REFRIGERANT CIRCUIT

3. 

MODEL

„

„

 : AO

G09LLCB

Refrigerant pipe diameter
Liquid : 1/4" (6.35 mm)
Gas : 3/8" (9.52 mm)

Содержание AO*G09LLCB

Страница 1: ...AIR CONDITIONER Wall Mounted type INDOOR OUTDOOR AS G09LLCB AS G12LLCB AO G09LLCB AO G12LLCB DESIGN TECHNICAL MANUAL ...

Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS G09LLCB AS G12LLCB DTR_AS070E_01 2012 08 30 ...

Страница 3: ...PACITY TABLE 01 08 6 1 COOLING CAPACITY 01 08 6 2 HEATING CAPACITY 01 09 7 FAN PERFORMANCE AND CAPACITY 01 10 7 1 AIR VELOCITY DISTRIBUTION 01 10 7 2 AIR FLOW 01 11 8 OPERATION NOISE 01 13 8 1 NOISE LEVEL CURVE 01 13 8 2 SOUND LEVEL CHECK POINT 01 14 9 ELECTRIC CHARACTERISTICS 01 15 10 SAFETY DEVICES 01 16 11 FUNCTION SETTING 01 17 11 1 INDOOR UNIT Setting by remote controller 01 17 12 OPTIONAL PA...

Страница 4: ...w airflow construction Our quiet operation makes the more comfortable environment in a bed room and a study room etc Powerful operation z z Reach the setting temperature quickly Powerful Setting Temp Normal mode Temperature Time Image Ex Cooling operation Economy operation z z Setting temp is shifted by 1 C automatically Temp Economy operation Shift setting temp Normal operation Ex Cooling operati...

Страница 5: ... 01 02 WALL MOUNTED TYPE AS G09 12LLCB WALL MOUNTED TYPE AS G09 12LLCB Easy maintenance z z Removable washable panel Corresponds to maximum 15m long piping z z ...

Страница 6: ...ake up to go to work OFF 10hours ON 7hours 12 6 9 3 PM11 00 set 12 6 ON 9hours OFF 2hours 9 3 PM9 00 set Sleep timer z z The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling or heating while sleeping Cooling operation dry operation When the sleep timer is set the set temperature automatically rises 1 C every h...

Страница 7: ...h to test operation mode and the Indoor Unit s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation mode press the START STOP button z z to stop the air conditioner 8 FAN button 9 SET button 10 SWING button 11 RESET button TIMER 12 SLEEP TIMER button 13 OFF TIMER button 14 ON TIMER button 15 TIMER CANCEL button 16 Remote controller display...

Страница 8: ... 1 06 0 23 1 30 Heating Rated 0 865 1 080 Min Max 0 21 1 00 0 21 1 84 Current Cooling Rated A 4 0 4 7 Heating 4 7 5 1 EER Cooling kW kW 3 36 3 35 COP Heating 3 70 3 70 SENSIBLE CAPACITY Cooling kW 1 6 2 2 POWER FACTOR Cooling 81 94 Heating 80 92 Moisture removal l h pints h 1 3 2 3 1 8 3 2 Maximum operating current 1 Cooling A 6 0 7 0 Heating 6 0 9 5 Fan Air flow rate Cooling High m3 h 720 Med 600...

Страница 9: ... G09 12LLCB WALL MOUNTED TYPE AS G09 12LLCB DIMENSIONS 444 MODEL AS G09LLCB AS G12LLCB Unit mm 262 206 820 INSTALLATION PLACE 70 mm or more 1 500 mm or more 1 800 mm or more Wall cap 63 mm or more Wall hook bracket 100 mm or more ...

Страница 10: ... 01 07 WALL MOUNTED TYPE AS G09 12LLCB WALL MOUNTED TYPE AS G09 12LLCB WIRING DIAGRAMS 555 MODEL AS G09LLCB AS G12LLCB ...

Страница 11: ...0 69 40 1 60 1 09 0 63 1 68 1 15 0 61 1 88 1 28 0 65 2 01 1 37 0 66 2 15 1 46 0 66 2 23 1 52 0 65 2 32 1 58 0 63 43 1 35 1 06 0 57 1 44 1 06 0 57 1 63 1 06 0 59 1 72 1 06 0 59 1 82 1 06 0 58 1 94 1 06 0 58 2 06 1 06 0 57 AFR 12 0 Indoor temperature CDB 18 21 23 25 27 29 32 CWB 12 15 16 18 19 21 23 Outdoor temperature CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP 20 2 66...

Страница 12: ...1 3 34 1 01 3 24 1 03 3 15 1 06 7 6 3 70 1 01 3 65 1 01 3 60 1 00 3 51 1 05 3 41 1 10 10 8 3 83 0 99 3 77 0 99 3 71 0 99 3 62 1 01 3 53 1 04 15 10 3 95 0 97 3 89 0 97 3 82 0 97 3 73 0 97 3 64 0 97 AFR 12 3 Indoor temperature CDB 16 18 20 22 24 Outdoor temperature CDB CWB TC IP TC IP TC IP TC IP TC IP 15 16 3 01 1 54 3 04 1 57 3 07 1 59 3 04 1 58 3 00 1 57 10 11 3 73 1 64 3 68 1 66 3 62 1 68 3 59 1...

Страница 13: ... 5 2 1 0 1 2 Unit m s m m TOP VIEW Vertical flap Up Horizontal flap Center 0 1 2 3 4 5 6 7 8 2 0 1 0 1 0 0 5 0 5 3 2 1 0 1 2 3 Unit m s m TOP VIEW Vertical flap Up Horizontal flap Right Left m 0 1 2 3 4 5 6 7 8 2 0 1 0 0 5 3 2 1 0 Unit m s m SIDE VIEW Vertical flap Up Horizontal flap Center m 0 1 2 3 4 5 6 7 8 2 0 1 0 0 5 3 2 1 0 Unit m s m SIDE VIEW Vertical flap Down Horizontal flap Center m 0 1...

Страница 14: ...ber of rotations r p m Air flow HIGH 1320 720 m h 200 l s 424 CFM MED 1120 600 m h 167 l s 353 CFM LOW 840 420 m h 117 l s 247 CFM QUIET 700 325 m h 90 l s 191 CFM Fan speed Number of rotations r p m Air flow HIGH 1360 740 m h 206 l s 436 CFM MED 1120 600 m h 167 l s 353 CFM LOW 900 450 m h 125 l s 265 CFM QUIET 700 325 m h 90 l s 191 CFM ...

Страница 15: ...rotations r p m Air flow HIGH 1320 720 m h 200 l s 424 CFM MED 1120 600 m h 167 l s 353 CFM LOW 860 425 m h 118 l s 250 CFM QUIET 700 325 m h 90 l s 191 CFM Fan speed Number of rotations r p m Air flow HIGH 1360 740 m h 206 l s 436 CFM MED 1120 600 m h 167 l s 353 CFM LOW 900 450 m h 125 l s 265 CFM QUIET 700 325 m h 90 l s 191 CFM ...

Страница 16: ...dB 0dB 0 0002µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band sound pressure level dB 0dB 0 0002µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 MODEL...

Страница 17: ... 01 14 WALL MOUNTED TYPE AS G09 12LLCB WALL MOUNTED TYPE AS G09 12LLCB SOUND LEVEL CHECK POINT 88888 ...

Страница 18: ...CTERISTICS 999 Model Name ASÛG09LLCB ASÛG12LLCB Power Supply Voltage V 230 Frequency Hz 50 Max Operating Current A 0 3 Wiring Spec Connection Cable mm2 1 5 Limited wiring length m 21 Wiring Spec Selected Sample Selected based on Japan Electrotechnical Standard and Codes Committee E0005 ...

Страница 19: ... G09 12LLCB WALL MOUNTED TYPE AS G09 12LLCB SAFETY DEVICES 1111 Protection form Model ASÛG09LLCB ASÛG12LLCB Circuit protection Current fuse PCB 250V 3 15A Fan motor protection Terminal protection program OFF 160 25 C ON 110 25 C ...

Страница 20: ...s the SET TEMP 111 button to change the signal code between Match the code on the display to the air conditioner signal code initially set to If the signal code does not need to be selected press the MODE button and proceed to STEP 2 Press the MODE button to accept the signal code and proceed to STEP 2 222 1 The air conditioner signal code is set to prior to shipment Contact your retailer to chang...

Страница 21: ...rt interval 02 No indication 03 The filter sign interval time is different according to Indoor unit type as follows Setting description Compact Wall Mounted Standard 400 hours Long interval 1000 hours Short interval 200 hours 2 Cooler room temperature correction Depending on the installed environment the room temperature sensor may require a correction The settings may be selected as shown in the ...

Страница 22: ...e Yes 40 00 No 01 Auto restart is an emergency function such as for power failure etc Do not start and stop the indoor unit by this function in normal operation Be sure to operate by the control unit or external input device 5 Remote controller signal code Change the indoor unit Signal Code depending on the remote controllers Factory setting Setting description Function number Setting value A 44 0...

Страница 23: ...ir conditioner signal code Press the MODE button again The signal code will be changed 333 If no buttons are pressed within 30 seconds after the signal code is displayed the display returns to the original status In this case start again from step 1 The air conditioner signal code is set to A prior to shipment Contact your retailer to change the signal code The remote controller resets to signal c...

Страница 24: ...ALL MOUNTED TYPE AS G09 12LLCB WALL MOUNTED TYPE AS G09 12LLCB OPTIONAL PARTS 1111 Exterior Parts name Model No Summary Remote controller holder UTZ RXLA Wall or pillar mountable and holds the remote controller ...

Страница 25: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LLCB AO G12LLCB DTR_AO122E_01 2012 08 30 ...

Страница 26: ...3 REFRIGERANT CIRCUIT 02 03 4 WIRING DIAGRAMS 02 05 5 CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFERENCE 02 06 6 ADDITIONAL CHARGE CALCULATION 02 08 7 AIR FLOW 02 09 8 OPERATION NOISE 02 10 8 1 NOISE LEVEL CURVE 02 10 8 2 SOUND LEVEL CHECK POINT 02 11 9 ELECTRIC CHARACTERISTICS 02 12 10 SAFETY DEVICES 02 13 ...

Страница 27: ...rate Cooling m3 h 1 710 1 850 Heating 1 680 1 820 Type Q ty Propeller fan 1 Motor output W 26 Sound pressure level Cooling dB A 47 51 Heating 48 52 Heat exchanger type Dimensions H W D mm 650 504 18 2 650 504 18 2 350 504 18 2 Fin pitch 1 4 1 4 Rows x Stages 1 24 1 5 24 Pipe type Copper Fin type Aluminium Compressor Type Q ty Rotary 1 Motor output W 700 700 Refrigerant Type R410A Charge g 650 750 ...

Страница 28: ... or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold weather Reverse cycle model only In the area with heavy snowfall if the intake and outlet of outdoor unit is blocked with snow it might become difficult to get warm and it is likely to cause of the breakdown Please construct a canopy and a ped...

Страница 29: ... 02 03 OUTDOOR UNIT AO G09 12LLCB OUTDOOR UNIT AO G09 12LLCB REFRIGERANT CIRCUIT 333 MODEL AO G09LLCB Refrigerant pipe diameter Liquid 1 4 6 35 mm Gas 3 8 9 52 mm ...

Страница 30: ... 02 04 OUTDOOR UNIT AO G09 12LLCB OUTDOOR UNIT AO G09 12LLCB MODEL AO G12LLCB Refrigerant pipe diameter Liquid 1 4 6 35 mm Gas 3 8 9 52 mm ...

Страница 31: ... 02 05 OUTDOOR UNIT AO G09 12LLCB OUTDOOR UNIT AO G09 12LLCB WIRING DIAGRAMS 444 MODEL AO G09LLCB AO G12LLCB ...

Страница 32: ...5 10 15 Height difference H m Û1 Indoor unit is upper than outdoor unit 10 0 944 0 897 7 5 0 983 0 944 0 897 5 1 000 0 983 0 944 0 897 0 1 000 0 983 0 944 0 897 Û2 Indoor unit is under than outdoor unit 5 0 995 0 978 0 939 0 892 7 5 0 976 0 937 0 891 10 0 935 0 889 COOLING Pipe length m 5 7 5 10 15 Height difference H m Û1 Indoor unit is upper than outdoor unit 10 0 980 0 944 7 5 0 988 0 984 0 948...

Страница 33: ...ndoor unit is upper than outdoor unit 10 0 908 0 875 7 5 0 954 0 908 0 875 5 1 000 0 954 0 908 0 875 0 1 000 0 954 0 908 0 875 Û2 Indoor unit is under than outdoor unit 5 0 995 0 949 0 903 0 870 7 5 0 947 0 902 0 868 10 0 900 0 867 COOLING Pipe length m 5 7 5 10 15 Height difference H m Û1 Indoor unit is upper than outdoor unit 10 0 957 0 911 7 5 0 974 0 961 0 916 5 0 992 0 978 0 965 0 919 0 1 000...

Страница 34: ...G09LLCB Refrigerant charge z z MODEL AO G12LLCB Refrigerant charge z z Refrigerant type R410A Refrigerant amount g 650 Total pipe length m 10 or less 15 MAX 20g m Additional charge g 0 100 Refrigerant type R410A Refrigerant amount g 750 Total pipe length m 10 or less 15 MAX 20g m Additional charge g 0 100 ...

Страница 35: ...ng z z MODEL AO G12LLCB Cooling z z Heating z z Number of rotations r p m Air flow 740 1710 m3 h 475 l s 1007 CFM Number of rotations r p m Air flow 730 1680 m3 h 467 l s 989 CFM Number of rotations r p m Air flow 820 1850 m3 h 514 l s 1089 CFM Number of rotations r p m Air flow 810 1820 m3 h 506 l s 1071 CFM ...

Страница 36: ...l dB 0dB 0 0002µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating z z Octave band sound pressure level dB 0dB 0 0002µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC ...

Страница 37: ... 02 11 OUTDOOR UNIT AO G09 12LLCB OUTDOOR UNIT AO G09 12LLCB SOUND LEVEL CHECK POINT 88888 ...

Страница 38: ...ain Fuse Circuit breaker Current A 20 Power Cable mm2 1 5 3 Limited wiring length m 15 1 The maximum current is the total current of indoor unit and outdoor unit 2 Wiring Spec Selected Sample Selected based on Japan Electrotechnical Standard and Codes Committee E0005 3 Limited wiring length This is the wiring length in case voltage descent is less than 2 When the wiring length becomes long please ...

Страница 39: ...tection form Model AOÛG09LLCB AOÛG12LLCB Circuit protection Current fuse MAIN PRINTED CIRCUIT BOARD 250V 20A 250V 3 15A Fan motor protection Terminal protection program OFF 135 5 C ON 95 15 C Compressor protection Terminal protection program DISCHARGE TEMP OFF 110 C ON After 7 minutes ...