4) Setting the heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as
shown in the table below.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
31
00
Lower control
01
Slightly warmer control
02
Warmer control
03
5) Auto restart
Enable or disable automatic system restart after a power outage.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Yes
40
00
No
01
* Auto restart is an emergency function such as for power failure etc.
Do not start and stop the indoor unit by this function in normal operation.
Be sure to operate by the control unit, or external input device.
6) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when using the control by Wired remote controller temperature sensor.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
No
42
00
Yes
01
* If setting value is “00”:
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is “01”:
Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor.
7) Cool air prevention
This setting is used to set the fan speed when the compressor stops once the room temperature has reached the set temperature during
heating operation.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Super low
43
00
Follow the setting on
the remote controller
(corresponding to
ventilation)
01
8) Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
A
44
00
B
01
C
02
D
03
9) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Operation/Stop mode
46
00
(Setting forbidden)
01
Forced stop mode
02
Содержание AO*G30LETL series
Страница 2: ...1 INDOOR UNIT DTR_AR064E_01 2013 02 28 DUCT TYPE AR G30LMLE AR G36LMLE ...
Страница 12: ... 01 09 DUCT TYPE AR G30 36LMLE DUCT TYPE AR G30 36LMLE WIRING DIAGRAMS 555 MODEL AR G30LMLE AR G36LMLE ...
Страница 40: ...DTR_AO135E_01 2013 02 28 SINGLE TYPE AO G30LETL AO G36LETL 2 OUTDOOR UNIT ...
Страница 45: ... 02 04 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL WIRING DIAGRAMS 444 MODEL AO G30LETL ...
Страница 46: ... 02 05 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL MODEL AO G36LETL ...
Страница 51: ... 02 10 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL SOUND LEVEL CHECK POINT 88888 ...