SAFETY DEVICES
10.
Protection form
Model
AO
G12LA
AO
G14LA
AO
G18LA
Circuit protection
Current fuse
(NEAR THE TERMINAL)
20A 250V
5A 250V
Current fuse
(MAIN PRINTED
CIRCUIT BOARD)
15A 250V
3.15A 250V
Fan motor protection
Thermal protection
program
OFF : 100
+15
-10
°C
ON : 95
+15
-10
°C
Compressor protection
Terminal protection program
(COMPRESSOR TEMP.)
OFF : 110°C
ON : After 40 minutes and 80°C or less
Thermal protection program
(DISCHARGE TEMP.)
OFF : 110°C
ON : After 7 minutes