioner s piping may be heard Also noise may be particularly noticeable for about 2 to 3 minutes after starting operation sound of coolant flowing During operation a slight squeaking sound may be heard This is the result of minute expansion and contraction of the front cover due to temperature changes Smells Some smell may be emitte...

Страница 16: ...ating 7 8 Poor Cooling per formance Is the Air Filter dirty Air the air conditioner s intake grille or outlet port blocked Did you adjust the room temperature settings thermostat correctly Is there a window or door open In the case of Cooling operation is a window allowing bright sunlight to enter Close the curtains In the case of Cooling operation are there heating apparatus and comput ers inside...

Страница 17: ... may stop operation for certain period of time OPERATING TIPS AUTO Restart In Event of Power Interruption The air conditioner power has been interrupted by a power failure The air conditioner will then restart automatically in its previous mode when the power is restored Operated by setting before the power failure If a power failure occurs during TIMER operation the timer will be reset and the un...

Страница 18: ...9315345332 03_OM indb 16 9315345332 03_OM indb 16 2 25 2013 10 09 52 AM 2 25 2013 10 09 52 AM ...

Страница 19: ...t AOBR24JFC COOL MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MMANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA FUJITSU GENERAL LIMITED 9315345332 03_Cover indd 1 9315345332 03_Cover indd 1 2 25 2013 10 12 17 AM 2 25 2013 10 12 17 AM ...

Отзывы: